Literature DB >> 26601710

Online eluent-switching technique coupled anion-exchange liquid chromatography–ion trap tandem mass spectrometry for analysis of non-steroidal anti-inflammatory drugs in pig serum.

Kai Chun Chang1, Jyh Shiun Lin2, Cheanyeh Cheng3.   

Abstract

A novel method for online extraction, pH-gradient separation, and analysis of nine non-steroidal anti-inflammatory drugs (NSAIDs) was developed by coupling online eluent-switching technique to single anion-exchange chromatographic column/ion trap mass spectrometer (MS) and used for monitoring NSAIDs residues in pig serum. A neutral eluent and a pH-gradient eluent were used for extraction and separation of NSAIDs, respectively. Each of nine NSAIDs has an MS precursor ion of either [M−H]− or [M−Na]−. The extracted ion chromatogram for a specific product ion of each NSAID was used for its quantitative analysis. The dynamic linear ranges of calibration curves were all 0–200 ng mL−1 (R2 > 0.9950). The analysis accuracies estimated by spiking standard concentrations at 20, 100, and 200 ng mL−1 were 80.5–99.9%. The corresponding intra-day and inter-day precisions (RSD%) were 2.5–14.5% and 2.9–15.2%, respectively. The limit of detection/limit of quantitation of NSAIDs were 1.3/4.3, 0.5/1.6, 0.2/0.5, 2.5/8.2, 1.5/4.9, 0.6/2.1, 0.6/2.0, 0.5/1.7, and 0.6/2.1 ng mL−1 for carprofen, diclofenac, flunixin, ibuprofen, ketoprofen, meclofenamic acid sodium, mefenamic acid, niflumic acid, and tolfenamic acid, respectively. After 1 h injection of a dose containing 2 mg kg−1 weight pig of flunixin and tolfenamic acid to the pigs, a residue amount of 3480 ± 36 ng mL−1 and 431 ± 13 ng mL−1, respectively, was reached for the incurred pig serum specimens and both residues were reduced to about 20 ng mL−1 at the time of 24 h.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26601710     DOI: 10.1016/j.chroma.2015.10.033

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Comprehensive two-dimensional ion chromatography (2D-IC) coupled to a post-column photochemical fluorescence detection system for determination of neonicotinoids (imidacloprid and clothianidin) in food samples.

Authors:  Nadeem Muhammad; Fenglian Wang; Qamar Subhani; Qiming Zhao; Muhammad Abdul Qadir; Hairong Cui; Yan Zhu
Journal:  RSC Adv       Date:  2018-03-02       Impact factor: 4.036

2.  Spectrophotometric Methods for Simultaneous Determination of Oxytetracycline HCl and Flunixin Meglumine in Their Veterinary Pharmaceutical Formulation.

Authors:  Hanan A Merey; Mahmmoud S Abd-Elmonem; Hagar N Nazlawy; Hala E Zaazaa
Journal:  J Anal Methods Chem       Date:  2017-07-24       Impact factor: 2.193

  2 in total