Correction: Estimation of Instantaneous Gas Exchange in Flow-Through Respirometry Systems: A Modern Revision of Bartholomew's Z-Transform Method.

.   

Abstract

Entities:  

Year:  2015        PMID: 26569097      PMCID: PMC4646692          DOI: 10.1371/journal.pone.0142959

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


× No keyword cloud information.
There is an error in the first sentence of the sixth paragraph of the ZT Method section of the Methods. The publisher apologizes for this error. The correct sentence is: Equation 4 directly determines the instantaneous gas exchange rate (u) from the recorded data: where , and it requires high sampling rate of the outlet gas. In the Generalized ZT (GZT) method section of the Methods, there is an error in the 15th equation. Please view the complete, correct equation here: There is an error in reference 21. The correct reference is: Woakes AJ, and Butler P. J. Swimming and diving in tufted ducks, Aythya fuligula, with particular reference to heart rate and gas exchange. J Exp Biol. 1983;107(1):311–29. There are errors in Tables 1–3. Please see the correct Tables 1–3 here.
Table 1

Parameters of the impulse responses.

Experimentally-determined impulse responses of three respirometry chambers in five different flow rates were modeled in four ways. In the first three models, αtme-βt has been fitted to the data. Here m, α, and β are constant parameters that are needed to fit this curve (αtme-βt) to the experimental data (see text for details). In the first one, m is considered as a real number. In the second, one we restricted the m to be an integer and then found the parameters. In the third one, we decreased m to the lowest integer number without having more than 10% ITAE (). In the last one, we forced m to be zero in order to recover the ZT model.

Best fit curveEZT methodZT method
Best integer m Small m (m = 0)
V(mL)F(mL/min) m β (1/s) δ (s) m β δ m β δ β δ
281251.650.18812.7520.20612.0510.1514.160.06616.62
282500.970.2465.8710.2495.8210.2495.820.10947.204
285001.160.494.0810.4594.1910.4594.190.20185.025
2812502.852.0891.532.1421.4721.7611.680.56572.236
28250014.26.580.29146.530.2933.0450.790.80911.338
1251250.860.05418.910.05718.0910.05718.090.244123.95
1252501.830.17810.5820.18510.210.13412.510.057515.15
1255001.120.2466.2710.2346.4410.2346.440.10118.0
12512500.350.2912.4600.1892.7400.1892.740.18922.74
12525000.670.5921.4210.6991.2610.6991.260.30571.77
6001250.0260.00529.3600.003529.7500.003529.750.003529.75
6002500.0480.01119.9100.010220.4600.010220.460.010220.46
6005000.1440.02713.8300.021714.6500.021714.650.021714.65
60012500.2060.04214.3600.031315.3300.031315.330.031315.33
60025000.2040.1313.0300.09693.2600.09693.260.09683.26
Table 3

Normalized ITAE to the area of the input signal of the recovered signals in different frequencies.

Normalized ITAE
MethodF(mL/mi)0.1 Hz0.167Hz0.25 Hz0.5 Hz1 Hz
ZT2501.17671.16671.16831.53751.6032
EZT2500.75770.68890.80731.22681.3170
GZT2500.32690.40960.47570.78621.2056
ZT5000.45000.79040.94961.12641.4902
EZT5000.37240.54000.90041.21141.4116
GZT5000.26990.48550.50100.72041.3549

Parameters of the impulse responses.

Experimentally-determined impulse responses of three respirometry chambers in five different flow rates were modeled in four ways. In the first three models, αtme-βt has been fitted to the data. Here m, α, and β are constant parameters that are needed to fit this curve (αtme-βt) to the experimental data (see text for details). In the first one, m is considered as a real number. In the second, one we restricted the m to be an integer and then found the parameters. In the third one, we decreased m to the lowest integer number without having more than 10% ITAE (). In the last one, we forced m to be zero in order to recover the ZT model.
Table 2

Estimated parameters of ZT and EZT methods using Eqs 2 and 11 and from experimental data.

MethodF(mL/min)Parameterestimation methoda1 a2
ZT250Equation 26.72-
ZT250Experiment12.2-
ZT500Equation 23.36-
ZT500Experiment5.3-
EZT250Equation 128.0316.13
EZT250Experiment12.341.2
EZT500Equation 124.364.75
EZT500Experiment5.25.1
  1 in total

1.  Estimation of Instantaneous Gas Exchange in Flow-Through Respirometry Systems: A Modern Revision of Bartholomew's Z-Transform Method.

Authors:  Hodjat Pendar; John J Socha
Journal:  PLoS One       Date:  2015-10-14       Impact factor: 3.240