Yuqing Liu1, Bo Weng2, Joselito M Razal3, Qun Xu4, Chen Zhao1, Yuyang Hou1, Shayan Seyedin3, Rouhollah Jalili1, Gordon G Wallace1, Jun Chen1. 1. ARC Centre of Excellence for Electromaterials Science, Intelligent Polymer Research Institute, Australian Institute of Innovative Materials, Innovation Campus, University of Wollongong, Wollongong, NSW 2522, Australia. 2. Chongqing Key Lab for Advanced Materials &Clean Energies of Technologies, Institute for Clean Energy and Advanced Materials, Southwest University, Beibei, Chongqing, 400715 China. 3. Deakin University, Institute for Frontier Materials, Geelong, VIC 3220, Australia. 4. College of Materials Science and Engineering, Zhengzhou University, Zhengzhou, 450052 China.
Abstract
Although great attention has been paid to wearable electronic devices in recent years, flexible lightweight batteries or supercapacitors with high performance are still not readily available due to the limitations of the flexible electrode inventory. In this work, highly flexible, bendable and conductive rGO-PEDOT/PSS films were prepared using a simple bar-coating method. The assembled device using rGO-PEDOT/PSS electrode could be bent and rolled up without any decrease in electrochemical performance. A relatively high areal capacitance of 448 mF cm(-2) was achieved at a scan rate of 10 mV s(-1) using the composite electrode with a high mass loading (8.49 mg cm(-2)), indicating the potential to be used in practical applications. To demonstrate this applicability, a roll-up supercapacitor device was constructed, which illustrated the operation of a green LED light for 20 seconds when fully charged.
Although great attention has been paid to wearable electronic devices in recent years, flexible lightweight batteries or supercapacitors with high performance are still not readily available due to the limitations of the flexible electrode inventory. In this work, highly flexible, bendable and conductive rGO-PEDOT/PSS films were prepared using a simple bar-coating method. The assembled device using rGO-PEDOT/PSS electrode could be bent and rolled up without any decrease in electrochemical performance. A relatively high areal capacitance of 448 mF cm(-2) was achieved at a scan rate of 10 mV s(-1) using the composite electrode with a high mass loading (8.49 mg cm(-2)), indicating the potential to be used in practical applications. To demonstrate this applicability, a roll-up supercapacitor device was constructed, which illustrated the operation of a green LED light for 20 seconds when fully charged.
The need to develop next-generation wearable and flexible electronics in various fields
has promoted the development of highly flexible energy storage devices with high
performance. Among various energy storage devices, such as batteries1,
fuel cells2 and supercapacitors (SCs)2345, SCs are
the most promising candidates for flexible devices because of their relatively simple
structures, the ease for large scale production, as well as their inherent
electrochemical properties (i.e. high energy and power density, fast
charge-discharge and extremely long cycle life)3.The most crucial factor for fabricating flexible SCs is the development of flexible
electrodes with high capacitance and high electrical conductivity to ensure fast
charge-discharge. A common method to make flexible electrode is by depositing
electroactive materials on soft and flexible substrates with porous structure. For
example, carbon dispersions (carbon nanotubes, graphene oxide etc.) have been
deposited as inks on cellulose papers6, porous cotton7 and
synthetic polymer sponges8. Conducting polymers, such as polypyrrole9, polyaniline10 or
poly(3,4-ethylenedioxythiophene)(PEDOT)11 have been directly
deposited on soft and porous substrates via chemical or electrochemical polymerization.
