Effect of a broad-spectrum LED curing light on the Knoop microhardness of four posterior resin based composites at 2, 4 and 6-mm depths.

Maan M ALShaafi1, Thomas Haenel2, Braden Sullivan3, Daniel Labrie4, Mohammed Q Alqahtani1, Richard B Price5.   

Abstract

OBJECTIVE: To measure the Knoop microhardness at the bottom of four posterior resin-based composites (RBCs): Tetric EvoCeram Bulk Fill (Ivoclar Vivadent), SureFil SDR flow (DENTSPLY), SonicFill (Kerr), and x-tra fil (Voco).
METHODS: The RBCs were expressed into metal rings that were 2, 4, or 6-mm thick with a 4-mm internal diameter at 30°C. The uncured specimens were covered by a Mylar strip and a Bluephase 20i (Ivoclar Vivadent) polywave(®) LED light-curing unit was used in high power setting for 20s. The specimens were then removed and placed immediately on a Knoop microhardness-testing device and the microhardness was measured at 9 points across top and bottom surfaces of each specimen. Five specimens were made for each condition.
RESULTS: As expected, for each RBC there was no significant difference in the microhardness values at the top of the 2, 4 and 6-mm thick specimens. SureFil SDR Flow was the softest resin, but was the only resin that had no significant difference between the KHN values at the bottom of the 2 and 4-mm (Mixed Model ANOVA p<0.05). Although the KHN of SureFil SDR Flow was only marginally significantly different between the 2 and 6-mm thickness, the bottom at 6-mm was only 59% of the hardness measured at the top. CLINICAL SIGNIFICANCE: This study highlights that clinicians need to consider how the depth of cure was evaluated when determining the depth of cure. SureFil SDR Flow was the softest material and, in accordance with manufacturer's instructions, this RBC should be overlaid with a conventional resin.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Broad spectrum LED curing light; Bulk fill resin based composites; Depth of cure; Knoop microhardness

Mesh:

Substances:

Year:  2015        PMID: 26593741     DOI: 10.1016/j.jdent.2015.11.004

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  3 in total

1.  The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites.

Authors:  Matej Par; Igor Repusic; Hrvoje Skenderovic; Ognjen Milat; Jelena Spajic; Zrinka Tarle
Journal:  Clin Oral Investig       Date:  2019-01-28       Impact factor: 3.573

2.  The Effect of Shade and Thickness on the Depth of Cure of Bulk-Fill Composites with Different Viscosities.

Authors:  Maryam Novin Rooz; Atefeh Yousefi Jordehi
Journal:  J Dent (Shiraz)       Date:  2020-12

3.  Effect of Light Curing Distance on Microhardness Profiles of Bulk-Fill Resin Composites.

Authors:  Fatin A Hasanain; Hani M Nassar; Reem A Ajaj
Journal:  Polymers (Basel)       Date:  2022-01-28       Impact factor: 4.329

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.