Literature DB >> 26604035

Defining reference levels for intra-operative radiation exposure in orthopaedic trauma: A retrospective multicentre study.

J Hardman1, M Elvey2, N Shah3, N Simson4, S Patel5, R Anakwe6.   

Abstract

There is currently limited data to define reference levels for the use of ionising radiation in orthopaedic trauma surgery. In this multicentre study, we utilise methodology employed by the Health Protection Agency in establishing reference levels for diagnostic investigations in order to define analogous levels for common and reproducible orthopaedic trauma procedures. Four hundred ninety-five procedures were identified across four Greater London hospitals over a 1-year period. Exposure was defined in terms of both time and dose area product (DAP). Third quartile mean values for either parameter were used to define reference levels. Variations both between centres and grades of lead surgeon were analysed as secondary outcomes. Reference levels; dynamic hip screw (DHS) 1.9225000 Gycm(2)/70.50 s, intramedullary (IM) femoral nail 1.5837500 Gycm(2)/126.00 s, open reduction internal fixation (ORIF) clavicle 0.2042500 Gycm(2)/21.50 s, ORIF lateral malleolus 0.32250500 Gycm(2)/35.00 s, ORIF distal radius 0.1300000 Gycm(2)/56.00 s. Grade of surgeon did not influence exposure in dynamic hip screw, and was inversely related to exposure in intramedullary femoral nails. Less variation was observed with exposure time than with DAP. This study provides the most comprehensive reference to guide fluoroscopy use in orthopaedic trauma to date, and is of value both at the point of delivery and for audit of local practice.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Dose area product; Exposure time; Ionising radiation; Orthopaedic trauma; Reference levels

Mesh:

Year:  2015        PMID: 26604035     DOI: 10.1016/j.injury.2015.10.010

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  6 in total

1.  Patient dose reference levels in surgery: a multicenter study.

Authors:  J Greffier; C Etard; O Mares; F Pereira; D Defez; C Duverger; P Branchereau; J P Beregi; R Coulomb; A Larbi
Journal:  Eur Radiol       Date:  2018-08-01       Impact factor: 5.315

2.  [Suitability of computer-assisted femoral intramedullary nailing for control of torsion and length : Systematic review of clinical studies].

Authors:  Emmanouil Liodakis; Christian Krettek; Nael Hawi
Journal:  Unfallchirurg       Date:  2018-03       Impact factor: 1.000

3.  Establishing local diagnostic reference levels for common orthopaedic procedures using the mini C-arm fluoroscope.

Authors:  Anna Kropelnicki; Rosemary Eaton; Alexandra Adamczyk; Jacqueline Waterman; Pegah Mohaghegh
Journal:  Br J Radiol       Date:  2020-10-22       Impact factor: 3.039

4.  The Effect of C-Arm Mobility and Field of Vision on Radiation Exposure in the Treatment of Proximal Femoral Fractures: A Randomized Clinical Trial.

Authors:  Mahmut Kalem; Kerem Başarır; Hakan Kocaoğlu; Ercan Şahin; Hakan Kınık
Journal:  Biomed Res Int       Date:  2018-03-27       Impact factor: 3.411

5.  A Report on Occupational Ionizing Radiation Exposure by an Orthopedic Surgeon in a National Health-care Setting - Clinical Case Perspective.

Authors:  Abdulbaset Abosala
Journal:  J Orthop Case Rep       Date:  2018 May-Jun

6.  Typical air kerma area product values for trauma orthopaedic surgical procedures.

Authors:  Damijan Skrk; Katja Petek; Dean Pekarovic; Nejc Mekis
Journal:  Radiol Oncol       Date:  2021-01-12       Impact factor: 2.991

  6 in total