Despite their high flexibility and good ion accessibility, the electrical conductivity
of these electrodes has been limited by insulating properties of substrates used
affecting the charge-discharge rate of SCs. In addition, the total SC device weight
increased due to the use of insulating substrates, leading to a decrease of capacitance
per unit weight. To resolve this problem, some researchers have prepared free-standing
flexible electrodes using vacuum filtration121314 or spray coating
active materials on flexible PET film151617 to create super-thin
electrode films. SC devices made from these electrodes often exhibit high gravimetric
capacitance. However, the gravimetric capacitance is not maintained when the mass
loading or thickness of the films is increased, making them unsuitable for practical
applications. The capacitance further decreases when solid-state electrolyte is used
because large electrolyte ions could not penetrate into the densely packed electrode
materials14. In addition, the device flexibility suffers when thicker
electrodes are used. Fabrication of highly flexible SC electrode materials with
outstanding performance remains a challenge.Poly(3,4-ethylenedioxythiophene)/poly(styrenesulfonate) (PEDOT/PSS) is considered a
promising material for SC electrodes mainly due to its high conductivity, good chemical
and electrochemical stability, and excellent dispersibility in various solvents181920. Reduced graphene oxide (rGO) is another promising SC electrode
material. It has a high capacitance and an extremely long cycle life due to the
ultrahigh specific surface area and the electric double layer mechanism that is the
basis of the charge-discharge process. However, the capacitance of pure rGO films is
often limited by re-stacking of layers2122232425. Therefore,
additives which can prevent re-stacking and simultaneously enhance electrochemical
performance have been incorporated into rGOs when used as SC electrodes2122232425.In this work, we successfully prepared free-standing, large-area and flexible
rGO-PEDOT/PSS composite membranes via a simple bar-coating method. We demonstrate
that these membranes are highly flexible and can be rolled to fabricate SC devices.
Commercial PEDOT/PSS was selected as the conductive matrix to prevent re-stacking of rGO
layer and at the same time, to impart additional flexibility to the electrodes. The
composite films demonstrated high flexibility and conductivity, and when assembled into
all-solid-state SCs using PVA-H3PO4 gel as electrolyte, the
devices could be bent at any angle without a significant decrease in electrochemical
performance. We demonstrate that the rolled-up SC devices can power a green LED light
for 20 seconds when fully charged.
Results
A large-size
(30 cm × 7 cm)
free-standing PEDOT/PSS-DEG film was prepared by bar-coating a thin layer of
PEDOT/PSS and diethylene glycol (DEG) solution as described in experimental section.
The digital photographs of the free-standing PEDOT/PSS film
(14 μm thickness) shown in Fig. 1a,b
illustrate that it is highly flexible and can be bent and twisted. Ethylene glycol
and DEG are commonly used secondary dopants to improve the conductivity of
PEDOT/PSS18262728293031. A PEDOT/PSS film without DEG
(pristine PEDOT/PSS) was also prepared under the same condition as a control. The
PEDOT/PSS-DEG has a high electrical conductivity
(230 S cm−1), which is nearly
two orders higher than pristine PEDOT/PSS
(3.2 S cm−1). This difference
in conductivity can be explained to be the result of phase separation of the excess
insulating PSS domains from the PEDOT/PSS domains induced by DEG to create a highly
conducting PEDOT/PSS network18.
Figure 1
(a,b) photographs of the as-prepared large size
(30 cm × 7 cm),
free-standing, and highly flexible PEDOT/PSS film. Cross-sectional SEM
images of PEDOT/PSS (c) with DEG (Diethylene glycol) film and
(d) without DEG film. (e) Comparison between the specific
capacitance of PEDOT/PSS electrodes with and without DEG at
50 mV s−1.
A scanning electron microscopy (SEM) study of the cross-sections of the films reveal
more macro-scale porosity in PEDOT/PSS-DEG film (Fig. 1d)
compared to the pristine PEDOT/PSS film (Fig. 1c). It is
assumed that the micro sized pores were previously occupied by DEG when the films
were dried at room temperature. Most of the DEG during this step was removed upon
oven drying and created macro pores.The increase in porosity resulted in a better electrochemical performance in terms of
specific capacitance (Fig. 1e) because the increase in
porosity has increased the accessible surface area. Furthermore, the PEDOT/PSS-DEG
film can retain a highly rectangular CV curve when the scan rate was increased to
200 mV s−1 (Supplementary Fig. S1), indicative of high charge
mobility. The small semi-circle in the high frequency domain of the electrochemical
impedance spectra (EIS) also showed low polarisation resistance, indicating fast
diffusion of electrolyte ions. These results suggest that the treatment with DEG
enhanced the electrical conductivity and porosity of the PEDOT/PSS film
significantly as was reflected in the higher specific capacitance. This treatment
method was therefore utilized in the preparation of rGO-PEDOT/PSS films and all the
samples in the following statement without specific illustration were treated with
DEG.Figure 2 shows the cross-sectional SEM images of rGO, PEDOT/PSS
and rGO-PEDOT/PSS composite films. The pristine rGO film (Fig.
