Literature DB >> 26593773

Computationally Optimizing the Compliance of a Biopolymer Based Tissue Engineered Vascular Graft.

Scott Harrison, Ehab Tamimi, Josh Uhlorn, Tim Leach, Jonathan P Vande Geest.   

Abstract

Coronary heart disease is a leading cause of death among Americans for which coronary artery bypass graft (CABG) surgery is a standard surgical treatment. The success of CABG surgery is impaired by a compliance mismatch between vascular grafts and native vessels. Tissue engineered vascular grafts (TEVGs) have the potential to be compliance matched and thereby reduce the risk of graft failure. Glutaraldehyde (GLUT) vapor-crosslinked gelatin/fibrinogen constructs were fabricated and mechanically tested in a previous study by our research group at 2, 8, and 24 hrs of GLUT vapor exposure. The current study details a computational method that was developed to predict the material properties of our constructs for crosslinking times between 2 and 24 hrs by interpolating the 2, 8, and 24 hrs crosslinking time data. matlab and abaqus were used to determine the optimal combination of fabrication parameters to produce a compliance matched construct. The validity of the method was tested by creating a 16-hr crosslinked construct of 130 μm thickness and comparing its compliance to that predicted by the optimization algorithm. The predicted compliance of the 16-hr construct was 0.00059 mm Hg-1 while the experimentally determined compliance was 0.00065 mm Hg-1, a relative difference of 9.2%. Prior data in our laboratory has shown the compliance of the left anterior descending porcine coronary (LADC) artery to be 0.00071 ± 0.0003 mm Hg-1. Our optimization algorithm predicts that a 258-μm-thick construct that is GLUT vapor crosslinked for 8.1 hrs would match LADC compliance. This result is consistent with our previous work demonstrating that an 8-hr GLUT vapor crosslinked construct produces a compliance that is not significantly different from a porcine coronary LADC.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26593773      PMCID: PMC4845160          DOI: 10.1115/1.4032060

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  18 in total

1.  Electrospinning collagen and elastin: preliminary vascular tissue engineering.

Authors:  Eugene D Boland; Jamil A Matthews; Kristin J Pawlowski; David G Simpson; Gary E Wnek; Gary L Bowlin
Journal:  Front Biosci       Date:  2004-05-01

2.  Biomechanical Comparison of Glutaraldehyde-Crosslinked Gelatin Fibrinogen Electrospun Scaffolds to Porcine Coronary Arteries.

Authors:  E Tamimi; D C Ardila; D G Haskett; T Doetschman; M J Slepian; R S Kellar; J P Vande Geest
Journal:  J Biomech Eng       Date:  2016-01       Impact factor: 2.097

3.  Hemodynamic simulation of vascular prosthesis altering pulse wave propagation.

Authors:  J Chung; J K-J Li
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2004

4.  Heart disease and stroke statistics--2014 update: a report from the American Heart Association.

Authors:  Alan S Go; Dariush Mozaffarian; Véronique L Roger; Emelia J Benjamin; Jarett D Berry; Michael J Blaha; Shifan Dai; Earl S Ford; Caroline S Fox; Sheila Franco; Heather J Fullerton; Cathleen Gillespie; Susan M Hailpern; John A Heit; Virginia J Howard; Mark D Huffman; Suzanne E Judd; Brett M Kissela; Steven J Kittner; Daniel T Lackland; Judith H Lichtman; Lynda D Lisabeth; Rachel H Mackey; David J Magid; Gregory M Marcus; Ariane Marelli; David B Matchar; Darren K McGuire; Emile R Mohler; Claudia S Moy; Michael E Mussolino; Robert W Neumar; Graham Nichol; Dilip K Pandey; Nina P Paynter; Matthew J Reeves; Paul D Sorlie; Joel Stein; Amytis Towfighi; Tanya N Turan; Salim S Virani; Nathan D Wong; Daniel Woo; Melanie B Turner
Journal:  Circulation       Date:  2013-12-18       Impact factor: 29.690

5.  Electrospun vascular grafts with improved compliance matching to native vessels.

Authors:  Roya M Nezarati; Michelle B Eifert; David K Dempsey; Elizabeth Cosgriff-Hernandez
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2014-05-21       Impact factor: 3.368

6.  Differences in the microstructure and biomechanical properties of the recurrent laryngeal nerve as a function of age and location.

Authors:  Megan J Williams; Urs Utzinger; Julie M Barkmeier-Kraemer; Jonathan P Vande Geest
Journal:  J Biomech Eng       Date:  2014-08       Impact factor: 2.097

7.  Altered tissue behavior of a non-aneurysmal descending thoracic aorta in the mouse model of Marfan syndrome.

Authors:  Darren Haskett; Jefferson J Doyle; Connie Gard; Hwudaurw Chen; Corbie Ball; Mark A Estabrook; Alejandra C Encinas; Harry C Dietz; Urs Utzinger; Jonathan P Vande Geest; Mohamad Azhar
Journal:  Cell Tissue Res       Date:  2011-11-22       Impact factor: 5.249

8.  Design and demonstration of a microbiaxial optomechanical device for multiscale characterization of soft biological tissues with two-photon microscopy.

