Literature DB >> 26596361

The feasibility of a custom-made endoprosthesis in mandibular reconstruction: Implant design and finite element analysis.

Manuel Pinheiro1, J L Alves2.   

Abstract

This work studies the feasibility of custom-made endoprosthesis in the reconstruction of major mandibular defects. The natural anatomical and occlusal relations are used to accurately reconstruct a mandibular defect. The customized implant allows the accurate restoration of the facial profile and aesthetics. The biomechanical behaviour of mandibular endoprosthesis was validated with Finite Element Analysis for three masticatory tasks, namely incisal, right molar and left group clenching. The implanted mandible shows displacement fields and stress distributions very similar to the intact mandible. The strain fields observed along the bone-implant interface may promote bone maintenance and ingrowth. The preliminary results show that this implant may be a reliable alternative to other prosthetic mandibular reconstruction approaches.
Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

Keywords:  Cephalometry; Endosseous implantation; Finite element analysis; Mandibular prosthesis implantation; Mandibular reconstruction

Mesh:

Substances:

Year:  2015        PMID: 26596361     DOI: 10.1016/j.jcms.2015.10.004

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  5 in total

1.  Design Criteria for Patient-specific Mandibular Continuity Defect Reconstructed Implant with Lightweight Structure using Weighted Topology Optimization and Validated with Biomechanical Fatigue Testing.

Authors:  Chun-Li Lin; Yu-Tzu Wang; Chun-Ming Chang; Cheng-Hsien Wu; Wei-Heng Tsai
Journal:  Int J Bioprint       Date:  2021-12-10

2.  New insights into the biomechanics of Legg-Calvé-Perthes' disease: The Role of Epiphyseal Skeletal Immaturity in Vascular Obstruction.

Authors:  M Pinheiro; C A Dobson; D Perry; M J Fagan
Journal:  Bone Joint Res       Date:  2018-02       Impact factor: 5.853

3.  A 3D cephalometric protocol for the accurate quantification of the craniofacial symmetry and facial growth.

Authors:  Manuel Pinheiro; Xinhui Ma; Michael J Fagan; Grant T McIntyre; Ping Lin; Gautham Sivamurthy; Peter A Mossey
Journal:  J Biol Eng       Date:  2019-05-17       Impact factor: 4.355

4.  The effect of fixation plate use on bone healing during the reconstruction of mandibular defects.

Authors:  Khang Do Gia Hong; Seong-Gon Kim; Young-Wook Park
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2019-10-30

5.  Biomechanical evaluation of the human mandible after temporomandibular joint replacement under different biting conditions.

Authors:  Manuel Pinheiro; Robin Willaert; Afaq Khan; Anouar Krairi; Wim Van Paepegem
Journal:  Sci Rep       Date:  2021-07-07       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.