2a and Supplementary Fig.
S2a) has a layered structure with closed edges, which is formed by re-stacking
and interlocking of individual sheets. Such a densely stacked structure has
previously been shown to hinder the electrolyte ion diffusion, resulting in an
insufficient utilization of rGO’s potential capacitance13212232. When PEDOT/PSS and DEG were incorporated into this
system (i.e. forming the rGO-PEDOT/PSS film), the cross-section of the film
displayed an open edge that could be seen under SEM (Fig.
2c,e, and Supplementary Fig.
S2b). This open edge indicates that the presence of PEDOT/PSS and DEG have
effectively prevented the re-stacking of individual graphene sheets and provided a
higher accessible surface area. In addition, the hydrophilic property of PEDOT/PSS
can also help electrolyte ions to penetrate into and access the inner surface of the
electrode materials. Images of the composite film without DEG were shown in Fig. 2d,f for comparison. It was found that there is still some
re-stacking of several layers of rGO sheets that are separated by PEDOT/PSS. The
space between two single layers appears smaller than samples with DEG although it is
much larger than pure rGO, showing the addition of DEG in the composite films can
also increase the porosity and surface area as in PEDOT/PSS film.
Figure 2
SEM cross-section images of the various films.
(a) rGO, (b) PEDOT/PSS, (c) and rGO-PEDOT/PSS with DEG,
(d) rGO-PEDOT/PSS without DEG, (e) rGO-PEDOT/PSS with DEG
(higher magnification) and (f) rGO-PEDOT/PSS without DEG (higher
magnification).
Both pristine and composite materials were also investigated using X-ray diffraction
(XRD) measurements. The XRD patterns of PEDOT/PSS, GO, rGO, GO-PEDOT/PSS and
rGO-PEDOT/PSS are shown in Fig. 3a. PEDOT/PSS exhibited a peak
at 2θ = 25.9°, which is related to
the (020) plane of the PEDOT/PSSpolymer backbone33. This peak is
also observed in the XRD spectra of GO-PEDOT/PSS and rGO-PEDOT/PSS. For GO and
GO-PEDOT/PSS, the distinct peaks were found at
2θ = 8.8° and 7.6°,
respectively. These peaks are correlated to the (002) diffraction of GO sheet, from
which the interlayer d spacing values have been calculated to be
0.94 nm and 1.16 nm according to Bragg’s law
(equation (1), where n = 1,
λ is the wavelength of incident wave
(1.54 Å))34, respectively. This slight
increase of interlayer spacing in GO-PEDOT/PSS composite film could be attributed to
the good interaction of PEDOT/PSS with individual GO sheets and their intercalation
in between GO layers35. After reduction by hypophosphorous acid
(HPA)36, the specific GO peaks at around 10°
disappeared in both rGO and rGO-PEDOT/PSS samples and broad peaks were observed at
around 2θ = 24.1° for rGO and
2θ = 18.5° for the composite film.
These peaks corresponded to interlayer distance that decreased to
0.37 nm and 0.48 nm, respectively. In addition,
rGO-PEDOT/PSS composite sample without DEG treatment was also characterized by XRD,
with a interlayer distance (0.46 nm) slightly smaller than sample with
DEG treatment, further indicating DEG’s role in increasing porosity and
surface area.
Figure 3
Properties of the rGO, GO, PEDOT/PSS, GO-PEDOT/PSS and rGO-PEDOT/PSS films
characterized by (a) XRD, (b) Raman, (c) TGA and (d) FT-IR.
The Raman spectra of samples discussed above are shown in Fig.
3b. The signature peaks for PEDOT/PSS (580, 994, 1263, 1372, 1432 and
1535 cm−1) were also found in
rGO-PEDOT/PSS composite albeit with significantly weaker intensity33.
