Literature DB >> 26588986

Clinical value of cardiovascular magnetic resonance in patients with MR-conditional pacemakers.

Claire E Raphael1, Vassilis Vassiliou2, Francisco Alpendurada2, Sanjay K Prasad2, Dudley J Pennell2, Raad H Mohiaddin2.   

Abstract

AIMS: Magnetic resonance (MR) conditional pacemakers are increasingly implanted into patients who may need cardiovascular MR (CMR) subsequent to device implantation. We assessed the added value of CMR for diagnosis and management in this population. METHODS AND
RESULTS: CMR and pacing data from consecutive patients with MR conditional pacemakers were retrospectively reviewed. Images were acquired at 1.5 T (Siemens Magnetom Avanto). The indication for CMR and any resulting change in management was recorded. The quality of CMR was rated by an observer blinded to clinical details, and data on pacemaker and lead parameters were collected pre- and post-CMR. Seventy-two CMR scans on 69 patients performed between 2011 and 2015 were assessed. All scans were completed successfully with no significant change in lead thresholds or pacing parameters. Steady-state free precession (SSFP) cine imaging resulted in a greater frequency of non-diagnostic imaging (22 vs. 1%, P < 0.01) compared with gradient echo sequences (GRE). Right-sided pacemakers were associated with less artefact than left-sided pacemakers. Late gadolinium enhancement imaging was performed in 59 scans with only 2% of segments rated of non-diagnostic quality. The CMR data resulted in a new diagnosis in 27 (38%) of examinations; clinical management was changed in a further 18 (25%).
CONCLUSIONS: CMR in patients with MR conditional pacemakers provided diagnostic or management-changing information in the majority (63%) of our cohort. The use of gradient echo cine sequences can reduce rates of non-diagnostic imaging. Right-sided device implantation may be considered in patients likely to require CMR examination. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2015. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  CMR; PPM; cardiovascular magnetic resonance; conditional; pacemaker

Mesh:

Year:  2015        PMID: 26588986      PMCID: PMC5964714          DOI: 10.1093/ehjci/jev305

Source DB:  PubMed          Journal:  Eur Heart J Cardiovasc Imaging        ISSN: 2047-2404            Impact factor:   6.875


  30 in total

1.  Assessment of aortic root dimensions in patients with suspected Marfan syndrome: intraindividual comparison of contrast-enhanced and non-contrast magnetic resonance angiography with echocardiography.

Authors:  Peter Bannas; Michael Groth; Meike Rybczynski; Sara Sheikhzadeh; Yskert von Kodolitsch; Joachim Graessner; Gunnar Lund; Gerhard Adam; Christian R Habermann
Journal:  Int J Cardiol       Date:  2012-01-10       Impact factor: 4.164

2.  Can cardiac pacemakers and magnetic resonance imaging systems co-exist?

Authors:  Edward T Martin
Journal:  Eur Heart J       Date:  2005-01-17       Impact factor: 29.983

Review 3.  Interventional electrophysiology and cardiac resynchronization therapy: delivering electrical therapies for heart failure.

Authors:  J David Burkhardt; Bruce L Wilkoff
Journal:  Circulation       Date:  2007-04-24       Impact factor: 29.690

4.  ACR guidance document on MR safe practices: 2013.

Authors:  Emanuel Kanal; A James Barkovich; Charlotte Bell; James P Borgstede; William G Bradley; Jerry W Froelich; J Rod Gimbel; John W Gosbee; Ellisa Kuhni-Kaminski; Paul A Larson; James W Lester; John Nyenhuis; Daniel Joe Schaefer; Elizabeth A Sebek; Jeffrey Weinreb; Bruce L Wilkoff; Terry O Woods; Leonard Lucey; Dina Hernandez
Journal:  J Magn Reson Imaging       Date:  2013-01-23       Impact factor: 4.813

5.  Quantitative assessment of artifacts on cardiac magnetic resonance imaging of patients with pacemakers and implantable cardioverter-defibrillators.

Authors:  Takeshi Sasaki; Rozann Hansford; Menekhem M Zviman; Aravindan Kolandaivelu; David A Bluemke; Ronald D Berger; Hugh Calkins; Henry R Halperin; Saman Nazarian
Journal:  Circ Cardiovasc Imaging       Date:  2011-09-23       Impact factor: 7.792

Review 6.  Current clinical issues for MRI scanning of pacemaker and defibrillator patients.

Authors:  Ron Kalin; Marshall S Stanton
Journal:  Pacing Clin Electrophysiol       Date:  2005-04       Impact factor: 1.976

7.  Modified wideband three-dimensional late gadolinium enhancement MRI for patients with implantable cardiac devices.

Authors:  Shams Rashid; Stanislas Rapacchi; Kalyanam Shivkumar; Adam Plotnik; J Paul Finn; Peng Hu
Journal:  Magn Reson Med       Date:  2015-03-13       Impact factor: 4.668

8.  Cardiovascular magnetic resonance in cardiac sarcoidosis with MR conditional pacemaker in situ.

Authors:  Giovanni Quarta; Diana R Holdright; Gordon T Plant; Allan Harkness; Derek Hausenloy; Harpreet Hyare; James C Moon
Journal:  J Cardiovasc Magn Reson       Date:  2011-05-03       Impact factor: 5.364

Review 9.  Clinical utility of cardiovascular magnetic resonance in hypertrophic cardiomyopathy.

