Literature DB >> 26555799

Sextant-Specific Analysis of Detection and Tumor Volume by HistoScanning™.

Daniel Porres1, Timur Hasan Kuru, Robin Epplen, Andreas Eck, Vahudin Zugor, Lieven Niels Kennes, Samir Afram, Till Braunschweig, Ruth Knüchel-Clarke, David Pfister, Axel Heidenreich.   

Abstract

INTRODUCTION: Published results of HistoScanning™ (HS) for prostate cancer (PCa) diagnostics are inconsistent and their value remains unclear. We prospectively analyzed the detection rate and tumor volume concordance in PCa patients.
MATERIAL AND METHODS: Two hundred and eighty-two patients with biopsy-proven PCa scheduled for radical prostatectomy (RP) were included. All patients underwent ultrasonographical examination by HS prior to surgery. HS was evaluated compared to RP specimen as to (1) the prediction of overall tumor volume and (2) accuracy of HS in detection of PCa lesions larger than 0.2/0.5 ml, separated for each sextant. For each sextant, receiver operating characteristic (ROC)-analysis and area under the curve were determined. Sensitivity and specificity were calculated and visualized in ROC-curves.
RESULTS: HS tends to underestimate volume of cancerous lesions, particularly larger lesions >8 ml. Using a 0.2 ml detection threshold, specificity and sensitivity of HS were between 29-68% and 46-78%. For a 0.5 ml detection threshold, sextant-specific specificity increased to 59-92% and sensitivity decreased to 16-54%. Stratification according to pre-operational PSA values did not improve performance characteristics of HS.
CONCLUSIONS: Our results do not support a significant contribution of HS to PCa diagnostics.
© 2015 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2015        PMID: 26555799     DOI: 10.1159/000440814

Source DB:  PubMed          Journal:  Urol Int        ISSN: 0042-1138            Impact factor:   2.089


  3 in total

Review 1.  HistoScanningTM to Detect and Characterize Prostate Cancer-a Review of Existing Literature.

Authors:  James S Wysock; Alex Xu; Clement Orczyk; Samir S Taneja
Journal:  Curr Urol Rep       Date:  2017-10-24       Impact factor: 3.092

2.  A systematic review and meta-analysis of Histoscanning™ in prostate cancer diagnostics.

Authors:  Andrey Morozov; Vasiliy Kozlov; Juan Gomez Rivas; Jeremy Yuen-Chun Teoh; Evgeniy Bezrukov; Alexander Amosov; Eric Barret; Mark Taratkin; Georg Salomon; Thomas R W Herrmann; Ali Gozen; Dmitry Enikeev
Journal:  World J Urol       Date:  2021-04-07       Impact factor: 4.226

3.  Application of ultrasound imaging biomarkers (HistoScanning™) improves staging reliability of prostate biopsies.

Authors:  M F Hamann; D Meyer; S Knüpfer; J Fuchs; K P Jünemann; C M Naumann
Journal:  BMC Res Notes       Date:  2017-11-09
  3 in total