Three main peaks of rGO at 1330, 1590 and
2628 cm−1 associated with the D, G and 2D
bands, respectively, can also be observed in the composite films. The D/G intensity
ratio of the composite films increased from 1.12 (GO-PEDOT/PSS) to 1.25
(rGO-PEDOT/PSS) after HPA treatment suggesting reduction of defects in GO37. In addition, the increased 2D intensity because of the recovery of
crystallinity also verified the reduction of GO38.The Fourier transform infrared spectra (FTIR) (Fig. 3d)
corroborated the Raman results. All of the PEDOT/PSS signature peaks (S-O and
S-phenyl bonds in sulfonic acid located at 1167, 1126 and
1029 cm−1, respectively; and
C = C, C-C and C-S bonds in the thiophene backbone at 1580,
1508, 1001, 894, 771 and 706 cm−1,
respectively) were observed in the rGO-PEDOT/PSS composite films at lower
intensity33. From the comparison of GO-PEDOT/PSS and
rGO-PEDOT/PSS (shown as inset), the peaks for GO at
1045 cm−1 and
1209 cm−1 (epoxy C-O stretching
vibration) and 1650 cm−1 (associated with
carboxyl group) can be seen in GO-PEDOT/PSS but not in rGO-PEDOT/PSS, indicating the
reduction of GO in the composite films.The thermal stability of rGO-PEDOT/PSS composites in air was examined by
Thermo-gravimetric analysis (TGA). Figure 3c shows the
comparison of weight loss of pristine rGO, pristine PEDOT/PSS and rGO-PEDOT/PSS
composite. The rGO-PEDOT/PSS composite films show little weight loss below
250 °C indicating a wide operating temperature range, which
is important for many applications. Above 250 °C, there was
a significant mass loss, which is attributed to the rupture of the sulfonate group
from PSS34. The steepest weight loss was observed at
500 °C, which is attributed to both the degradation of the
polymer backbone and the oxidation of rGO34.The reduction of GO in the composites is also evident in the enhancement of
electrical conductivity and electrochemical performance of the samples containing
various rGO loading. Supplementary Fig.
S3 shows the electrical conductivity of all films before and after
reduction. All films containing GO shows a remarkable increase in conductivity after
reduction. Among all composite films, the rGO-PEDOT/PSS film with
33 wt.% GO loading displayed the highest conductivity of
92.5 S cm−1. In addition, the
rGO-PEDOT/PSS film also had the most rectangular shaped CV among the samples
investigated, indicating the enhanced double layer capacitance.The rGO-PEDOT/PSS composite films with various GO loadings were prepared and
assembled in an all-solid-state supercapacitor (SC) device, as illustrated in Fig. 4. The pristine PEDOT/PSS and pristine rGO films were also
prepared using the same method for comparison. The composite films displayed high
flexibility and the assembled device could be bent and twisted without impairing the
integrity of the device (Fig. 4). Solid-state supercapacitors
were fabricated by sandwiching poly(vinyl alcohol) (PVA)/H3PO4
solid-state electrolyte between two symmetric electrode films. The active area of
all fabricated solid-state supercapacitors was set at
2 cm × 0.8 cm. The
various mass loadings and thicknesses of the electrode films are presented in Supplementary Table S1. Evaluation of all
composite devices revealed that the best electrochemical performance (in terms of
capacitance and charge transfer rate) was obtained from the device containing
33 wt.% GO loading (Supplementary
Fig. S8), and was therefore selected for further study.
Figure 4
Schematic illustration of the preparation process of rGO-PEDOT/PSS films and
the structure of assembled supercapacitor devices.
The optimal rGO-PEDOT/PSS device (33 wt.% GO) presented superior
performance than neat PEDOT/PSS and neat rGO device in terms of capacitance, charge
transfer rate, energy and power densities (Fig.
5a–c). The CV curve of this device exhibited a more
rectangular shape and larger area than that of the PEDOT/PSS and rGO devices (Fig. 5a), indicating a faster charge transfer rate and a higher
capacitance than other samples. Figure 5b shows that the
composite device exhibits specific capacitance larger than either of the pure
PEDOT/PSS or rGO at all scan rates of
5–500 mV s−1. In
addition, the decrease in specific capacitance and shape distortion from
rectangularity of CV curve of composite film are much lower than pure rGO device
when changing from aqueous electrolyte to solid electrolyte (Supplementary Fig. S6). This illustrates that the
larger interlayer spacing in the composite films enables the larger ions in the
solid electrolyte to penetrate into the interlayer space and access the inner layer
surface. Comparison of CV curves and specific capacitance of the composite device
with and without DEG (Supplementary Fig.
