Literature DB >> 26605132

Superior performance of cone beam tomography in detecting a calcaneus fracture.

Christian Lohse1, Philip Catala-Lehnen2, Marc Regier3, Max Heiland1.   

Abstract

Cone beam computed tomography is a state-of-the-art imaging tool, initially developed for dental and maxillofacial application. With its high resolution and low radiation dose, cone beam tomography has been expanding its application fields, for example, to diagnosis of traumata and fractures in the head and neck area. In this study, we demonstrate superior and satisfactory performance of cone beam tomography for the imaging of a calcaneus fracture in comparison to conventional X-ray and computed tomography.

Entities:  

Keywords:  calcaneus fracture; computed tomography; cone beam computed tomography; trauma

Year:  2015        PMID: 26605132      PMCID: PMC4637842          DOI: 10.3205/iprs000068

Source DB:  PubMed          Journal:  GMS Interdiscip Plast Reconstr Surg DGPW        ISSN: 2193-8091


  10 in total

1.  Deriving Hounsfield units using grey levels in cone beam CT: a clinical application.

Authors:  T E Reeves; P Mah; W D McDavid
Journal:  Dentomaxillofac Radiol       Date:  2012-06-29       Impact factor: 2.419

2.  ALARA still applies.

Authors:  Allan G Farman
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2005-10

3.  Comparison of radiation dose for implant imaging using conventional spiral tomography, computed tomography, and cone-beam computed tomography.

Authors:  Anson C M Chau; Karl Fung
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2009-01-25

4.  Cone beam CT: a current overview of devices.

Authors:  A Nemtoi; C Czink; D Haba; A Gahleitner
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

5.  Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology.

Authors:  John B Ludlow; Marija Ivanovic
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2008-05-27

6.  Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners.

Authors:  A Suomalainen; T Kiljunen; Y Käser; J Peltola; M Kortesniemi
Journal:  Dentomaxillofac Radiol       Date:  2009-09       Impact factor: 2.419

7.  Cone beam CT in dental practice.

Authors:  A Dawood; S Patel; J Brown
Journal:  Br Dent J       Date:  2009-07-11       Impact factor: 1.626

8.  The epidemiology of calcaneal fractures.

Authors:  M J Mitchell; J C McKinley; C M Robinson
Journal:  Foot (Edinb)       Date:  2009-12

Review 9.  The pathophysiology, diagnosis, and management of foot stress fractures.

Authors:  James Pegrum; Vivek Dixit; Nat Padhiar; Ian Nugent
Journal:  Phys Sportsmed       Date:  2014-11       Impact factor: 2.241

10.  [Cross-sectional imaging in dentomaxillofacial diagnostics: dose comparison of dental MSCT and NewTom 9000 DVT].

Authors:  E Coppenrath; F Draenert; U Lechel; R Veit; T Meindl; M Reiser; U Mueller-Lisse
Journal:  Rofo       Date:  2008-05
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.