Literature DB >> 26549808

A Single-Center Experience of Aortic and Iliac Artery Aneurysm Treated with Multilayer Flow Modulator.

Bianca Pane1, Giovanni Spinella2, Cecilia Perfumo1, Domenico Palombo1.   

Abstract

BACKGROUND: The aim of this study was to analyze our series of endovascular treatments using a multilayer flow modulator (MFM) and to show the midterm results.
METHODS: At our institution, 8 patients were treated with an MFM. Four patients presented with an aortic aneurysm (2 type II thoracoabdominal aortic aneurysms [TAAAs], 1 type IV TAAA, and 1 juxtarenal abdominal aortic aneurysm) and 4 with an aneurysm involving the common iliac artery. Mortality, rupture and secondary intervention, major complications, patency of collateral vessels, and volume analysis were evaluated. Treated patients were followed up with computed tomography angiography at 1, 3, 6, and 12 months.
RESULTS: Results showed no 30-day mortality or major complications; technical success was achieved in 87.5% of patients, patency of collateral vessels was reached in all cases at intraoperative completion angiography. Mean follow-up was 22.1 months (range, 18-30), survival rate was 87.5%, and one case of death unrelated to MFM treatment was reported. During follow-up, MFM and collateral vessel patency were observed in all cases. Secondary endovascular or open surgical procedures were not needed during follow-up. Volume analysis showed a slight increase in patients with aortic aneurysm, and an overall trend to increase in thrombosis was observed in all cases.
CONCLUSIONS: Endovascular treatment of aneurysms with MFM seems to have encouraging midterm results. Should our results be confirmed by larger series and longer follow-up studies, MFM may become a viable alternative to other endovascular approaches.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 26549808     DOI: 10.1016/j.avsg.2015.07.042

Source DB:  PubMed          Journal:  Ann Vasc Surg        ISSN: 0890-5096            Impact factor:   1.466


  5 in total

1.  Late surgical conversion of failed Multilayer Flow Modulator stenting in thoraco-abdominal aneurysms.

Authors:  Simone Salvati; Victor Bilman; Andrea Melloni; Domenico Baccellieri; Andrea Kahlberg; Germano Melissano; Roberto Chiesa; Luca Bertoglio
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-08-07

2.  Is endovascular treatment with multilayer flow modulator stent insertion a safe alternative to open surgery for high-risk patients with thoracoabdominal aortic aneurysm?

Authors:  Carolline Pinto; George Garas; Leanne Harling; Ara Darzi; Roberto Casula; Thanos Athanasiou
Journal:  Ann Med Surg (Lond)       Date:  2017-01-31

3.  The combined use of multilayer flow modulator stent and conventional stent grafts in complex thoracoabdominal aortic aneurysms and Type 3 dissections accompanying aneurysms.

Authors:  Cengiz Ovalı; Mustafa Behçet Sevin
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2018-04-30       Impact factor: 0.332

4.  A different approach to multilayer flow modulator implantation in aortic aneurysm.

Authors:  Cengiz Ovalı; Mustafa Behçet Sevin
Journal:  Anatol J Cardiol       Date:  2018-04-10       Impact factor: 1.596

5.  Treatment of Aortic and Iliac Artery Aneurysms with Multilayer Flow Modulator: Single Centre Experiences.

Authors:  Cengiz Ovalı; Aykut Şahin; Murat Eroğlu; Sinan Balçın; Sadettin Dernek; Mustafa Behçet Sevin
Journal:  Int J Vasc Med       Date:  2018-05-31
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.