S7) showed enhancement of both capacitance and rate capability of the
composite film by the addition of DEG. Figure 5d shows CV
curves of rGO-PEDOT/PSS optimal device at different scan rates from
5 mV s−1 to
200 mV s−1. All CV curves
retain their highly rectangular shape, indicating the device’s fast
charge transfer rate and good conductivity.
Figure 5
Electrochemical performance of pristine rGO, pristine PEDOT/PSS, and
rGO-PEDOT/PSS (33 wt.% GO) SC device.
(a) CVs of pure rGO, PEDOT/PSS, and rGO-PEDOT/PSS devices at a scan
rate of 50 mV s−1.
(b) Specific capacitance of rGO, PEDOT/PSS, and rGO-PEDOT/PSS
electrodes calculated from CV. (c) Ragone Plot of all the above
electrodes. (d) CV curves of rGO-PEDOT/PSS at different scan rates
(with inset capacitance vs current density). (e) Galvanostatic
charge/discharge curves of rGO-PEDOT/PSS at different current densities.
(f) Capacitance and Coulombic efficiency of rGO-PEDOT/PSS device
during the 20,000 cycles.
There is also a remarkable improvement in the power and energy densities (based on
two electrode weight, calculated from CV data; Supplementary Equation S7 and S8), which can be observed from the Ragone
plot in Fig. 5c. The device containing optimal rGO-PEDOT/PSS
electrode can achieve a maximum power and energy densities
(3,589.5 W kg−1 and
2.83 Wh kg−1, respectively),
which are significantly higher than devices made of pure rGO electrode
(159.8 W kg−1 and
1.95 Wh kg−1, respectively)
and pure PEDOT/PSS electrode
(1,967.5 W kg−1 and
1.00 Wh kg−1, respectively).
The symmetry of the galvanostatic charge/discharge curves Fig.
5e of the rGO-PEDOT/PSS signifies the excellent capacitive
characteristic, with the discharge time decreasing with increasing the applied
current, leading to a slight decrease in specific capacitance (inset in Fig. 5e). No significant iR drop is observed at the beginning of
the constant current discharge, indicative of the low contact resistance in the
device. The long-term charge-discharge performance of this device was also evaluated
(Fig. 5f). After 10,000 cycles of constant current
charge/discharge at 1 A g−1, the
capacitance retention was more than 95%. When tested for another 10,000
charge/discharge cycles at a higher current density of
2 A g−1, the capacitance
remained above 85% of the initial value, suggesting that the device has high
stability, long cycle life, and high rate capability. The Coulombic efficiency is
also close to 100% for all cycles indicating the high stability of the device (Fig. 5f). This high stability is also shown in the Nyquist plots
(Supplementary Fig. S9). A slight
decrease in semi-circle of the high frequency region after 10,000 and 20,000
charge/discharge cycles demonstrates decreased polarisation resistance
(Rct). In addition, the intercept of the real part of impedance with
the x-axis (Rs, representative of the resistance of the
electrolyte and the contact resistance) also decreased slightly. These results
suggest that the inner surface of electrode materials has been fully wetted by the
electrolyte after 10,000 cycles with only a minimal mechanical failure from the
polymer doping/dedoping and ion absorbing/desorbing process3940.Cyclic voltammetry (CV) (Fig. 6a) and the charge/discharge
curves in Supplementary Fig. S9 confirm
that no significant change was observed during bending at various angles. Bending up
to 1,000 times at 180° did not change the shape of the CV responses
(Fig. 6b). The long term galvanostatic tests illustrated
that the capacitance tested under 180° after 10,000 cycles only
decreased by 11.6% compared with 0°, indicating excellent device
performance under large bending angles. In addition, the SC device made from a long
strip of electrodes
(15 cm × 2 cm) that have
been rolled-up as shown in Fig. 6d,e was powerful enough to
power a light-emitting diode for 20 seconds when fully charged (Fig. 6f).
Figure 6
(a) CVs of rGO-PEDOT/PSS during bending. Scan
rate = 50 mV s−1.
(b) CVs of rGO-PEDOT/PSS after being subject to bending.
