Literature DB >> 26618852

Direct Analysis of Nonvolatile Chemical Compounds on Surfaces Using a Hand-Held Mass Spectrometer with Synchronized Discharge Ionization Function.

Xiao Wang1, Xiaoyu Zhou1, Zheng Ouyang1.   

Abstract

Synchronized discharge ionization (SDI) was previously developed for hand-held mass spectrometers with discontinuous atmospheric pressure interfaces. The function of SDI has been demonstrated for analysis of volatile organic compounds in air at high sensitivity, which is attributed to the fact that ions were produced next to the ion trap mass analyzer inside the vacuum manifold. In this study, a simple sampling device was designed and fitted to a hand-held mass spectrometer to characterize its potential in direct analysis of low-volatility chemicals on surfaces. Nine chemicals of vapor pressures ranging from 10(-4) to 10(-8) Torr (at room temperature), including pesticides, illicit drugs, and explosives, were selected to evaluate and demonstrate the analytical capability of the designed system. Compounds of vapor pressures below 10(-7) Torr, such as tetryl, cocaine, and tetrahydrocannabinol (THC), have been successfully detected. Direct analysis of pesticides from fruit and explosives from a large surface area has also been demonstrated. Tandem mass analysis was performed, which helped to confirm the analyte identity as well as to improve the signal-to-noise ratio (S/N).

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26618852     DOI: 10.1021/acs.analchem.5b03356

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Microplasma Ionization of Volatile Organics for Improving Air/Water Monitoring Systems On-Board the International Space Station.

Authors:  Matthew C Bernier; Rosana M Alberici; Joel D Keelor; Prabha Dwivedi; Stephen C Zambrzycki; William T Wallace; Daniel B Gazda; Thomas F Limero; Josh M Symonds; Thomas M Orlando; Ariel Macatangay; Facundo M Fernández
Journal:  J Am Soc Mass Spectrom       Date:  2016-04-14       Impact factor: 3.109

2.  Broad spectrum infrared thermal desorption of wipe-based explosive and narcotic samples for trace mass spectrometric detection.

Authors:  Thomas P Forbes; Matthew Staymates; Edward Sisco
Journal:  Analyst       Date:  2017-08-07       Impact factor: 4.616

3.  Clinical Evaluation of a Blood Assay to Diagnose Paucibacillary Tuberculosis via Bacterial Antigens.

Authors:  Chang Liu; Christopher J Lyon; Yang Bu; Zaian Deng; Elisabetta Walters; Yan Li; Liqun Zhang; Anneke C Hesseling; Edward A Graviss; Ye Hu
Journal:  Clin Chem       Date:  2018-01-18       Impact factor: 8.327

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.