Literature DB >> 26574711

Inter-Changeability of Impedance Devices for Lymphedema Assessment.

Malou van Zanten1, Neil Piller1, Leigh C Ward2.   

Abstract

Impedance technology is a popular technique for the early detection of lymphedema. The preferred approach is to use bioimpedance spectroscopy (BIS), with measurements being made with the subject lying supine, although attempts have been made to use single or multiple frequency impedance measurements obtained while the subject is standing. The aim of the present study was to determine the equivalence of these different approaches. Impedance measurements of the individual limbs of 37 healthy individuals were determined using both a stand-on, multi-frequency impedance device and a supine impedance spectroscopy instrument. Significant differences were found between the instruments in both absolute impedance values and, importantly, inter-limb impedance ratios. Since impedance ratios in healthy individuals provide the reference standard for detection of lymphedema, these data indicate that the methods are not interchangeable. Consideration of the errors associated with each method indicates that the BIS remains the preferred method for lymphedema detection.

Entities:  

Mesh:

Year:  2015        PMID: 26574711     DOI: 10.1089/lrb.2015.0026

Source DB:  PubMed          Journal:  Lymphat Res Biol        ISSN: 1539-6851            Impact factor:   2.589


  5 in total

1.  Comparison of bioimpedance body composition in young adults in the Russian Children's Study.

Authors:  Sergey Rudnev; Jane S Burns; Paige L Williams; Mary M Lee; Susan A Korrick; Tatiana Denisova; Yuri Dikov; Gennady Kozupitsa; Russ Hauser; Oleg Sergeyev
Journal:  Clin Nutr ESPEN       Date:  2019-11-16

2.  Deep learning-based quantitative estimation of lymphedema-induced fibrosis using three-dimensional computed tomography images.

Authors:  Kyo-In Koo; Chang Ho Hwang; Hyewon Son; Suwon Lee; Kwangsoo Kim
Journal:  Sci Rep       Date:  2022-09-13       Impact factor: 4.996

3.  A Comparison of Supine Versus Stand-on Bioimpedance Devices to Assess Breast Cancer-Related Lymphedema.

Authors:  Judy Mastick; Betty J Smoot; Steven M Paul; Kord M Kober; Deborah Hamolsky; Lori K Madden; Yvette P Conley; Niharika Dixit; Marilyn J Hammer; Mei R Fu; Christine Miaskowski
Journal:  Lymphat Res Biol       Date:  2021-02-09       Impact factor: 2.589

4.  Determination of Bioelectrical Impedance Thresholds for Early Detection of Breast Cancer-related Lymphedema.

Authors:  Siyao Liu; Quanping Zhao; Xinmei Ren; Ying Cui; Houpu Yang; Siyuan Wang; Miao Liu; Shu Wang
Journal:  Int J Med Sci       Date:  2021-06-11       Impact factor: 3.738

5.  Comparison of a novel algorithm quantitatively estimating epifascial fibrosis in three-dimensional computed tomography images to other clinical lymphedema grading methods.

Authors:  Kyo-In Koo; Myoung-Hwan Ko; Yongkwan Lee; Hye Won Son; Suwon Lee; Chang Ho Hwang
Journal:  PLoS One       Date:  2019-12-10       Impact factor: 3.240

  5 in total