Literature DB >> 26571534

Seizure Suppression Efficacy of Closed-Loop Versus Open-Loop Deep Brain Stimulation in a Rodent Model of Epilepsy.

M Tariqus Salam, Jose Luis Perez Velazquez, Roman Genov.   

Abstract

We assess and compare the effects of both closed-loop and open-loop neurostimulation of the rat hippocampus by means of a custom low-power programmable therapeutic neurostimulation device on the suppression of spontaneous seizures in a rodent model of epilepsy. Chronic seizures were induced by intraperitoneal kainic acid injection. Two bipolar electrodes were implanted into the CA1 regions of both hippocampi. The electrodes were connected to the custom-built programmable therapeutic neurostimulation device that can trigger an electrical stimulation either in a periodic manner or upon detection of the intracerebral electroencephalographic (icEEE) seizure onset. This device includes a microchip consisting of a 256-channel icEEG recording system and a 64-channel stimulator, and a programmable seizure detector implemented in a field-programmable gate array (FPGA). The neurostimulator was used to evaluate seizure suppression efficacy in ten epileptic rats for a total of 240 subject-days (5760 subject-hours). For this purpose, all rats were randomly divided into two groups: the no-stimulation group and the stimulation group. The no-stimulation group did not receive stimulation. The stimulation group received, first, closed-loop stimulation and, next, open-loop stimulation. The no-stimulation and stimulation groups had a similar seizure frequency baseline, averaging five seizures per day. Closed-loop stimulation reduced seizure frequency by 90% and open-loop stimulation reduced seizure frequency by 17%, both in the stimulation group as compared to the no-stimulation group.

Entities:  

Mesh:

Year:  2015        PMID: 26571534     DOI: 10.1109/TNSRE.2015.2498973

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  16 in total

1.  On disturbance rejection control of the epileptiform spikes.

Authors:  Wei Wei; Zhiyuan Zhang; Nan Chen; Min Zuo; Tao Yu
Journal:  Cogn Neurodyn       Date:  2021-09-22       Impact factor: 5.082

2.  A Miniature Dual-Biomarker-Based Sensing and Conditioning Device for Closed-Loop DBS.

Authors:  Mahboubeh Parastarfeizabadi; Abbas Z Kouzani
Journal:  IEEE J Transl Eng Health Med       Date:  2019-08-30       Impact factor: 3.316

3.  Sustained efficacy of closed loop electrical stimulation for long-term treatment of absence epilepsy in rats.

Authors:  Gábor Kozák; Antal Berényi
Journal:  Sci Rep       Date:  2017-07-24       Impact factor: 4.379

4.  Development of Electrical Neural Stimulator Generating Periodic and Non-periodic Signals and Supporting Closed-loop Experimental System.

Authors:  Hyejin An; Hyun-Chool Shin
Journal:  Exp Neurobiol       Date:  2018-02-26       Impact factor: 3.261

5.  Dynamiceuticals: The Next Stage in Personalized Medicine.

Authors:  Jose L Perez Velazquez
Journal:  Front Neurosci       Date:  2017-06-07       Impact factor: 4.677

Review 6.  Current Directions in the Auricular Vagus Nerve Stimulation II - An Engineering Perspective.

Authors:  Eugenijus Kaniusas; Stefan Kampusch; Marc Tittgemeyer; Fivos Panetsos; Raquel Fernandez Gines; Michele Papa; Attila Kiss; Bruno Podesser; Antonino Mario Cassara; Emmeric Tanghe; Amine Mohammed Samoudi; Thomas Tarnaud; Wout Joseph; Vaidotas Marozas; Arunas Lukosevicius; Niko Ištuk; Sarah Lechner; Wlodzimierz Klonowski; Giedrius Varoneckas; Jozsef Constantin Széles; Antonio Šarolić
Journal:  Front Neurosci       Date:  2019-07-24       Impact factor: 4.677

7.  A Multi-Channel Asynchronous Neurostimulator With Artifact Suppression for Neural Code-Based Stimulations.

Authors:  Sahar Elyahoodayan; Wenxuan Jiang; Huijing Xu; Dong Song
Journal:  Front Neurosci       Date:  2019-09-27       Impact factor: 4.677

8.  Four-Wire Interface ASIC for a Multi-Implant Link.

Authors:  Sara S Ghoreishizadeh; Dorian Haci; Yan Liu; Nick Donaldson; Timothy G Constandinou
Journal:  IEEE Trans Circuits Syst I Regul Pap       Date:  2017-08-15       Impact factor: 3.605

9.  A new description of epileptic seizures based on dynamic analysis of a thalamocortical model.

Authors:  H Sohanian Haghighi; A H D Markazi
Journal:  Sci Rep       Date:  2017-10-19       Impact factor: 4.379

Review 10.  A Review of Microelectronic Systems and Circuit Techniques for Electrical Neural Recording Aimed at Closed-Loop Epilepsy Control.

Authors:  Reza Ranjandish; Alexandre Schmid
Journal:  Sensors (Basel)       Date:  2020-10-08       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.