Literature DB >> 26592620

Miniaturized metal oxide pH sensors for bacteria detection.

Naroa Uria1, Natalia Abramova2, Andrey Bratov3, Francesc-Xavier Muñoz-Pascual3, Eva Baldrich4.   

Abstract

It is well known that the metabolic activity of some microorganisms results in changes of pH of the culture medium, a phenomenon that can be used for detection and quantification of bacteria. However, conventional glass electrodes that are commonly used for pH measurements are bulky, fragile and expensive, which hinders their application in miniaturized systems and encouraged to the search for alternatives. In this work, two types of metal oxide pH sensors have been tested to detect the metabolic activity of the bacterium Escherichia coli (E. coli). These pH sensors were produced on silicon chips with platinum metal contacts, onto which thin layers of IrOx or Ta2O5 were incorporated by two different methods (electrodeposition and e-beam sputtering, respectively). In order to facilitate measurement in small sample volumes, an Ag/AgCl pseudo-reference was also screen-printed in the chip and was assayed in parallel to an external Ag/AgCl reference electrode. As it is shown, the developed sensors generated results indistinguishable from those provided by a conventional glass pH-electrode but could be operated in significantly smaller sample volumes. After optimization of the detection conditions, the metal oxide sensors are successfully applied for detection of increasing concentrations of viable E. coli, with detection of less than 10(3)cfu mL(-1) in undiluted culture medium in just 5h.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bacterial viability; E. coli detection; Iridium oxide pH sensor; Microelectrodes; Tantalum pH sensor

Mesh:

Substances:

Year:  2015        PMID: 26592620     DOI: 10.1016/j.talanta.2015.10.011

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Fabrication of a Miniature Multi-Parameter Sensor Chip for Water Quality Assessment.

Authors:  Bo Zhou; Chao Bian; Jianhua Tong; Shanhong Xia
Journal:  Sensors (Basel)       Date:  2017-01-14       Impact factor: 3.576

2.  PANI/TiO2 nanocomposite-based chemiresistive gas sensor for the detection of E. Coli bacteria.

Authors:  Chaitra Venkatachalaiah; Uma Venkataraman; Raja Sellappan
Journal:  IET Nanobiotechnol       Date:  2020-12       Impact factor: 1.847

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.