Literature DB >> 26550610

Determination of Crystalline Silica in Dust at Low Concentrations by Low-Temperature Infrared Spectrometry.

William P Chisholm1, Taekhee Lee, Madalina Chirila.   

Abstract

The American Conference of Governmental Industrial Hygienists (ACGIH) accepted a lower threshold limit value (TLV) for respirable crystalline silica (RCS) exposure of 25 μg/m3, half of the previous TLV. This change is problematic because the current standard sampling and measurement practices used by NIOSH, OSHA, and MSHA are not sensitive enough to allow an analyst to confidently determine samples acquired near the TLV. In response to this need for a more sensitive method to analyze respirable dust filter samples for crystalline silica, a modification of current NIOSH infrared spectrometric methods is being developed. The additional sensitivity is gained by performing the infrared absorbance measurements at 77 K where absorbance peaks are more intense by virtue of being narrower. A quick-change cryostat has been fabricated such that a sample can be introduced to the spectrometer and cooled to 77 K in 5 min, interrogated for 1 min, and removed and the cryostat readied for another sample in 2 min, for a turnaround time of 8 min per sample, which is brief compared to the time required to prepare and redeposit a sample. Therefore, samples can be acquired and interrogated with legacy samplers, filters, pumps, spectrometers, and sample preparation, the only modification being the addition of a cryostat to the spectrometer. Preliminary experiments demonstrate that the peak-to-background ratio of the quartz signature band near 800 cm-1 increases by approximately 50 % on cooling from room temperature to 77 K. The slopes of the calibration curve derived from standards interrogated at both room temperature and 77 K indicate that the low-temperature method is approximately 25 % more sensitive.

Entities:  

Keywords:  FTIR; respirable quartz dust; silica dust

Year:  2013        PMID: 26550610      PMCID: PMC4635073          DOI: 10.1520/STP156520130029

Source DB:  PubMed          Journal:  Annu Book ASTM Stand Sect 11 Water Environ Technol


  7 in total

1.  Comparison by X-ray diffraction and infrared spectroscopy of two samples of alpha quartz with the NIST SRM 1878a alpha quartz.

Authors:  E Kauffer; J C Moulut; A Masson; J C Protois; M Grzebyk
Journal:  Ann Occup Hyg       Date:  2002-06

2.  Risk assessment of silicosis and lung cancer among construction workers exposed to respirable quartz.

Authors:  Evelyn Tjoe Nij; Dick Heederik
Journal:  Scand J Work Environ Health       Date:  2005       Impact factor: 5.024

Review 3.  Pooled exposure-response analyses and risk assessment for lung cancer in 10 cohorts of silica-exposed workers: an IARC multicentre study.

Authors:  K Steenland; A Mannetje; P Boffetta; L Stayner; M Attfield; J Chen; M Dosemeci; N DeKlerk; E Hnizdo; R Koskela; H Checkoway
Journal:  Cancer Causes Control       Date:  2001-11       Impact factor: 2.506

4.  A comparison of the performance of samplers for respirable dust in workplaces and laboratory analysis for respirable quartz.

Authors:  Steven Verpaele; Jonathan Jouret
Journal:  Ann Occup Hyg       Date:  2012-07-23

Review 5.  Issues and controversy: the measurement of crystalline silica; review papers on analytical methods.

Authors:  W J Miles
Journal:  Am Ind Hyg Assoc J       Date:  1999 May-Jun

6.  Silica, Some Silicates, Coal Dust and Para-Aramid Fibrils.

Authors: 
Journal:  IARC Monogr Eval Carcinog Risks Hum       Date:  1997

7.  Silica, silicosis and lung-cancer: results from a cohort study in the stone and quarry industry.

Authors:  K Ulm; P Gerein; J Eigenthaler; S Schmidt; H Ehnes
Journal:  Int Arch Occup Environ Health       Date:  2004-05-20       Impact factor: 3.015

  7 in total
  1 in total

1.  An In Vivo Comparison: Novel Mesh Suture Versus Traditional Suture-Based Repair in a Rabbit Tendon Model.

Authors:  Lindsay E Janes; Lauren M Mioton; Megan E Fracol; Jason H Ko
Journal:  J Hand Surg Glob Online       Date:  2021-11-19
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.