The Kinect Recording System for objective three- and four-dimensional breast assessment with image overlays.

Helga Henseler1, Sarah Kim Bonkat2, Peter Maria Vogt3, Bodo Rosenhahn4.   

Abstract

INTRODUCTION: We investigated the application of the validated portable Kinect camera for three- and four-dimensional breast assessment in female life models.
METHOD: Breast images from six life models were captured using the Kinect camera. Capture was conducted with taking three different arm positions while standing upright: with the arms straight down, straight up to the side at 90° and straight all the way up. Images of the volunteers were superimposed on each other. Digital linear distances between sternal notch and nipple-areola complexes were obtained and compared. The views of plastic and breast surgeons to arm positions were questioned. An example for clinical application was provided.
RESULTS: Successful capture of images of the female life breast models was achieved. Digital breast measurements at the three different arm positions revealed considerable variation in linear distances measured on the images obtained with the Kinect camera. The dynamic of breast movements could be demonstrated by image overlay and the first ever four-dimensional breast assessment was demonstrated. Fourteen plastic and breast surgeons were found to have nine different opinions regarding their favoured arm positions for breast capture. Even though precision of image sharpness still needs improvement, the images were satisfactory for clinical patient use. The Kinect data were shown to be applicable to surgery planning by designing a planar flap from the 3D mesh.
CONCLUSION: The portable and low-cost Kinect camera proved to be easy to use for the first application in life models for three- and four-dimensional breast assessment.
Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Arm positioning; Breast assessment; Flap planning; Kinect; Objective method; Three-dimensional imaging

Mesh:

Year:  2015        PMID: 26565080     DOI: 10.1016/j.bjps.2015.10.021

Source DB:  PubMed          Journal:  J Plast Reconstr Aesthet Surg        ISSN: 1748-6815            Impact factor:   2.740


  2 in total

1.  Auricular Total Reconstruction with Radial Forearm Prelaminated Flap Assisted by 3D Surface Imaging and 3D Printing.

Authors:  Marco Aurelio Rendón-Medina; Erik Hanson-Viana; Leidy Arias-Salazar; Jorge Arturo Rojas-Ortiz; Maria de Los Angeles Mendoza-Velez; Rubén Hernandez-Ordoñez; Hecly Lya Vázquez-Morales; Ricardo C Pacheco-López
Journal:  Plast Reconstr Surg Glob Open       Date:  2022-10-13

2.  Structured-light surface scanning system to evaluate breast morphology in standing and supine positions.

Authors:  Olivia L H Tong; Astrid Chamson-Reig; Lawrence C M Yip; Muriel Brackstone; Mamadou Diop; Jeffrey J L Carson
Journal:  Sci Rep       Date:  2020-08-24       Impact factor: 4.379

  2 in total