(c) Long-term test of rGO-PEDOT/PSS under flat or 180 degree
bended states at a current density of
1 A g−1. (d)
Flexible films coated with solid electrolyte spread out on an Au-coated
membrane, (e) rolled design and (f) the resulting device used
to power a green light-emitting diode (LED).
Discussion
We attribute the improved performance (e.g. higher capacitance, better rate
capability and energy/power density) of rGO-PEDOT/PSS composite film than pure rGO
to the increased porous structure and electrical conductivity. We have now provided
higher resolution SEM images that compare the cross-sections of rGO and
rGO-PEDOT/PSS films in Supplementary Fig.
S2. The pure rGO film shows a densely stacked layer structure while the
composite film shows an open edge and more porous structure. In addition, XRD
results also showed the supporting evidence that the interlayer distance of rGO has
been increased from 0.37 nm (for pure rGO film) to 0.48 nm
(for rGO-PEDOT/PSS), confirming the effective intercalation of PEDOT/PSS in between
rGO layers (Fig. 3a). These results indicated that the
restacking problem of rGO sheets has been effectively prevented in the composite
film, resulting in a better utilization of rGO’s high capacitance
(189 F g−1 for rGO only in
composite film than 56.11 F g−1
for pure rGO film, supplementary Table
S2). Furthermore, the improved conductivity of the composite film
(92.5 S cm−1) that is over 7
times higher than that of pure rGO film
(12.1 S cm−1) can explain its
more rectangular CV shape and faster charge transfer at high charge-discharge
rates.Notably, the gravimetric capacitance of the optimized rGO-PEDOT/PSS film in this work
is only 81 F g−1 at the lowest
scan rate of 5 mV s−1, which is
much lower than many literature values of graphene-PEDOT based SCs
(100 ~ 300 F g−1)4142. That is due to the limited gravimetric capacitance
(28.9 F g−1 even after
optimized by DEG) of commercialized PEDOT/PSS utilised in this work. To achieve the
aim of industrial large scale fabrication of rGO-PEDOT/PSS large area SCs,
commercialised PEDOT/PSS was chosen instead of specially designed high performance
PEDOT/PSS4 to work as flexible and conductive platform matrix for
rGO sheets, which lead to the weaker performance in comparison with previous work.
However, the specifically high conductivity of PEDOT-PSS utilised in this work
enable the fast charge transfer in the SCs, promising the high mass loading of
electrode materials which resulted high areal capacitance.It has been reported that thin electrode films often lead to better specific
capacitance performance because electrons and electrolyte ions can be easily
transferred1443. However, in most practical applications, high
mass loading and hence film thickness is necessary to increase device capacity.
Here, devices with various electrode material mass loading were fabricated to
investigate the relationship between mass loading and specific (i.e. areal,
volumetric and gravimetric) capacitance of the PEDOT/PSS-rGO composite electrode
with 33 wt.% GO loading. As shown in Fig. 7a, the
areal capacitance increases with mass loading initially before reaching the highest
value of 448 mF cm−2 at
8.49 mg cm−2 at a scan rate
of 10 mV s−1. This performance is
comparable with previously reported values for graphene (Laser scribing graphene
(LSG)44, Graphene-Cellulose nanofiber (G-CNF) aerogel23, and Graphene-cellulose paper45), CNT1446 and conducting polymer10 solid-state SCs as
listed in Supplementary Table S3. The
gravimetric capacitance at this loading is
52.7 F g−1. Also, the
volumetric capacitance
(49.9 F cm−3) is higher than
reported values for solid state graphene
(9.6 F cm−3)44, graphene hydrogel
(31 F cm−3)43
and PEDOT paper (35 F cm−3)47. In addition, the volumetric capacitance
(3.4 F cm−3) of the whole SC
device (i.e. taking into account the mass of the 0.66 mm thick
electrode, electrolyte and package membranes) is significantly higher than previous
reports CNT (0.30 F cm−3)46, and graphene
(0.42 F cm−3)12, and comparable with PEDOT-paper
(5 F cm−3)47.