Authors:  Joseph T Keyes; Stacy M Borowicz; Jacob H Rader; Urs Utzinger; Mohamad Azhar; Jonathan P Vande Geest
Journal:  Microsc Microanal       Date:  2011-04       Impact factor: 4.127

9.  The effects of angiotensin II on the coupled microstructural and biomechanical response of C57BL/6 mouse aorta.

Authors:  Darren Haskett; Erin Speicher; Marie Fouts; Doug Larson; Mohamad Azhar; Urs Utzinger; Jonathan Vande Geest
Journal:  J Biomech       Date:  2011-12-23       Impact factor: 2.712

10.  Comparisons of planar and tubular biaxial tensile testing protocols of the same porcine coronary arteries.

Authors:  Joseph T Keyes; Danielle R Lockwood; Urs Utzinger; Leonardo G Montilla; Russell S Witte; Jonathan P Vande Geest
Journal:  Ann Biomed Eng       Date:  2012-11-07       Impact factor: 3.934

View more
  9 in total

1.  Fabricating mechanically improved silk-based vascular grafts by solution control of the gel-spinning process.

Authors:  Maria Rodriguez; Jonathan A Kluge; Daniel Smoot; Matthew A Kluge; Daniel F Schmidt; Christopher R Paetsch; Peter S Kim; David L Kaplan
Journal:  Biomaterials       Date:  2019-10-23       Impact factor: 12.479

2.  Computationally optimizing the compliance of multilayered biomimetic tissue engineered vascular grafts.

Authors:  Ehab Akram Tamimi; Diana Catalina Ardila; Burt D Ensley; Robert S Kellar; Jonathan Vande Geest
Journal:  J Biomech Eng       Date:  2019-02-19       Impact factor: 2.097

3.  Stress Analysis-Driven Design of Bilayered Scaffolds for Tissue-Engineered Vascular Grafts.

Authors:  Jason M Szafron; Christopher K Breuer; Yadong Wang; Jay D Humphrey
Journal:  J Biomech Eng       Date:  2017-12-01       Impact factor: 2.097

Review 4.  Building Blood Vessels with Vascular Progenitor Cells.

Authors:  Thomas Colunga; Stephen Dalton
Journal:  Trends Mol Med       Date:  2018-05-22       Impact factor: 11.951

5.  Modulating smooth muscle cell response by the release of TGFβ2 from tubular scaffolds for vascular tissue engineering.

Authors:  D C Ardila; E Tamimi; T Doetschman; W R Wagner; J P Vande Geest
Journal:  J Control Release       Date:  2019-02-20       Impact factor: 9.776

6.  In vivo development of tissue engineered vascular grafts: a fluid-solid-growth model.

Authors:  Marcos Latorre; Jason M Szafron; Abhay B Ramachandra; Jay D Humphrey
Journal:  Biomech Model Mechanobiol       Date:  2022-02-18

7.  Acute Elution of TGFβ2 Affects the Smooth Muscle Cells in a Compliance-Matched Vascular Graft.

Authors:  Kenneth J Furdella; Shinichi Higuchi; Kang Kim; Tom Doetschman; William R Wagner; Jonathan P Vande Geest
Journal:  Tissue Eng Part A       Date:  2022-07       Impact factor: 4.080

8.  Spontaneous reversal of stenosis in tissue-engineered vascular grafts.

Authors:  Joseph D Drews; Victoria K Pepper; Cameron A Best; Jason M Szafron; John P Cheatham; Andrew R Yates; Kan N Hor; Jacob C Zbinden; Yu-Chun Chang; Gabriel J M Mirhaidari; Abhay B Ramachandra; Shinka Miyamoto; Kevin M Blum; Ekene A Onwuka; Jason Zakko; John Kelly; Sharon L Cheatham; Nakesha King; James W Reinhardt; Tadahisa Sugiura; Hideki Miyachi; Yuichi Matsuzaki; Julie Breuer; Eric D Heuer; T Aaron West; Toshihiro Shoji; Darren Berman; Brian A Boe; Jeremy Asnes; Mark Galantowicz; Goki Matsumura; Narutoshi Hibino; Alison L Marsden; Jordan S Pober; Jay D Humphrey; Toshiharu Shinoka; Christopher K Breuer
Journal:  Sci Transl Med       Date:  2020-04-01       Impact factor: 17.956

9.  In-vivo assessment of a tissue engineered vascular graft computationally optimized for target vessel compliance.

Authors:  Kenneth J Furdella; Shinichi Higuchi; Ali Behrangzade; Kang Kim; William R Wagner; Jonathan P Vande Geest
Journal:  Acta Biomater       Date:  2021-01-20       Impact factor: 8.947

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.