Literature DB >> 26581241

Brachial Low-Flow-Mediated Constriction is Associated with Delayed Brachial Flow-Mediated Dilation.

Concetta Irace1, Cesare Tripolino, Faustina Barbara Scavelli, Claudio Carallo, Agostino Gnasso.   

Abstract

AIM: Flow-mediated vasodilation (FMD) of the brachial artery measures the ability of the artery to dilate after a forearm ischemia lasting for 5 min. During ischemia, and therefore in conditions of low flow, constriction of the brachial artery (L-FMC) has sometimes been reported. The meaning of L-FMC is still unclear. The aims of our study were to establish the prevalence of subjects with L-FMC, to determine whether the magnitude of L-FMC correlates with magnitude of FMD, and to determine whether L-FMC can be used to predict FMD timing.
METHODS: A total of 179 outpatients were studied, and the brachial artery diameter was measured every minute during the 5 min forearm ischemia. Subjects who had at least one measurement showing a constriction of > 1% during ischemia were defined as constrictors. FMD was evaluated at 50 s, 2 min, and 3 min after cuff release. On the basis of time, the subjects in whom maximal dilation had occurred were divided into Early, Late, or No dilators.
RESULTS: The brachial artery diameter of 70 subjects (39%) constricted during ischemia. Higher the constriction during ischemia, lower was the dilation after ischemia. Constrictors were more likely to have Late (OR 2.6; ICs 95% 1.19-5.81, p=0.02) or No dilation (OR 4.8; ICs 95% 1.90-12-16, p=0.02) compared with no constrictors.
CONCLUSIONS: The present study reveals that almost 40% of the subjects had brachial artery L-FMC and a more pronounced constriction during ischemia correlated with a lower dilation after ischemia. Finally, the prevalence of subjects showing L-FMC was significantly higher among subjects with delayed or no vasodilation, suggesting that L-FMC may be a marker of endothelial dysfunction.

Entities:  

Mesh:

Year:  2015        PMID: 26581241     DOI: 10.5551/jat.32060

Source DB:  PubMed          Journal:  J Atheroscler Thromb        ISSN: 1340-3478            Impact factor:   4.928


  7 in total

1.  Brachial artery vasodilatory response and wall shear rate determined by multigate Doppler in a healthy young cohort.

Authors:  Kunihiko Aizawa; Sara Sbragi; Alessandro Ramalli; Piero Tortoli; Francesco Casanova; Carmela Morizzo; Clare E Thorn; Angela C Shore; Phillip E Gates; Carlo Palombo
Journal:  J Appl Physiol (1985)       Date:  2017-09-21

2.  Brachial Artery "Low-Flow Mediated Constriction" Is Associated with Myocardial Perfusion Defect Severity and Mediated by an Altered Flow Pattern during Occlusion.

Authors:  Smriti Badhwar; Dinu S Chandran; Ashok K Jaryal; Rajiv Narang; Chetan Patel; Kishore Kumar Deepak
Journal:  Pulse (Basel)       Date:  2021-11-18

3.  Evidence for congruent impairment in micro and macrovascular function in type 1 diabetes.

Authors:  Concetta Irace; Valentina Messiniti; Bruno Tassone; Claudio Cortese; Eugene J Barrett; Agostino Gnasso
Journal:  PLoS One       Date:  2017-11-13       Impact factor: 3.240

4.  Relationship between Flow-mediated Endothelial Vasodilation and the Pulse Wave Velocity, and Cervical Carotid Artery Stenosis.

Authors:  Kazutaka Shirokane; Tomonori Tamaki; Kyongsong Kim; Masato Tsuchiya; Michio Yamazaki; Akio Morita
Journal:  Neurol Med Chir (Tokyo)       Date:  2020-05-14       Impact factor: 1.742

5.  Effect of empagliflozin on brachial artery shear stress and endothelial function in subjects with type 2 diabetes: Results from an exploratory study.

Authors:  Concetta Irace; Antonio Cutruzzolà; Martina Parise; Raffaella Fiorentino; Marco Frazzetto; Chiara Gnasso; Francesco Casciaro; Agostino Gnasso
Journal:  Diab Vasc Dis Res       Date:  2019-11-14       Impact factor: 3.291

6.  Reactivity to low-flow as a potential determinant for brachial artery flow-mediated vasodilatation.

Authors:  Kunihiko Aizawa; Salim Elyas; Damilola D Adingupu; Francesco Casanova; Kim M Gooding; W David Strain; Angela C Shore; Phillip E Gates
Journal:  Physiol Rep       Date:  2016-06

Review 7.  Flow Mediated Dilatation as a Biomarker in Vascular Surgery Research.

Authors:  Kirthi Bellamkonda; Matthew Williams; Ashok Handa; Regent Lee
Journal:  J Atheroscler Thromb       Date:  2017-07-01       Impact factor: 4.928

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.