Sung-Jin Hong1, Byeong-Keuk Kim2, Dong-Ho Shin2, Chung-Mo Nam3, Jung-Sun Kim2, Young-Guk Ko2, Donghoon Choi2, Tae-Soo Kang4, Woong-Chol Kang5, Ae-Young Her6, Yong Hoon Kim6, Yonghoon Kim6, Seung-Ho Hur7, Bum-Kee Hong8, Hyuckmoon Kwon8, Yangsoo Jang9, Myeong-Ki Hong9. 1. Department of Internal Medicine, Sanggye Paik Hospital, Inje University, Seoul, Korea2Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea. 2. Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea. 3. Department of Preventive Medicine and Biostatistics, Yonsei University College of Medicine, Seoul, Korea. 4. Dankook University College of Medicine, Cheonan, Korea. 5. Gil Hospital, Gachon University College of Medicine, Incheon, Korea. 6. School of Medicine, Kangwon National University, Chuncheon, Korea. 7. Keimyung University College of Medicine, Daegu, Korea. 8. Kangnam Severance Hospital, Seoul, Korea. 9. Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea9Severance Biomedical Science Institute, Yonsei University College of Medicine, Seoul, Korea10Cardiovascular Research Institute, Yonsei Universit.
Abstract
IMPORTANCE: Use of intravascular ultrasound (IVUS) promotes better clinical outcomes for coronary intervention in complex coronary lesions. However, randomized data demonstrating the clinical usefulness of IVUS are limited for lesions treated with drug-eluting stents. OBJECTIVE: To determine whether the long-term clinical outcomes with IVUS-guided drug-eluting stent implantation are superior to those with angiography-guided implantation in patients with long coronary lesions. DESIGN, SETTING, AND PARTICIPANTS: The Impact of Intravascular Ultrasound Guidance on Outcomes of Xience Prime Stents in Long Lesions (IVUS-XPL) randomized, multicenter trial was conducted in 1400 patients with long coronary lesions (implanted stent ≥28 mm in length) between October 2010 and July 2014 at 20 centers in Korea. INTERVENTIONS: Patients were randomly assigned to receive IVUS-guided (n = 700) or angiography-guided (n = 700) everolimus-eluting stent implantation. MAIN OUTCOMES AND MEASURES: Primary outcome measure was the composite of major adverse cardiac events, including cardiac death, target lesion-related myocardial infarction, or ischemia-driven target lesion revascularization at 1 year, analyzed by intention-to-treat. RESULTS: One-year follow-up was complete in 1323 patients (94.5%). Major adverse cardiac events at 1 year occurred in 19 patients (2.9%) undergoing IVUS-guided and in 39 patients (5.8%) undergoing angiography-guided stent implantation (absolute difference, -2.97% [95% CI, -5.14% to -0.79%]) (hazard ratio [HR], 0.48 [95% CI, 0.28 to 0.83], P = .007). The difference was driven by a lower risk of ischemia-driven target lesion revascularization in patients undergoing IVUS-guided (17 [2.5%]) compared with angiography-guided (33 [5.0%]) stent implantation (HR, 0.51 [95% CI, 0.28 to 0.91], P = .02). Cardiac death and target lesion-related myocardial infarction were not significantly different between the 2 groups. For cardiac death, there were 3 patients (0.4%) in the IVUS-guided group and 5 patients (0.7%) in the angiography-guided group (HR, 0.60 [95% CI, 0.14 to 2.52], P = .48). Target lesion-related myocardial infarction occurred in 1 patient (0.1%) in the angiography-guided stent implantation group (P = .32). CONCLUSIONS AND RELEVANCE: Among patients requiring long coronary stent implantation, the use of IVUS-guided everolimus-eluting stent implantation, compared with angiography-guided stent implantation, resulted in a significantly lower rate of the composite of major adverse cardiac events at 1 year. These differences were primarily due to lower risk of target lesion revascularization. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01308281.
RCT Entities:
IMPORTANCE: Use of intravascular ultrasound (IVUS) promotes better clinical outcomes for coronary intervention in complex coronary lesions. However, randomized data demonstrating the clinical usefulness of IVUS are limited for lesions treated with drug-eluting stents. OBJECTIVE: To determine whether the long-term clinical outcomes with IVUS-guided drug-eluting stent implantation are superior to those with angiography-guided implantation in patients with long coronary lesions. DESIGN, SETTING, AND PARTICIPANTS: The Impact of Intravascular Ultrasound Guidance on Outcomes of Xience Prime Stents in Long Lesions (IVUS-XPL) randomized, multicenter trial was conducted in 1400 patients with long coronary lesions (implanted stent ≥28 mm in length) between October 2010 and July 2014 at 20 centers in Korea. INTERVENTIONS:Patients were randomly assigned to receive IVUS-guided (n = 700) or angiography-guided (n = 700) everolimus-eluting stent implantation. MAIN OUTCOMES AND MEASURES: Primary outcome measure was the composite of major adverse cardiac events, including cardiac death, target lesion-related myocardial infarction, or ischemia-driven target lesion revascularization at 1 year, analyzed by intention-to-treat. RESULTS: One-year follow-up was complete in 1323 patients (94.5%). Major adverse cardiac events at 1 year occurred in 19 patients (2.9%) undergoing IVUS-guided and in 39 patients (5.8%) undergoing angiography-guided stent implantation (absolute difference, -2.97% [95% CI, -5.14% to -0.79%]) (hazard ratio [HR], 0.48 [95% CI, 0.28 to 0.83], P = .007). The difference was driven by a lower risk of ischemia-driven target lesion revascularization in patients undergoing IVUS-guided (17 [2.5%]) compared with angiography-guided (33 [5.0%]) stent implantation (HR, 0.51 [95% CI, 0.28 to 0.91], P = .02). Cardiac death and target lesion-related myocardial infarction were not significantly different between the 2 groups. For cardiac death, there were 3 patients (0.4%) in the IVUS-guided group and 5 patients (0.7%) in the angiography-guided group (HR, 0.60 [95% CI, 0.14 to 2.52], P = .48). Target lesion-related myocardial infarction occurred in 1 patient (0.1%) in the angiography-guided stent implantation group (P = .32). CONCLUSIONS AND RELEVANCE: Among patients requiring long coronary stent implantation, the use of IVUS-guided everolimus-eluting stent implantation, compared with angiography-guided stent implantation, resulted in a significantly lower rate of the composite of major adverse cardiac events at 1 year. These differences were primarily due to lower risk of target lesion revascularization. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01308281.
Authors: Christopher R Kelly; Paul S Teirstein; Ian T Meredith; Bruno Farah; Christophe L Dubois; Robert L Feldman; Joseph Dens; Nobuhisa Hagiwara; Abram Rabinowitz; Didier Carrié; Vincent Pompili; Alain Bouchard; Shigeru Saito; Dominic J Allocco; Keith D Dawkins; Gregg W Stone Journal: JACC Cardiovasc Interv Date: 2017-12-11 Impact factor: 11.195