In Vitro Cholesterol Deposition on Daily Disposable Contact Lens Materials.

Hendrik Walther1, Lakshman Subbaraman, Lyndon W Jones.   

Abstract

PURPOSE: The goal of this study was to analyze how various incubation times affect the uptake of cholesterol on silicone hydrogel (SH) and conventional hydrogel (CH) daily disposable (DD) contact lens materials using an in vitro radiochemical detection method.
METHODS: Three SH (somofilcon A, delefilcon A, and narafilcon A) and four CH (etafilcon A, nesofilcon A, ocufilcon A, and nelfilcon A) contact lenses were incubated in an artificial tear solution that contained major tear film components and a portion of radioactive C-cholesterol. Lenses (N = 4) were incubated for four incubation times (2, 6, 12, or 16 h) to assess the effects on cholesterol deposition. Subsequent to the incubation, the lenses were extracted using 2:1 chloroform:methanol, and the extracts were analyzed in a beta counter and (in nanograms per lens) extrapolated from standard curves.
RESULTS: In general, cholesterol deposited statistically significantly more on SH lenses than CHs (p ≤ 0.033), with the exception of somofilcon A and nesolfilcon A materials (p = 0.067). Within the SH materials, narafilcon A accumulated the largest quantity of cholesterol (p < 0.05) and somofilcon A the lowest (p < 0.05). The uptake of cholesterol ranged from 22.63 ± 2.98 ng/lens to 97.94 ± 4.18 ng/lens for all lens materials. The accumulation of cholesterol was shown to be continuous throughout the 16 h of incubation, without reaching a plateau (p < 0.001).
CONCLUSIONS: For the periods that DD lens materials are worn, cholesterol deposits significantly more onto SH contact lenses than CHs. This could have implications for wearers who have higher levels of lipid in their tears that are fitted with SH DD materials.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26583791     DOI: 10.1097/OPX.0000000000000749

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  5 in total

1.  Development of an Eye Model With a Physiological Blink Mechanism.

Authors:  Chau-Min Phan; Hendri Walther; Ha Qiao; Ra Shinde; Lyndo Jones
Journal:  Transl Vis Sci Technol       Date:  2019-09-03       Impact factor: 3.283

2.  Tear Film Characteristics During Wear of Daily Disposable Contact Lenses.

Authors:  Giancarlo Montani; Maurizio Martino
Journal:  Clin Ophthalmol       Date:  2020-06-04

3.  Development of an In Vitro Blink Model for Ophthalmic Drug Delivery.

Authors:  Chau-Minh Phan; Manish Shukla; Hendrik Walther; Miriam Heynen; David Suh; Lyndon Jones
Journal:  Pharmaceutics       Date:  2021-02-25       Impact factor: 6.321

4.  Differential Deposition of Fluorescently Tagged Cholesterol on Commercial Contact Lenses Using a Novel In Vitro Eye Model.

Authors:  Hendrik Walther; Chau-Minh Phan; Lakshman N Subbaraman; Lyndon Jones
Journal:  Transl Vis Sci Technol       Date:  2018-04-05       Impact factor: 3.283

5.  Nanoscale Characteristics of Ocular Lipid Thin Films Using Kelvin Probe Force Microscopy.

Authors:  Elizabeth Drolle; William Ngo; Zoya Leonenko; Lakshman Subbaraman; Lyndon Jones
Journal:  Transl Vis Sci Technol       Date:  2020-06-29       Impact factor: 3.283