Literature DB >> 26603031

Headway Duo microcatheter for cerebral arteriovenous malformation embolization with n-BCA.

Jeremy J Heit1, Abigail G S Faisal1, Nicholas A Telischak1, Omar Choudhri2, Huy M Do1.   

Abstract

BACKGROUND: Cerebral arteriovenous malformations (AVMs) are uncommon vascular lesions, and hemorrhage secondary to AVM rupture results in significant morbidity and mortality. AVMs may be treated by endovascular embolization, and technical advances in microcatheter design are likely to improve the success and safety of endovascular embolization of cerebral AVMs.
OBJECTIVE: To describe our early experience with the Headway Duo microcatheter for embolization of cerebral AVMs with n-butyl-cyanoacrylate (n-BCA).
METHODS: Consecutive patients treated by endovascular embolization of a cerebral AVM with n-BCA delivered intra-arterially through the Headway Duo microcatheter (167 cm length) were identified. Patient demographic information, procedural details, and patient outcome were determined from electronic medical records.
RESULTS: Ten consecutive patients undergoing cerebral AVM embolization using n-BCA injected through the Headway Duo microcatheter were identified. Presenting symptoms included headache, hemorrhage, seizures, and weakness. Spetzler Martin grades ranged from 1 to 5, and AVMs were located in the basal ganglia (2 patients), parietal lobe (4 patients), frontal lobe (1 patient), temporal lobe (1 patient), an entire hemisphere (1 patient), and posterior fossa (1 patient). 50 arterial pedicles were embolized, and all procedures were technically successful. There was one post-procedural hemorrhage that was well tolerated by the patient, and no other complications occurred. Additional AVM treatment was performed by surgery and radiation therapy.
CONCLUSIONS: The Headway Duo microcatheter is safe and effective for embolization of cerebral AVMs using n-BCA. The trackability and high burst pressure of the Headway Duo make it an important and useful tool for the neurointerventionalist during cerebral AVM embolization. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

Entities:  

Keywords:  Arteriovenous Malformation; Catheter; Liquid Embolic Material

Mesh:

Substances:

Year:  2015        PMID: 26603031     DOI: 10.1136/neurintsurg-2015-012094

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  1 in total

1.  Super-selective coil embolization of a basilar perforator artery aneurysm previously treated by the stent-in-stent technique, using an extremely soft bare coil delivered through a one-marker microcatheter.

Authors:  Yves Chau; Marina Sachet; Jacques Sédat
Journal:  Interv Neuroradiol       Date:  2017-07-20       Impact factor: 1.610

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.