The areal capacitances vs. mass loading at different scan rates were shown in
Supplementary Fig. S10. At a high
scan rate of 100 mV s−1, the
device with 8.49 mg cm−2 mass
loading can retain an areal capacitance of
300 mF cm−2, indicating good
rate capability. The symmetric galvanostatic charge/discharge curves (Supplementary Fig. S10) under different current
densities signified good capacitive characteristic. The device delivers an energy
density of
34 μWh cm−2,
which is higher than G-CNF aerogel SC
(20 μWh cm−2)23, Graphene hydrogel SC
(25.8 μWh cm−2)43, Graphene cellulose paper SC
(2 μWh cm−2)45 and PEDOT paper SC
(17 μWh cm−2)47. It was also found that the flexibility of the device was not
affected by the increase of electrode film thickness. As shown in Fig. S8c and d, the CV responses obtained for
these devices have negligible difference when bent at different angles and for 1,000
times at 180°.
Figure 7
(a) Gravimetric, areal and volumetric capacitance vs. mass
loading at a scan rate of
10 mV s−1, (b)
Ragone plot of rGO-PEDOT/PSS device with a high mass loading of
8.49 mg cm−2.
In summary, highly flexible free-standing rGO-PEDOT/PSS films have been successfully
prepared and fabricated into flexible all-solid-state SC devices using
PVA/H3PO4 as an electrolyte. The incorporation of
PEDOT/PSS and DEG into GO sheets increased the interlayer spacing of GO sheets and
prevented the GO sheets from re-stacking, which significantly improved the
electrochemical performance of the assembled SCs, created more effective surface
area and improved the penetration of large sized solid electrolyte ions into the
electrode materials. The GO in composite films can be reduced effectively using HPA
as the reducing agent, which was verified by FTIR, Raman and XRD and electrical
conductivity measurements. The maximum areal capacitance
(448 mF cm−2) was obtained
using 33% rGO-PEDOT/PSS electrode film with
8.49 mg cm−2 loading at a
scan rate of 10 mV s−1. Notably,
this composite material performed better than previous reports and showed little
changes in capacitance when bent at various angle for 1,000 times. This excellent
performance and the ease of fabrication suggest that such electrode materials are
good candidates for bendable SC devices that are practical for large scale use.
Methods
Materials
Graphite flakes, diethylene glycol (DEG), hydrogen peroxide
(H2O2), poly (vinyl alcohol) (PVA, Mw:
146000 ~ 186000) and hypophosphorous acid
(HPA) were purchased from Sigma-Aldrich. Concentrated sulphuric acid
(H2SO4, 98%), orthophosphoric acid
(H3PO4, 85%), and hydrochloric acid (HCl, 32%) were
obtained from Chem-Supply.
Poly(3,4-ethylenedioxythiophene)/poly(styrenesulfonate) (PEDOT/PSS) pellets was
Orgacon™ DRY re-dispersible product from Agfa company.
Preparation of large PEDOT/PSS flexible films
PEDOT/PSS pellets were dispersed in deionized water at a concentration of
20 mg mL−1 by magnetic
stirring and then diethylene glycol (DEG) was added to the dispersion at
37.2 mg mL−1. The
dispersion was stirred overnight and then sonicated (Branson B5500R-DTH bath
sonicator, low power) for 30 minutes prior to use. The mixture was
bar-coated on a hydrophilic PVDF membrane substrate with glass slides (use side
face) encircled to fix films’ shape and size. The thickness of the
film was controlled by the volume of dispersion used per unit area of the film.
The film was first dried overnight at room temperature and then heated in a
60 °C oven (air atmosphere) overnight to evaporate the
remaining water and DEG. A flexible PEDOT/PSS film was then peeled off from the
PVDF membrane.
Preparation of graphene oxide
Graphene Oxide (GO) dispersion was prepared using the modified Hummers
method48. Firstly, a mixture of concentrated
H2SO4/H3PO4
(360:40 mL) was added to a mixture of graphite flakes
(3.0 g, 1 wt. equiv.) and KMnO4
(18.0 g, 6 wt. equiv.). The reaction was
heated to 50 °C and stirred for 14.5 hrs,
cooled to room temperature, and poured onto ice
(~400 mL) with 30% H2O2
(20 mL). The mixture was then stirred for 30 min and
centrifuged at 4,400 rpm for 20 min. The precipitate was
washed and centrifuged with HCl solution (9:1 water/HCl by volume) twice and
then dispersed in water and dialyzed for 7 days. The graphene oxide dispersion
was finally obtained by probe sonicating (Branson Digital sonifier,
400 watt, 38% amplitude) the purified graphite oxide dispersion for
1 hr, with a pulse of two seconds on and one second off, totally
1.5 hrs.
