Literature DB >> 26550073

Inferior vena cava collapsibility loses correlation with internal jugular vein collapsibility during increased thoracic or intra-abdominal pressure.

Zachary Bauman1, Victor Coba1, Marika Gassner1, David Amponsah1, John Gallien1, Dionne Blyden1, Keith Killu1.   

Abstract

PURPOSE: Point-of-care ultrasound evaluates inferior vena cava (IVC) and internal jugular vein (IJV) measurements to estimate intravascular volume status. The reliability of the IVC and IJV collapsibility index during increased thoracic or intra-abdominal pressure remains unclear.
METHODS: Three phases of sonographic scanning were performed: spontaneous breathing phase, increased thoracic pressure phase via positive pressure ventilation (PPV) phase, and increased intra-abdominal pressure (IAP) phase via laparoscopic insufflation to 15 mmHg. IVC measurements were done at 1-2 cm below the diaphragm and IJV measurements were done at the level of the cricoid cartilage during a complete respiratory cycle. Collapsibility index was calculated by (max diameter - min diameter)/max diameter × 100 %. Chi square, t test, correlation procedure (CORR) and Fisher's exact analyses were completed.
RESULTS: A total of 144 scans of the IVC and IJV were completed in 16 patients who underwent laparoscopic surgery. Mean age was 46 ± 15 years, with 75 % female and 69 % African-American. IVC and IJV collapsibility correlated in the setting of spontaneous breathing (r (2) = 0.86, p < 0.01). IVC collapsibility had no correlation with the IJV in the setting of PPV (r (2) = 0.21, p = 0.52) or IAP (r (2) = 0.26, p = 0.42). Maximal IVC diameter was significantly smaller during increased IAP (16.5 mm ± 4.9) compared to spontaneous breathing (20.6 mm ± 4.8, p = 0.04) and PPV (21.8 mm ± 5.6, p = 0.01).
CONCLUSION: IJV and IVC collapsibility correlated during spontaneous breathing but there was no statistically significant correlation during increased thoracic or intra-abdominal pressure. Increased intra-abdominal pressure was associated with a significant smaller maximal IVC diameter and cautions the reliability of IVC diameter in clinical settings that are associated with intra-abdominal hypertension or abdominal compartment syndrome.

Entities:  

Keywords:  Abdominal compartment syndrome; Collapsibility Index; Inferior vena cava; Internal jugular vein; Intra-abdominal hypertension; Ultrasound

Year:  2015        PMID: 26550073      PMCID: PMC4630271          DOI: 10.1007/s40477-015-0181-2

Source DB:  PubMed          Journal:  J Ultrasound        ISSN: 1876-7931


  19 in total

1.  Inferior vena cava distensibility as a predictor of fluid responsiveness in patients with subarachnoid hemorrhage.

Authors:  Riccardo Moretti; Barbara Pizzi
Journal:  Neurocrit Care       Date:  2010-08       Impact factor: 3.210

2.  The effect of breathing manner on inferior vena caval diameter.

Authors:  Bruce J Kimura; Randy Dalugdugan; Glynn W Gilcrease; James N Phan; Brian K Showalter; Tanya Wolfson
Journal:  Eur J Echocardiogr       Date:  2010-10-27

Review 3.  Abdominal compartment syndrome.

Authors:  Michael Sugrue
Journal:  Curr Opin Crit Care       Date:  2005-08       Impact factor: 3.687

4.  Inferior vena cava diameter correlates with invasive hemodynamic measures in mechanically ventilated intensive care unit patients with sepsis.

Authors:  Joerg C Schefold; Christian Storm; Sven Bercker; Rene Pschowski; Michael Oppert; Anne Krüger; Dietrich Hasper
Journal:  J Emerg Med       Date:  2008-04-01       Impact factor: 1.484

5.  Hemodynamic changes during laparoscopic gastric bypass procedures.

Authors:  Dominick Artuso; Michael Wayne; Sebastiano Cassaro; Thomas Cerabona; Julio Teixeira; Robert Grossi
Journal:  Arch Surg       Date:  2005-03

6.  Assessment of right atrial pressure using echocardiography and correlation with catheterization.

Authors:  Ozlem Yildirimturk; Yelda Tayyareci; Refik Erdim; Ersin Ozen; Selen Yurdakul; Vedat Aytekin; Ic Cemsid Demiroglu; Saide Aytekin
Journal:  J Clin Ultrasound       Date:  2011-05-04       Impact factor: 0.910

7.  Does bedside sonographic measurement of the inferior vena cava diameter correlate with central venous pressure in the assessment of intravascular volume in children?

Authors:  Lorraine Ng; Hnin Khine; Benjamin H Taragin; Jeffrey R Avner; Michael Ushay; Denise Nunez
Journal:  Pediatr Emerg Care       Date:  2013-03       Impact factor: 1.454

8.  Haemodynamic, acid-base and blood volume changes during prolonged low pressure pneumoperitoneum in rabbits.

Authors:  R Sümpelmann; T Schuerholz; G Marx; D Härtel; H Hecker; B M Ure; N K Jesch
Journal:  Br J Anaesth       Date:  2006-03-10       Impact factor: 9.166

9.  Inferior vena cava collapsibility to guide fluid removal in slow continuous ultrafiltration: a pilot study.

Authors:  Giovanna Guiotto; Mario Masarone; Fiorella Paladino; Enrico Ruggiero; Sean Scott; Sossio Verde; Fernando Schiraldi
Journal:  Intensive Care Med       Date:  2010-01-22       Impact factor: 17.440

10.  Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients.

Authors:  Christophe Barbier; Yann Loubières; Christophe Schmit; Jan Hayon; Jean-Louis Ricôme; François Jardin; Antoine Vieillard-Baron
Journal:  Intensive Care Med       Date:  2004-03-18       Impact factor: 17.440

View more
  3 in total

1.  Comparison of Respiratory Variations of Subclavian Vein and Inferior Vena Cava in Hospitalized Patients with Kidney Disease.

Authors:  Elaine M Kaptein; Alan Cantillep; John S Kaptein; Zayar Oo; Myint B Thu; Phyu Phyu Thwe; Matthew J Kaptein
Journal:  Int J Nephrol Renovasc Dis       Date:  2020-11-10

Review 2.  The utility of point-of-care ultrasound in the assessment of volume status in acute and critically ill patients.

Authors:  Ali Pourmand; Matthew Pyle; David Yamane; Kazi Sumon; Sarah E Frasure
Journal:  World J Emerg Med       Date:  2019

3.  Sonographic Assessment of Intravascular Fluid Estimate (SAFE) Score by Using Bedside Ultrasound in the Intensive Care Unit.

Authors:  Keith Killu; Victor Coba; Dionne Blyden; Semeret Munie; Darlene Dereczyk; Pridvi Kandagatla; Amy Tang
Journal:  Crit Care Res Pract       Date:  2020-02-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.