[EOS imaging acquisition system : 2D/3D diagnostics of the skeleton].

T Tarhan1, D Froemel2, A Meurer2.   

Abstract

The application spectrum of the EOS imaging acquisition system is versatile. It is especially useful in the diagnostics and planning of corrective surgical procedures in complex orthopedic cases. The application is indicated when assessing deformities and malpositions of the spine, pelvis and lower extremities. It can also be used in the assessment and planning of hip and knee arthroplasty. For the first time physicians have the opportunity to conduct examinations of the whole body under weight-bearing conditions in order to anticipate the effects of a planned surgical procedure on the skeletal system as a whole and therefore on the posture of the patient. Compared to conventional radiographic examination techniques, such as x-ray or computed tomography, the patient is exposed to much less radiation. Therefore, the pediatric application of this technique can be described as reasonable.

Entities:  

Keywords:  Arthroplasty; Deformity; Pelvis; Radiation exposure; Spine

Mesh:

Year:  2015        PMID: 26564207     DOI: 10.1007/s00132-015-3186-9

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  16 in total

1.  Evaluating Length: The Use of Low-dose Biplanar Radiography (EOS) and Tantalum Bead Implantation.

Authors:  Matthew R Garner; Matthew Dow; Elise Bixby; Doug N Mintz; Roger F Widmann; Emily R Dodwell
Journal:  J Pediatr Orthop       Date:  2016-01       Impact factor: 2.324

2.  [EOS stereo-radiography system: whole-body simultaneous anteroposterior and lateral radiographs with very low radiation dose].

Authors:  J Dubousset; G Charpak; W Skalli; G Kalifa; J-Y Lazennec
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2007-10

3.  Ionizing radiation doses during lower limb torsion and anteversion measurements by EOS stereoradiography and computed tomography.

Authors:  Cyrille Delin; Stéphane Silvera; Céline Bassinet; Philippe Thelen; Jean-Luc Rehel; Paul Legmann; Dominique Folinais
Journal:  Eur J Radiol       Date:  2013-11-07       Impact factor: 3.528

4.  Diagnosis of vertebral fractures using a low-dose biplanar imaging system.

Authors:  K Briot; J Fechtenbaum; A Etcheto; S Kolta; A Feydy; C Roux
Journal:  Osteoporos Int       Date:  2015-06-06       Impact factor: 4.507

Review 5.  EOS 2D/3D X-ray imaging system: a systematic review and economic evaluation.

Authors:  C McKenna; R Wade; R Faria; H Yang; L Stirk; N Gummerson; M Sculpher; N Woolacott
Journal:  Health Technol Assess       Date:  2012       Impact factor: 4.014

Review 6.  Musculoskeletal imaging in progress: the EOS imaging system.

Authors:  Marc Wybier; Philippe Bossard
Journal:  Joint Bone Spine       Date:  2012-11-22       Impact factor: 4.929

7.  Pelvis and total hip arthroplasty acetabular component orientations in sitting and standing positions: measurements reproductibility with EOS imaging system versus conventional radiographies.

Authors:  J Y Lazennec; M A Rousseau; A Rangel; M Gorin; C Belicourt; A Brusson; Y Catonné
Journal:  Orthop Traumatol Surg Res       Date:  2011-05-12       Impact factor: 2.256

8.  Diagnostic imaging of spinal deformities: reducing patients radiation dose with a new slot-scanning X-ray imager.

Authors:  Sylvain Deschênes; Guy Charron; Gilles Beaudoin; Hubert Labelle; Josée Dubois; Marie-Claude Miron; Stefan Parent
Journal:  Spine (Phila Pa 1976)       Date:  2010-04-20       Impact factor: 3.468

9.  Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography.

Authors:  Tobias J Dietrich; Christian W A Pfirrmann; Alexander Schwab; Katja Pankalla; Florian M Buck
Journal:  Skeletal Radiol       Date:  2013-03-28       Impact factor: 2.199

10.  Assessment of prosthesis alignment after revision total knee arthroplasty using EOS 2D and 3D imaging: a reliability study.

Authors:  Marrigje F Meijer; Alexander L Boerboom; Martin Stevens; Sjoerd K Bulstra; Inge H F Reininga
Journal:  PLoS One       Date:  2014-09-23       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.