Literature DB >> 26603240

Risk factors for the hypertensive phase after implantation of a glaucoma drainage device.

Kyoung In Jung1, Chan Kee Park1.   

Abstract

PURPOSE: To investigate risk factors for the development of the hypertensive phase after implantation of the Ahmed glaucoma valve (AGV).
METHODS: A total of 128 patients who had undergone AGV implantation were included in this study. The hypertensive phase was defined as intraocular pressure (IOP) > 21 mmHg during the first 3 months after surgery. Failure was defined IOP > 21 mmHg or less than a 20% reduction from baseline on two consecutive study visits after 3 months.
RESULTS: Mean age and preoperative IOP were not different between the hypertensive and non-hypertensive groups (p = 0.054, 0.065, respectively). Axial length (AL) was significantly longer in the hypertensive group (25.2 ± 2.6 mm) than in the non-hypertensive group (23.6 ± 1.6 mm; p = 0.006). AL was correlated with postoperative IOP at 1 and 3 months postoperatively (r = 0.176, p = 0.047; r = 0.363, p < 0.001), but not at 6 months and 1 year postoperatively (p = 0.105, 0.068). Only AL was significantly associated with development of the hypertensive phase (p = 0.026) in the binary logistic regression analysis. The development of hypertensive phase was higher in the high-myopia group (95.1%) than in the non-high myopia group (79.3%; p = 0.011). The cumulative probability of success at postoperative 1 year was 96.5% in the non-high myopia group and 95.1% in the high myopia group (p = 0.784).
CONCLUSIONS: Eyes with high myopia were at the greatest risk for developing hypertension following implantation of a glaucoma drainage valve.
© 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  axial length; glaucoma drainage device implantation; high myopia; hypertensive phase

Mesh:

Year:  2015        PMID: 26603240     DOI: 10.1111/aos.12916

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  7 in total

Review 1.  [Glaucoma treatment in high myopia].

Authors:  B Voykov; J M Rohrbach
Journal:  Ophthalmologe       Date:  2019-05       Impact factor: 1.059

2.  The role of primary needle revision after Ahmed glaucoma valve (AGV) implantation.

Authors:  Maryam Yadgari; Kiana Hassanpour; Fatemeh Vafaei
Journal:  Int Ophthalmol       Date:  2020-08-27       Impact factor: 2.031

3.  Risk factors for hypertensive phase after Ahmed glaucoma valve implantation.

Authors:  Onur Özalp; Serdar İlgüy; Eray Atalay; Tülay Şimşek; Nilgün Yıldırım
Journal:  Int Ophthalmol       Date:  2021-08-22       Impact factor: 2.031

4.  Factors related to hypertensive phase after glaucoma drainage device implantation.

Authors:  Orathai Pitukcheewanont; Visanee Tantisevi; Sunee Chansangpetch; Prin Rojanapongpun
Journal:  Clin Ophthalmol       Date:  2018-08-17

5.  Surgical management of glaucoma in Fuchs uveitis syndrome: Trabeculectomy or Ahmed glaucoma valve.

Authors:  Naveed Nilforushan; Maryam Yadgari; Sayyed Amirpooya Alemzadeh
Journal:  J Curr Ophthalmol       Date:  2018-12-28

6.  Effects of aqueous suppressants and prostaglandin analogues on early wound healing after glaucoma implant surgery.

Authors:  Kyoung In Jung; Jung Eun Woo; Chan Kee Park
Journal:  Sci Rep       Date:  2019-03-27       Impact factor: 4.379

7.  Is canaloplasty with mitomycin c a safe procedure in myopic glaucoma?

Authors:  Vivienne Dooling; Alexandra Lappas; Thomas Stefan Dietlein
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-04-18       Impact factor: 3.535

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.