Literature DB >> 26600393

Quantification of the Mass and Viscoelasticity of Interfacial Films on Tin Anodes Using EQCM-D.

Zhenzhen Yang, Matthew C Dixon1, Robert A Erck, Lynn Trahey.   

Abstract

Electrochemical quartz crystal microbalance coupled with dissipation (EQCM-D) is employed to investigate the solid electrolyte interphase (SEI) formation and Li insertion/deinsertion into thin film electrodes of tin. Based on the frequency change we find that the initial SEI formation process is rapid before Li insertion but varies significantly with increasing concentration of the additive fluoroethylene carbonate (FEC) in the electrolyte. The extent of dissipation, which represents the film rigidity, increases with cycle number, reflecting film thickening and softening. Dissipation values are almost twice as large in the baseline electrolyte (1.2 M LiPF6 in 3:7 wt % ethylene carbonate:ethyl methyl carbonate), indicating the film in baseline electrolyte is roughly twice as soft as in the FEC-containing cells. More importantly, we detail how quantitative data about mass, thickness, shear elastic modulus, and shear viscosity in a time-resolved manner can be obtained from the EQCM-D response. These parameters were extracted from the frequency and dissipation results at multiple harmonics using the Sauerbrey and Voigt viscoelastic models. From these modeled results we show the dynamic mass changes for each half cycle. We also demonstrate that different amounts of FEC additive influence the SEI formation behavior and result in differences in the estimated mass, shear modulus and viscosity. After three cycles, the film in baseline electrolyte exhibits a 1.2 times larger mass change compared with the film in the FEC-containing electrolyte. The shear elastic modulus of films formed in the presence of FEC is larger than in the baseline electrolyte at early stages of lithiation. Also with lithiation is a marked increase in film viscosity, which together point to a much stiffer and more homogeneous SEI formed in the presence of FEC.

Entities:  

Keywords:  EQCM-D; FEC additive; SEI viscoelasticity; Voigt model; electrochemical quartz crystal microbalance; tin anode

Year:  2015        PMID: 26600393     DOI: 10.1021/acsami.5b07966

Source DB:  PubMed          Journal:  ACS Appl Mater Interfaces        ISSN: 1944-8244            Impact factor:   9.229


  4 in total

1.  Direct, operando observation of the bilayer solid electrolyte interphase structure: Electrolyte reduction on a non-intercalating electrode.

Authors:  Christopher H Lee; Joseph A Dura; Amy LeBar; Steven C DeCaluwe
Journal:  J Power Sources       Date:  2019       Impact factor: 9.127

2.  In situ real-time gravimetric and viscoelastic probing of surface films formation on lithium batteries electrodes.

Authors:  Vadim Dargel; Netanel Shpigel; Sergey Sigalov; Prasant Nayak; Mikhael D Levi; Leonid Daikhin; Doron Aurbach
Journal:  Nat Commun       Date:  2017-11-09       Impact factor: 14.919

3.  Effect of Electrode Thickness on Quality Factor of Ring Electrode QCM Sensor.

Authors:  Zhenfang Wei; Jianguo Hu; Yuanyuan Li; Jing Chen
Journal:  Sensors (Basel)       Date:  2022-07-09       Impact factor: 3.847

4.  Electrocatalytic synthesis of adipic acid coupled with H2 production enhanced by a ligand modification strategy.

Authors:  Zhenhua Li; Xiaofan Li; Hua Zhou; Yan Xu; Si-Min Xu; Yue Ren; Yifan Yan; Jiangrong Yang; Kaiyue Ji; Li Li; Ming Xu; Mingfei Shao; Xianggui Kong; Xiaoming Sun; Haohong Duan
Journal:  Nat Commun       Date:  2022-08-25       Impact factor: 17.694

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.