This paper presents a novel plug-in nanoliter liquid dispensing system with a plug-and-play interface for simple and reversible, yet robust integration of the dispenser. A plug-in type dispenser was developed to facilitate assembly and disassembly with an actuating part through efficient modularization. The entire process for assembly and operation of the plug-in dispenser is performed via the plug-and-play interface in less than a minute without loss of dispensing quality. The minimum volume of droplets pneumatically dispensed using the plug-in dispenser was 124 nl with a coefficient of variation of 1.6%. The dispensed volume increased linearly with the nozzle size. Utilizing this linear relationship, two types of multinozzle dispensers consisting of six parallel channels (emerging from an inlet) and six nozzles were developed to demonstrate a novel strategy for volume gradient dispensing at a single operating condition. The droplet volume dispensed from each nozzle also increased linearly with nozzle size, demonstrating that nozzle size is a dominant factor on dispensed volume, even for multinozzle dispensing. Therefore, the proposed plug-in dispenser enables flexible design of nozzles and reversible integration to dispense droplets with different volumes, depending on the application. Furthermore, to demonstrate the practicality of the proposed dispensing system, we developed a pencil-type dispensing system as an alternative to a conventional pipette for rapid and reliable dispensing of minute volume droplets.

Year:  2015        PMID: 26594263      PMCID: PMC4644146          DOI: 10.1063/1.4935937

Source DB:  PubMed          Journal:  Biomicrofluidics        ISSN: 1932-1058            Impact factor:   2.800


  8 in total

1.  Standards for connecting microfluidic devices?

Authors:  Henne van Heeren
Journal:  Lab Chip       Date:  2012-02-02       Impact factor: 6.799

2.  Fit-to-Flow (F2F) interconnects: universal reversible adhesive-free microfluidic adaptors for lab-on-a-chip systems.

Authors:  Arnold Chen; Tingrui Pan
Journal:  Lab Chip       Date:  2010-11-25       Impact factor: 6.799

3.  Chemically etched open tubular and monolithic emitters for nanoelectrospray ionization mass spectrometry.

Authors:  Ryan T Kelly; Jason S Page; Quanzhou Luo; Ronald J Moore; Daniel J Orton; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2006-11-15       Impact factor: 6.986

4.  Manipulating and dispensing micro/nanoliter droplets by superhydrophobic needle nozzles.

Authors:  Zhichao Dong; Jie Ma; Lei Jiang
Journal:  ACS Nano       Date:  2013-10-16       Impact factor: 15.881

5.  Evaluation of a liquid dispenser for assay development and enzymology in 1536-well format.

Authors:  Heike Butendeich; Noëlle M Pierret; Shin Numao
Journal:  J Lab Autom       Date:  2013-01-25

6.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane).

Authors:  D C Duffy; J C McDonald; O J Schueller; G M Whitesides
Journal:  Anal Chem       Date:  1998-12-01       Impact factor: 6.986

7.  Inkjet printing methodologies for drug screening.

Authors:  Giuseppe Arrabito; Bruno Pignataro
Journal:  Anal Chem       Date:  2010-04-15       Impact factor: 6.986

8.  Inkjet metrology: high-accuracy mass measurements of microdroplets produced by a drop-on-demand dispenser.

Authors:  R Michael Verkouteren; Jennifer R Verkouteren
Journal:  Anal Chem       Date:  2009-10-15       Impact factor: 6.986

  8 in total
  3 in total

1.  Dotette: Programmable, high-precision, plug-and-play droplet pipetting.

Authors:  Jinzhen Fan; Yongfan Men; Kuo Hao Tseng; Yi Ding; Yunfeng Ding; Fernando Villarreal; Cheemeng Tan; Baoqing Li; Tingrui Pan
Journal:  Biomicrofluidics       Date:  2018-05-21       Impact factor: 2.800

2.  Microfluidic cap-to-dispense (μCD): a universal microfluidic-robotic interface for automated pipette-free high-precision liquid handling.

Authors:  Jingjing Wang; Ka Deng; Chuqing Zhou; Zecong Fang; Conary Meyer; Kaustubh Umesh-Anjali Deshpande; Zhihao Li; Xianqiang Mi; Qian Luo; Bruce D Hammock; Cheemeng Tan; Yan Chen; Tingrui Pan
Journal:  Lab Chip       Date:  2019-10-09       Impact factor: 6.799

3.  Deterministic bead-in-droplet ejection utilizing an integrated plug-in bead dispenser for single bead-based applications.

Authors:  Hojin Kim; In Ho Choi; Sanghyun Lee; Dong-Joon Won; Yong Suk Oh; Donghoon Kwon; Hyung Jin Sung; Sangmin Jeon; Joonwon Kim
Journal:  Sci Rep       Date:  2017-04-10       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.