Literature DB >> 26552084

Adaptive Light Modulation for Improved Resolution and Efficiency in All-Optical Pulse-Echo Ultrasound.

Erwin J Alles, Richard J Colchester, Adrien E Desjardins.   

Abstract

In biomedical all-optical pulse-echo ultrasound systems, ultrasound is generated with the photoacoustic effect by illuminating an optically absorbing structure with a temporally modulated light source. Nanosecond range laser pulses are typically used, which can yield bandwidths exceeding 100 MHz. However, acoustical attenuation within tissue or nonuniformities in the detector or source power spectra result in energy loss at the affected frequencies and in a reduced overall system efficiency. In this work, a laser diode is used to generate linear and nonlinear chirp optical modulations that are extended to microsecond time scales, with bandwidths constrained to the system sensitivity. Compared to those obtained using a 2-ns pulsed laser, pulse-echo images of a phantom obtained using linear chirp excitation exhibit similar axial resolution (99 versus 92 μm, respectively) and signal-to-noise ratios (SNRs) (10.3 versus 9.6 dB). In addition, the axial point spread function (PSF) exhibits lower sidelobe levels in the case of chirp modulation. Using nonlinear (time-stretched) chirp excitations, where the nonlinearity is computed from measurements of the spectral sensitivity of the system, the power spectrum of the imaging system was flattened and its bandwidth broadened. Consequently, the PSF has a narrower axial extent and still lower sidelobe levels. Pulse-echo images acquired with time-stretched chirps as optical modulation have higher axial resolution (64 μm) than those obtained with linear chirps, at the expense of a lower SNR (6.8 dB). Using a linear or time-stretched chirp, the conversion efficiency from optical power to acoustical pressure improved by a factor of 70 or 61, respectively, compared to that obtained with pulsed excitation.

Mesh:

Year:  2015        PMID: 26552084     DOI: 10.1109/TUFFC.2015.2497465

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  7 in total

1.  A reconfigurable all-optical ultrasound transducer array for 3D endoscopic imaging.

Authors:  Erwin J Alles; Nora Fook Sheung; Sacha Noimark; Edward Z Zhang; Paul C Beard; Adrien E Desjardins
Journal:  Sci Rep       Date:  2017-04-26       Impact factor: 4.379

Review 2.  Optical Ultrasound Generation and Detection for Intravascular Imaging: A Review.

Authors:  Tianrui Zhao; Lei Su; Wenfeng Xia
Journal:  J Healthc Eng       Date:  2018-04-30       Impact factor: 2.682

3.  All-Optical Rotational Ultrasound Imaging.

Authors:  Richard J Colchester; Callum Little; George Dwyer; Sacha Noimark; Erwin J Alles; Edward Z Zhang; Christopher D Loder; Ivan P Parkin; Ioannis Papakonstantinou; Paul C Beard; Malcolm C Finlay; Roby D Rakhit; Adrien E Desjardins
Journal:  Sci Rep       Date:  2019-04-03       Impact factor: 4.379

4.  Pencil beam all-optical ultrasound imaging.

Authors:  Erwin J Alles; Sacha Noimark; Edward Zhang; Paul C Beard; Adrien E Desjardins
Journal:  Biomed Opt Express       Date:  2016-08-26       Impact factor: 3.732

5.  Handheld Real-Time LED-Based Photoacoustic and Ultrasound Imaging System for Accurate Visualization of Clinical Metal Needles and Superficial Vasculature to Guide Minimally Invasive Procedures.

Authors:  Wenfeng Xia; Mithun Kuniyil Ajith Singh; Efthymios Maneas; Naoto Sato; Yusuke Shigeta; Toshitaka Agano; Sebastian Ourselin; Simeon J West; Adrien E Desjardins
Journal:  Sensors (Basel)       Date:  2018-05-01       Impact factor: 3.576

6.  Through-needle all-optical ultrasound imaging in vivo: a preclinical swine study.

Authors:  Malcolm C Finlay; Charles A Mosse; Richard J Colchester; Sacha Noimark; Edward Z Zhang; Sebastien Ourselin; Paul C Beard; Richard J Schilling; Ivan P Parkin; Ioannis Papakonstantinou; Adrien E Desjardins
Journal:  Light Sci Appl       Date:  2017-12-01       Impact factor: 17.782

7.  Video-rate all-optical ultrasound imaging.

Authors:  Erwin J Alles; Sacha Noimark; Efthymios Maneas; Edward Z Zhang; Ivan P Parkin; Paul C Beard; Adrien E Desjardins
Journal:  Biomed Opt Express       Date:  2018-07-02       Impact factor: 3.732

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.