Literature DB >> 26582433

Multichannel quartz crystal microbalance array: Fabrication, evaluation, application in biomarker detection.

Wenyan Tao1, Peng Lin2, Yanqing Ai3, Hairui Wang1, Shanming Ke4, Xierong Zeng5.   

Abstract

A multichannel quartz crystal microbalance array (MQCM) with three pairs of gold electrodes was fabricated for detection of two biomarkers: acetone and nitric oxide (NO). The gold electrodes were deposited symmetrically on an AT-cut 10 MHz circular quartz plate using photolithography, sputtering, and lift-off technologies. The effect of gold layer thickness on MQCM performance was investigated and the optimized thickness was 101 nm. The simulation values of the electric parameters C0, Cq, Lq, and Rq in the Butterworth-Van Dike equivalent circuit for the MQCM device were 97 pF, 1.3 pF, 1.05 mH, and 9.8 Ω, respectively. Simulation values were in the theoretical range, which indicated that the fabricated MQCM device had good resonance performance. Two types of nanocomposites, titanium dioxide-multiwalled carbon nanotubes and cobalt (II)phthalocyanine-silica, were synthesized as sensing materials. The sensing mechanism is based on coordination adsorption of target molecules onto the sensing material, resulting in a resonant frequency shift of modified QCM sensor. A linear range from 4.33 to 129.75 ppmv for acetone was obtained and one from 5.75 to 103.45 ppbv for NO.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Acetone; Multichannel quartz crystal microbalance array; Multiwalled carbon nanotube; Nitric oxide

Mesh:

Substances:

Year:  2015        PMID: 26582433     DOI: 10.1016/j.ab.2015.11.001

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  5 in total

Review 1.  Breath Analysis: A Promising Tool for Disease Diagnosis-The Role of Sensors.

Authors:  Maria Kaloumenou; Evangelos Skotadis; Nefeli Lagopati; Efstathios Efstathopoulos; Dimitris Tsoukalas
Journal:  Sensors (Basel)       Date:  2022-02-06       Impact factor: 3.576

Review 2.  Gas sensors based on mass-sensitive transducers. Part 2: Improving the sensors towards practical application.

Authors:  Alexandru Oprea; Udo Weimar
Journal:  Anal Bioanal Chem       Date:  2020-07-31       Impact factor: 4.142

Review 3.  Bulk and Surface Acoustic Wave Sensor Arrays for Multi-Analyte Detection: A Review.

Authors:  Kerstin Länge
Journal:  Sensors (Basel)       Date:  2019-12-06       Impact factor: 3.576

Review 4.  Recent Advances in Phthalocyanine and Porphyrin-Based Materials as Active Layers for Nitric Oxide Chemical Sensors.

Authors:  Darya Klyamer; Roman Shutilov; Tamara Basova
Journal:  Sensors (Basel)       Date:  2022-01-24       Impact factor: 3.576

5.  Design and Validation of a 150 MHz HFFQCM Sensor for Bio-Sensing Applications.

Authors:  Román Fernández; Pablo García; María García; José V García; Yolanda Jiménez; Antonio Arnau
Journal:  Sensors (Basel)       Date:  2017-09-08       Impact factor: 3.576

  5 in total