Preparation of rGO-PEDOT/PSS flexible films
The composite dispersions were prepared by the addition of PEDOT/PSS into the GO
dispersions. Samples with various GO loadings of 20 wt.%,
33 wt.%, 50 wt.%, 67 wt.% and
80 wt.% were prepared. In each sample, the total concentration
(solid content) of PEDOT/PSS and GO was kept at
20 mg mL−1. Diethylene
glycol was added to each sample at
33.2 mg/mL−1. GO-PEDOT/PSS films were
prepared the same way as PEDOT/PSS films. All films were immersed in
5 wt.% HPA and then heated to 60 °C for
24 hours, rinsed with water and dried at room temperature.
Electrochemical characterization
Films were assembled into two electrode all-solid-state symmetric supercapacitor
devices by the following methods. A H3PO4/PVA gel
electrolyte was prepared by mixing PVA powder (4 g),
H3PO4 (6 g) and deionized water
(40 mL) together. The mixture was heated to around
85 °C under magnetic stirring until the solution became
clear. 150 nm gold was sputter coated directly on one side of
electrode film which served as current collector. Hot
PVA/H3PO4 electrolyte (heated to
85 °C prior to use) was drop cast onto the other side of
the electrode films. Films were left in air overnight to evaporate most of the
water contained in electrolyte. Two films were then pressed together (with both
of the electrolyte side pressed face-to-face) to form an all-solid-state
flexible symmetric supercapacitors.Cyclic voltammetry (CV) test of the assembled devices were performed using a
CHI720 electrochemical work station. Galvanostatic cycling tests were carried
out with a Neware Galvanostat (100 mA, 5 V) equipped
with Test Control V.5.0 software. All calculations of capacitances, energy and
power densities are according to Supplementary Equation S2-S8. The potential window studied was
between 0.01 V to 1 V. Electrochemical impedance
spectroscopy (EIS) were obtained using Solartron SI1260 Impedance Analyser and
EG&G Instruments Princeton Applied Research Potentiostat/Galvanostat
Model 283, and employing a frequency range of 100 kHz to
0.01 Hz and an AC amplitude of 10 mV at open circuit
potential.
Physical characterization
Scanning electron microscopy (SEM) images were obtained from a JEOL JSM-7500FA
field emission SEM in which the accelerating voltage was set at
5.0 kV and the emission current was 10 mA. X-ray
diffraction (XRD) was performed on a GBC MMA XRD
(λ = 1.54 Å) with
the voltage and current kept at −40 kV and
25 mA, respectively. Thermo-gravimetric analysis (TGA) was carried
out in air using Q500 (TA Instruments) with data analysis carried out using the
Q Series software V. 2.5.0.255. The temperature range studied is between
50 °C to 800 °C at rate of
5 °C/min. Fourier transform infrared spectroscopy
(FT-IR) was performed using the Shimadzu AIM8000 FT-IR spectrometer. Raman
spectroscopy was carried out on a Jobin-Yvon Horbia 800 using a
632.81 nm laser. The data analysis was carried out using Labspec
V.5.45.09 software.
Additional Information
How to cite this article: Liu, Y. et al. High-Performance Flexible
All-Solid-State Supercapacitor from Large Free-Standing Graphene-PEDOT/PSS Films.
Sci. Rep.
5, 17045; doi: 10.1038/srep17045 (2015).
Authors: Liangbing Hu; Mauro Pasta; Fabio La Mantia; Lifeng Cui; Sangmoo Jeong; Heather Dawn Deshazer; Jang Wook Choi; Seung Min Han; Yi Cui Journal: Nano Lett Date: 2010-02-10 Impact factor: 11.189
Authors: Daniela C Marcano; Dmitry V Kosynkin; Jacob M Berlin; Alexander Sinitskii; Zhengzong Sun; Alexander Slesarev; Lawrence B Alemany; Wei Lu; James M Tour Journal: ACS Nano Date: 2010-08-24 Impact factor: 15.881