Authors:  Martin S Maron
Journal:  J Cardiovasc Magn Reson       Date:  2012-02-01       Impact factor: 5.364

10.  Association of fibrosis with mortality and sudden cardiac death in patients with nonischemic dilated cardiomyopathy.

Authors:  Ankur Gulati; Andrew Jabbour; Tevfik F Ismail; Kaushik Guha; Jahanzaib Khwaja; Sadaf Raza; Kishen Morarji; Tristan D H Brown; Nizar A Ismail; Marc R Dweck; Elisa Di Pietro; Michael Roughton; Ricardo Wage; Yousef Daryani; Rory O'Hanlon; Mary N Sheppard; Francisco Alpendurada; Alexander R Lyon; Stuart A Cook; Martin R Cowie; Ravi G Assomull; Dudley J Pennell; Sanjay K Prasad
Journal:  JAMA       Date:  2013-03-06       Impact factor: 56.272

View more
  7 in total

1.  An eight-year prospective controlled study about the safety and diagnostic value of cardiac and non-cardiac 1.5-T MRI in patients with a conventional pacemaker or a conventional implantable cardioverter defibrillator.

Authors:  Pierpaolo Lupo; Riccardo Cappato; Giovanni Di Leo; Francesco Secchi; Giacomo D E Papini; Sara Foresti; Hussam Ali; Guido M G De Ambroggi; Antonio Sorgente; Gianluca Epicoco; Paola M Cannaò; Francesco Sardanelli
Journal:  Eur Radiol       Date:  2018-01-09       Impact factor: 5.315

Review 2.  Cardiovascular magnetic resonance in patients with magnetic resonance conditional pacemaker systems at 1.5 T: influence of pacemaker related artifacts on image quality including first pass perfusion, aortic and mitral valve assessment, flow measurement, short tau inversion recovery and T1-weighted imaging.

Authors:  Oliver Klein-Wiele; Marietta Garmer; Martin Busch; Serban Mateiescu; Rhyan Urbien; Gianluca Barbone; Kaffer Kara; Michael Schulte-Hermes; Frauke Metz; Birgit Hailer; Dietrich Grönemeyer
Journal:  Int J Cardiovasc Imaging       Date:  2016-11-04       Impact factor: 2.357

3.  Reducing cardiac implantable electronic device-induced artefacts in cardiac magnetic resonance imaging.

Authors:  Aino-Maija Vuorinen; Lauri Lehmonen; Jarkko Karvonen; Miia Holmström; Sari Kivistö; Touko Kaasalainen
Journal:  Eur Radiol       Date:  2022-08-27       Impact factor: 7.034

Review 4.  Intra-cardiac distribution of late gadolinium enhancement in cardiac sarcoidosis and dilated cardiomyopathy.

Authors:  Makoto Sano; Hiroshi Satoh; Kenichiro Suwa; Masao Saotome; Tsuyoshi Urushida; Hideki Katoh; Hideharu Hayashi; Takeji Saitoh
Journal:  World J Cardiol       Date:  2016-09-26

5.  Clinical utility of cardiovascular magnetic resonance imaging in patients with implantable cardioverter defibrillators presenting with electrical instability or worsening heart failure symptoms.

Authors:  Frank Lindemann; Sabrina Oebel; Ingo Paetsch; Arash Arya; Nikolaos Dagres; Sergio Richter; Borislav Dinov; Sebastian Hilbert; Susanne Loebe; Clara Stegmann; Michael Doering; Andreas Bollmann; Gerhard Hindricks; Cosima Jahnke
Journal:  J Cardiovasc Magn Reson       Date:  2020-05-11       Impact factor: 5.364

6.  Feasibility and validation of trans-valvular flow derived by four-dimensional flow cardiovascular magnetic resonance imaging in pacemaker recipients.

Authors:  Christopher E D Saunderson; Maria F Paton; Amrit Chowdhary; Louise A E Brown; John Gierula; Anshuman Sengupta; Christopher Kelly; Pei G Chew; Arka Das; Thomas P Craven; Rob J van der Geest; David M Higgins; Liang Zhong; Klaus K Witte; John P Greenwood; Sven Plein; Pankaj Garg; Peter P Swoboda
Journal:  Magn Reson Imaging       Date:  2020-09-02       Impact factor: 2.546

7.  Evidence to support magnetic resonance conditional labelling of all pacemaker and defibrillator leads in patients with cardiac implantable electronic devices.

Authors:  Anish N Bhuva; Russell Moralee; Tamara Brunker; Karen Lascelles; Lizette Cash; Kush P Patel; Martin Lowe; Neha Sekhri; Francisco Alpendurada; Dudley J Pennell; Richard Schilling; Pier D Lambiase; Anthony Chow; James C Moon; Harold Litt; A John Baksi; Charlotte H Manisty
Journal:  Eur Heart J       Date:  2022-07-07       Impact factor: 35.855

  7 in total