Graphite Screen-Printed Electrodes Applied for the Accurate and Reagentless Sensing of pH.

Flávia E Galdino1,2, Jamie P Smith2, Sophie I Kwamou3, Dimitrios K Kampouris2, Jesus Iniesta4, Graham C Smith5, Juliano A Bonacin1, Craig E Banks2.   

Abstract

A reagentless pH sensor based upon disposable and economical graphite screen-printed electrodes (GSPEs) is demonstrated for the first time. The voltammetric pH sensor utilizes GSPEs which are chemically pretreated to form surface immobilized oxygenated species that, when their redox behavior is monitored, give a Nernstian response over a large pH range (1-13). An excellent experimental correlation is observed between the voltammetric potential and pH over the entire pH range of 1-13 providing a simple approach with which to monitor solution pH. Such a linear response over this dynamic pH range is not usually expected but rather deviation from linearity is encountered at alkaline pH values; absence of this has previously been attributed to a change in the pKa value of surface immobilized groups from that of solution phase species. This non-deviation, which is observed here in the case of our facile produced reagentless pH sensor and also reported in the literature for pH sensitive compounds immobilized upon carbon electrodes/surfaces, where a linear response is observed over the entire pH range, is explained alternatively for the first time. The performance of the GSPE pH sensor is also directly compared with a glass pH probe and applied to the measurement of pH in "real" unbuffered samples where an excellent correlation between the two protocols is observed validating the proposed GSPE pH sensor.

Entities:  

Year:  2015        PMID: 26561992     DOI: 10.1021/acs.analchem.5b01236

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  Exploring carbon particle type and plasma treatment to improve electrochemical properties of stencil-printed carbon electrodes.

Authors:  Alyssa A Kava; Charles S Henry
Journal:  Talanta       Date:  2020-09-01       Impact factor: 6.057

2.  A prototype device of microliter volume voltammetric pH sensor based on carbazole-quinone redox-probe tethered MWCNT modified three-in-one screen-printed electrode.

Authors:  Sakthivel Srinivas; Krishnan Ashokkumar; Kamaraj Sriraghavan; Annamalai Senthil Kumar
Journal:  Sci Rep       Date:  2021-07-06       Impact factor: 4.379

  2 in total