Literature DB >> 26609408

Classification of Alzheimer's disease from quadratic sample entropy of electroencephalogram.

Samantha Simons1, Daniel Abasolo1, Javier Escudero2.   

Abstract

Currently accepted input parameter limitations in entropy-based, non-linear signal processing methods, for example, sample entropy (SampEn), may limit the information gathered from tested biological signals. The ability of quadratic sample entropy (QSE) to identify changes in electroencephalogram (EEG) signals of 11 patients with a diagnosis of Alzheimer's disease (AD) and 11 age-matched, healthy controls is investigated. QSE measures signal regularity, where reduced QSE values indicate greater regularity. The presented method allows a greater range of QSE input parameters to produce reliable results than SampEn. QSE was lower in AD patients compared with controls with significant differences (p < 0.01) for different parameter combinations at electrodes P3, P4, O1 and O2. Subject- and epoch-based classifications were tested with leave-one-out linear discriminant analysis. The maximum diagnostic accuracy and area under the receiver operating characteristic curve were 77.27 and more than 80%, respectively, at many parameter and electrode combinations. Furthermore, QSE results across all r values were consistent, suggesting QSE is robust for a wider range of input parameters than SampEn. The best results were obtained with input parameters outside the acceptable range for SampEn, and can identify EEG changes between AD patients and controls. However, caution should be applied because of the small sample size.

Entities:  

Keywords:  Alzheimer disease classification; EEG; O1 electrodes; O2 electrodes; P3 electrodes; P4 electrodes; QSE input parameters; biomedical electrodes; diseases; electroencephalogram; electroencephalography; entropy; epoch-based classifications; leave-one-out discriminant analysis; maximum diagnostic accuracy; medical signal processing; nonlinear signal processing methods; quadratic sample entropy; receiver operating characteristic curve; sensitivity analysis; signal classification; signal regularity; subject-based classifications; tested biological signals

Year:  2015        PMID: 26609408      PMCID: PMC4612311          DOI: 10.1049/htl.2014.0106

Source DB:  PubMed          Journal:  Healthc Technol Lett        ISSN: 2053-3713


  20 in total

1.  Physiological time-series analysis using approximate entropy and sample entropy.

Authors:  J S Richman; J R Moorman
Journal:  Am J Physiol Heart Circ Physiol       Date:  2000-06       Impact factor: 4.733

2.  Approximate entropy as a measure of system complexity.

Authors:  S M Pincus
Journal:  Proc Natl Acad Sci U S A       Date:  1991-03-15       Impact factor: 11.205

3.  Improved entropy rate estimation in physiological data.

Authors:  D E Lake
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

Review 4.  Nonlinear dynamical analysis of EEG and MEG: review of an emerging field.

Authors:  C J Stam
Journal:  Clin Neurophysiol       Date:  2005-10       Impact factor: 3.708

Review 5.  Assessing serial irregularity and its implications for health.

Authors:  S M Pincus
Journal:  Ann N Y Acad Sci       Date:  2001-12       Impact factor: 5.691

6.  Analysis of regularity in the EEG background activity of Alzheimer's disease patients with Approximate Entropy.

Authors:  Daniel Abásolo; Roberto Hornero; Pedro Espino; Jesús Poza; Clara I Sánchez; Ramón de la Rosa
Journal:  Clin Neurophysiol       Date:  2005-08       Impact factor: 3.708

7.  Approximate entropy and auto mutual information analysis of the electroencephalogram in Alzheimer's disease patients.

Authors:  D Abásolo; J Escudero; R Hornero; C Gómez; P Espino
Journal:  Med Biol Eng Comput       Date:  2008-09-11       Impact factor: 2.602

8.  A comparative study of synchrony measures for the early diagnosis of Alzheimer's disease based on EEG.

Authors:  J Dauwels; F Vialatte; T Musha; A Cichocki
Journal:  Neuroimage       Date:  2009-06-30       Impact factor: 6.556

Review 9.  EEG dynamics in patients with Alzheimer's disease.

Authors:  Jaeseung Jeong
Journal:  Clin Neurophysiol       Date:  2004-07       Impact factor: 3.708

10.  Entropy analysis of the EEG background activity in Alzheimer's disease patients.

Authors:  D Abásolo; R Hornero; P Espino; D Alvarez; J Poza
Journal:  Physiol Meas       Date:  2006-01-13       Impact factor: 2.833

View more
  5 in total

1.  Understanding perception of active noise control system through multichannel EEG analysis.

Authors:  Sangeeta Bagha; R K Tripathy; Pranati Nanda; C Preetam; Debi Prasad Das
Journal:  Healthc Technol Lett       Date:  2018-05-08

2.  Systematic Review on Resting-State EEG for Alzheimer's Disease Diagnosis and Progression Assessment.

Authors:  Raymundo Cassani; Mar Estarellas; Rodrigo San-Martin; Francisco J Fraga; Tiago H Falk
Journal:  Dis Markers       Date:  2018-10-04       Impact factor: 3.434

3.  EEG Characterization of the Alzheimer's Disease Continuum by Means of Multiscale Entropies.

Authors:  Aarón Maturana-Candelas; Carlos Gómez; Jesús Poza; Nadia Pinto; Roberto Hornero
Journal:  Entropy (Basel)       Date:  2019-05-28       Impact factor: 2.524

4.  Fuzzy Entropy Analysis of the Electroencephalogram in Patients with Alzheimer's Disease: Is the Method Superior to Sample Entropy?

Authors:  Samantha Simons; Pedro Espino; Daniel Abásolo
Journal:  Entropy (Basel)       Date:  2018-01-03       Impact factor: 2.524

5.  An Automated Approach for the Detection of Alzheimer's Disease From Resting State Electroencephalography.

Authors:  Eduardo Perez-Valero; Christian Morillas; Miguel A Lopez-Gordo; Ismael Carrera-Muñoz; Samuel López-Alcalde; Rosa M Vílchez-Carrillo
Journal:  Front Neuroinform       Date:  2022-07-11       Impact factor: 3.739

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.