Literature DB >> 26613764

The advantages of live/real time three-dimensional transesophageal echocardiography during assessments of pulmonary stenosis.

Tuğba Kemaloğlu Öz1, Fatma Özpamuk Karadeniz2, Şükrü Akyüz2, Şennur Ünal Dayı2, Aycan Esen Zencirci2, Işıl Atasoy2, Altuğ Ösken2, Mehmet Eren2.   

Abstract

This report sought to compare live/real-time three-dimensional transesophageal echocardiography (3D-TEE) with two-dimensional transesophageal echocardiography (2D-TEE) and to determine whether there are advantages to using 3D-TEE on patients with pulmonary stenosis (PS). Sixteen consecutive adult patients (50 % male and 50 % female; mean age 33 ± 13.4 years) with PS and indications of TEE were prospectively enrolled in this study. Following this, initial 2D-TEE and 3D-TEE examinations were performed, and 3D-TEE images were analyzed using an off-line Q-lab software system. Finally, the 2D-TEE and 3D-TEE findings were compared. In the present study, 3D-TEE allowed us to obtain the en face views of pulmonary valves (PVs) in all but one patient. While this patient was without a PV due to a previous tetralogy of Fallot operation, we could detect the type of PV in the other 15 (93.7 %) patients by using 3D-TEE. Due to poor image quality, the most stenotic area was not measurable in only one (6.2 %) of the patients. In eight (50 %) of the patients, severity and localization of stenosis were more precisely determined with 3DTEE than with 2D-TEE. The PVs' maximal annulus dimensions were found to be significantly larger when they were measured using 3D modalities. This study provides evidence of the incremental value of using 3D-TEE rather than 2D-TEE during assessments of PS, specifically in cases where special conditions (pregnancy, pulmonary regurgitation, and concomitant atrial septal defects) cause recordings of the transvalvular peak gradient to be inaccurate. Therefore, 3D-TEE should be used as a complementary imaging tool to 2D-TEE during routine echocardiographic examinations.

Entities:  

Keywords:  Echocardiography; Pulmonary valve; Pulmonary valve stenosis; Three dimensional transesophageal echocardiography; Three-dimensional echocardiography; Transesophageal echocardiography

Mesh:

Year:  2015        PMID: 26613764     DOI: 10.1007/s10554-015-0811-y

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  18 in total

1.  EAE/ASE recommendations for image acquisition and display using three-dimensional echocardiography.

Authors:  Roberto M Lang; Luigi P Badano; Wendy Tsang; David H Adams; Eustachio Agricola; Thomas Buck; Francesco F Faletra; Andreas Franke; Judy Hung; Leopoldo Pérez de Isla; Otto Kamp; Jaroslaw D Kasprzak; Patrizio Lancellotti; Thomas H Marwick; Marti L McCulloch; Mark J Monaghan; Petros Nihoyannopoulos; Natesa G Pandian; Patricia A Pellikka; Mauro Pepi; David A Roberson; Stanton K Shernan; Girish S Shirali; Lissa Sugeng; Folkert J Ten Cate; Mani A Vannan; Jose Luis Zamorano; William A Zoghbi
Journal:  J Am Soc Echocardiogr       Date:  2012-01       Impact factor: 5.251

2.  ESC Guidelines for the management of grown-up congenital heart disease (new version 2010).

Authors:  Helmut Baumgartner; Philipp Bonhoeffer; Natasja M S De Groot; Fokko de Haan; John Erik Deanfield; Nazzareno Galie; Michael A Gatzoulis; Christa Gohlke-Baerwolf; Harald Kaemmerer; Philip Kilner; Folkert Meijboom; Barbara J M Mulder; Erwin Oechslin; Jose M Oliver; Alain Serraf; Andras Szatmari; Erik Thaulow; Pascal R Vouhe; Edmond Walma
Journal:  Eur Heart J       Date:  2010-08-27       Impact factor: 29.983

Review 3.  Heart valve macro- and microstructure.

Authors:  Martin Misfeld; Hans-Hinrich Sievers
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2007-08-29       Impact factor: 6.237

4.  Real-time three-dimensional transoesophageal echocardiography enables preoperative pulmonary valvulopathy assessment.

Authors:  Alfonso H Waller; Yiannis S Chatzizisis; Javid J Moslehi; Frederick Y Chen; Judy R Mangion
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2013-12-29       Impact factor: 6.875

5.  Guidelines for performing a comprehensive transesophageal echocardiographic examination: recommendations from the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists.

Authors:  Rebecca T Hahn; Theodore Abraham; Mark S Adams; Charles J Bruce; Kathryn E Glas; Roberto M Lang; Scott T Reeves; Jack S Shanewise; Samuel C Siu; William Stewart; Michael H Picard
Journal:  J Am Soc Echocardiogr       Date:  2013-09       Impact factor: 5.251

6.  Topographic Anatomy and Histology of the Valves in the Human Heart.

Authors:  L Gross; M A Kugel
Journal:  Am J Pathol       Date:  1931-09       Impact factor: 4.307

7.  Utility of live/real time three-dimensional transesophageal echocardiography in the assessment and percutaneous intervention of bioprosthetic pulmonary valve stenosis.

Authors:  Mustafa I Ahmed; Maximiliano German Amado Escañuela; William A Crosland; William S McMahon; Oluseun O Alli; Navin C Nanda
Journal:  Echocardiography       Date:  2014-03-20       Impact factor: 1.724

8.  CT and MR imaging of the pulmonary valve.

Authors:  Farhood Saremi; Atul Gera; S Yen Ho; Ziyad M Hijazi; Damián Sánchez-Quintana
Journal:  Radiographics       Date:  2014 Jan-Feb       Impact factor: 5.333

9.  Real-time three-dimensional transthoracic echocardiography in daily practice: initial experience.

Authors:  Ashraf M Anwar; Youssef F M Nosir; Siti Khairani Zainal-Abidin; Aref Ajam; Hassan Chamsi-Pasha
Journal:  Cardiovasc Ultrasound       Date:  2012-03-26       Impact factor: 2.062

10.  Three-dimensional echocardiographic views of bicuspid pulmonic valve.

Authors:  Sung Woo Cho; Byung Gyu Kim; Deok Hee Kim; Byung Ok Kim; Choong Won Goh; Kun Joo Rhee; Young Sup Byun
Journal:  J Cardiovasc Ultrasound       Date:  2014-09-29
View more
  2 in total

Review 1.  Right ventricular diastolic dysfunction and failure: a review.

Authors:  Youn-Hoa Jung; Xianfeng Ren; Giancarlo Suffredini; Jeffery M Dodd-O; Wei Dong Gao
Journal:  Heart Fail Rev       Date:  2021-05-19       Impact factor: 4.654

2.  A Misclassification of Pulmonary Stenosis Using Conventional Echocardiographic Methods.

Authors:  Tuğba Kemaloğlu Öz; Mehmet Eren; Tayfun Gürol; Özer Soylu; Bahadır Dağdeviren
Journal:  Balkan Med J       Date:  2018-01-20       Impact factor: 2.021

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.