Literature DB >> 26597463

Changes in proximal contact tightness between fixed implant prostheses and adjacent teeth: A 1-year prospective study.

Shuxin Ren1, Ye Lin2, Xiulian Hu3, Ying Wang1.   

Abstract

STATEMENT OF PROBLEM: No study has evaluated consecutive changes in proximal contact tightness (PCT) between fixed implant prostheses and adjacent teeth after delivery.
PURPOSE: The purpose of this clinical study was to investigate consecutive biological changes in PCT between fixed implant prostheses and adjacent teeth after placement.
MATERIAL AND METHODS: Eighteen participants who had been treated with a single first molar implant in the mandible were included. Mesial and distal PCT were measured using the custom-made contact pressure system at immediate crown delivery (T0), 3-month follow-up (T1), and 1-year follow-up (T2). The PCT of natural teeth in the mesial direction of the same quadrant was also measured at T2 as a control. Repeated-measures analysis of variance (ANOVA) and 1-way ANOVA were used for statistical analysis.
RESULTS: At T0, the PCT between fixed implant prostheses and adjacent teeth was designed deliberately to be higher than the PCT between natural teeth. Using multivariate analyses, the PCT between fixed implant prostheses and adjacent teeth decreased between T0 and T1 (P<.001), while there was no significant difference between T1 and T2 (P=.506). At T2, the distal PCT was tighter than the mesial PCT (P<.001); however, no statistical difference was found in the PCT between the implant-supported restoration and the natural teeth.
CONCLUSIONS: PCT decreased significantly at both mesial and distal sites over time. The major changes occurred over the 3-month period after crown delivery.
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26597463     DOI: 10.1016/j.prosdent.2015.08.018

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  Advancing Discontinuous Fiber-Reinforced Composites above Critical Length for Replacing Current Dental Composites and Amalgam.

Authors:  Richard C Petersen
Journal:  J Nat Sci       Date:  2017-02

2.  Proximal contact alterations between implant-supported restorations and adjacent teeth in the posterior region: A 3-month prospective study.

Authors:  Solange Mehanna; Pascale Habre-Hallage
Journal:  J Clin Exp Dent       Date:  2021-05-01

3.  Proximal contact loss between implant prostheses and adjacent natural teeth: A qualitative systematic review of prevalence, influencing factors and implications.

Authors:  Jaafar Abduo; Douglas Lau
Journal:  Heliyon       Date:  2022-08-01

4.  A Single-Center Study of a Resin Inlay Dental Implant-Fixed Prosthesis for Closing Proximal Contact Loss in 89 Patients Who Underwent 3-Year Follow-Up.

Authors:  Qiyue Chen; Yong Shi; Zhaoqiang Zhang; Guangbao Song
Journal:  Med Sci Monit       Date:  2021-10-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.