Literature DB >> 26571509

Less Invasive and Inotrope-Reduction Approach to Automated Closed-Loop Control of Hemodynamics in Decompensated Heart Failure.

Kazunori Uemura, Toru Kawada, Can Zheng, Masaru Sugimachi.   

Abstract

We have been developing an automated cardiovascular drug infusion system for simultaneous control of arterial pressure (AP), cardiac output (CO), and left atrial pressure (PLA) in decompensated heart failure (HF). In our prototype system, CO and PLA were measured invasively through thoracotomy. Furthermore, the control logic inevitably required use of inotropes to improve hemodynamics, which was not in line with clinical HF guidelines. The goal of this study was to solve these problems and develop a clinically feasible system. We integrated to the system minimally invasive monitors of CO and pulmonary capillary wedge pressure (PCWP, surrogates for PLA) that we developed recently. We also redesigned the control logic to reduce the use of inotrope. We applied the newly developed system to nine dogs with decompensated HF. Once activated, our system started to control the infusion of vasodilator and diuretics in all the animals. Inotrope was not infused in three animals, and infused at minimal doses in six animals that were intolerant of vasodilator infusion alone. Within 50 min, our system controlled AP, CO, and PCWP to their respective targets accurately. Pulmonary artery catheterization confirmed optimization of hemodynamics (AP, from 98 ± 4 to 74 ± 11 mmHg; CO, from 2.2 ± 0.5 to 2.9 ± 0.3 L·min(-1)·m(-2); PCWP, from 27.0 ± 6.6 to 13.8 ± 3.0 mmHg). In a minimally invasive setting while reducing the use of inotrope, our system succeeded in automatically optimizing the overall hemodynamics in canine models of HF. The present results pave the way for clinical application of our automated drug infusion system.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26571509     DOI: 10.1109/TBME.2015.2499782

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  4 in total

Review 1.  Precision diagnosis: a view of the clinical decision support systems (CDSS) landscape through the lens of critical care.

Authors:  Arnaud Belard; Timothy Buchman; Jonathan Forsberg; Benjamin K Potter; Christopher J Dente; Allan Kirk; Eric Elster
Journal:  J Clin Monit Comput       Date:  2016-02-22       Impact factor: 2.502

Review 2.  Automated systems for perioperative goal-directed hemodynamic therapy.

Authors:  Sean Coeckelenbergh; Cedrick Zaouter; Brenton Alexander; Maxime Cannesson; Joseph Rinehart; Jacques Duranteau; Philippe Van der Linden; Alexandre Joosten
Journal:  J Anesth       Date:  2019-09-25       Impact factor: 2.078

3.  Computer-controlled closed-loop drug infusion system for automated hemodynamic resuscitation in endotoxin-induced shock.

Authors:  Kazunori Uemura; Toru Kawada; Can Zheng; Meihua Li; Masaru Sugimachi
Journal:  BMC Anesthesiol       Date:  2017-10-23       Impact factor: 2.217

4.  Development of an automated closed-loop β-blocker delivery system to stably reduce myocardial oxygen consumption without inducing circulatory collapse in a canine heart failure model: a proof of concept study.

Authors:  Takuya Nishikawa; Kazunori Uemura; Yohsuke Hayama; Toru Kawada; Keita Saku; Masaru Sugimachi
Journal:  J Clin Monit Comput       Date:  2021-05-10       Impact factor: 1.977

  4 in total