Literature DB >> 26549067

Volume, conductivity, and scatter parameters as diagnostic aid to bacterial sepsis: A tertiary care experience.

Abhishek H L Purohit, Praveen Kumar, Subhadra Sharma, Arti Kapil, Ayush Gupta, Ashok K Mukhopadhyay1.   

Abstract

UNLABELLED: INTRODUCTION AND
MATERIALS AND METHODS: Early diagnosis of sepsis is extremely important to reduce high mortality and morbidity. In this study, clinical usefulness of the volume, conductivity and scatter parameters (mean channels of cell volume, conductivity, and light scatter) in neutrophils was analyzed for predicting acute bacterial infection, which are obtained by the Coulter LH 750 Hematology Analyzer (Beckman Coulter, Fullerton, CA, USA) during automated differential counts.
RESULTS: Peripheral blood samples from 162 patients with positive blood cultures for bacteria and 40 healthy controls were studied. We observed a significant increase in the mean channel of neutrophil volume (MNV) from septic patients compared with control subjects (156 ± 13.5 vs. 143 ± 4.8; P < 001). DISCUSSION AND
CONCLUSION: An elevation of the MNV was associated with a higher white blood cell count and percentage of neutrophils and was present even in patients who did not have leukocytosis or neutrophilia. With a cut-off of 149 for the MNV, a specificity of 91.4% and sensitivity of 88.7% were achieved. As a quantitative, objective, and more sensitive parameter, we propose that the MNV has a potential to be an additional indicator for acute bacterial infection.

Entities:  

Mesh:

Year:  2015        PMID: 26549067     DOI: 10.4103/0377-4929.168853

Source DB:  PubMed          Journal:  Indian J Pathol Microbiol        ISSN: 0377-4929            Impact factor:   0.740


  4 in total

1.  Utility of cell population data (VCS parameters) as a rapid screening tool for Acute Myeloid Leukemia (AML) in resource-constrained laboratories.

Authors:  Harpreet Virk; Neelam Varma; Shano Naseem; Ishwar Bihana; Dmitry Sukhachev
Journal:  J Clin Lab Anal       Date:  2018-09-29       Impact factor: 2.352

2.  Role of Automated Volume, Conductivity and Scatter (VCS) Parameters of Neutrophils as Indicators of Sepsis.

Authors:  Shruti Vaswani; Naveen Kakkar; Kanwardeep Singh Kwatra; Mary John
Journal:  Indian J Hematol Blood Transfus       Date:  2022-01-29       Impact factor: 0.915

3.  Automated hematology analyzers: Recent trends and applications.

Authors:  Gaurav Chhabra
Journal:  J Lab Physicians       Date:  2018 Jan-Mar

Review 4.  Sweet dreams: How mini-invasive surgery tackles obstructive sleep apnea.

Authors:  Sophia Julia Häfner
Journal:  Biomed J       Date:  2019-05-20       Impact factor: 4.910

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.