Literature DB >> 26614404

Detection of related substances in polyene phosphatidyl choline extracted from soybean and in its commercial capsule by comprehensive supercritical fluid chromatography with mass spectrometry compared with HPLC with evaporative light scattering detection.

Qikun Jiang1, Wanjun Liu1, Xiaoting Li1, Tianhong Zhang1, Yongjun Wang1, Xiaohong Liu1.   

Abstract

Supercritical fluid chromatography with tandem mass spectrometry was used to comprehensively profile polyene phosphatidyl choline (PPC) extracted from soybean. We achieved an efficient chromatographic analysis using a BEH-2EP column (3 × 100 mm(2) , 1.7 μm) with a mobile phase consisting of CO2 and a cosolvent in gradient combination at a flow rate of 1.0 mL/min. The cosolvent consisted of methanol, acetonitrile, and water (containing 10 mM ammonium acetate and 0.2% formic acid). The total single-run time was 7 min. We used this method to accurately detect ten different phospholipids (PLs) during extraction. The limits of quantification for phosphatidyl choline, lyso-phosphatidylcholine (LPC), phosphatidic acid (PA), sphingomyelin, phosphatidyl glycerol, phosphatidyl inositol (PI), cholesterol, cardiolipin, phosphatidyl serine, and phosphatidyl ethanolamine (PE) were 20.6, 19.52, 1.21, 2.38, 0.50, 2.28, 54.3, 0.60, 0.65, and 4.85 ng/mL, respectively. However, adopting the high-performance liquid chromatography with evaporative light scattering detection method issued by the China Food and Drug Administration, only PA, LPC, PE, PI, and PPC could be analyzed accurately, and the limits of quantification were 33.89, 60.5, 30.3, 10.9, and 61.79 μg/mL, respectively. The total single-run time was at the least 20 min. Consequently, the supercritical fluid chromatography with tandem mass spectrometry method was more suitable for the analysis of related PLs.
© 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  High-performance liquid chromatography; Polyene phosphatidyl choline; Related substances analysis; Supercritical fluid chromatography; Tandem mass spectrometry

Mesh:

Substances:

Year:  2015        PMID: 26614404     DOI: 10.1002/jssc.201500954

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  1 in total

1.  The studies of PLGA nanoparticles loading atorvastatin calcium for oral administration in vitro and in vivo.

Authors:  Zhenbao Li; Wenhui Tao; Dong Zhang; Chunnuan Wu; Binbin Song; Shang Wang; Tianyang Wang; Mingming Hu; Xiaohong Liu; Yongjun Wang; Yinghua Sun; Jin Sun
Journal:  Asian J Pharm Sci       Date:  2016-08-31       Impact factor: 6.598

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.