Literature DB >> 26547890

Multicenter clinical trial of high-intensity focused ultrasound treatment in glaucoma patients without previous filtering surgery.

Florent Aptel1, Philippe Denis2, Jean-François Rouland3, Jean-Paul Renard4, Alain Bron5.   

Abstract

PURPOSE: To evaluate the efficacy and safety of the ultrasonic circular cyclocoagulation procedure in patients with open-angle glaucoma naïve of previous filtering surgery.
METHODS: Prospective non-comparative interventional clinical study conducted in five French University Hospitals. Thirty eyes of 30 patients with open-angle glaucoma, intra-ocular pressure (IOP) > 21 mmHg and with no previous filtering glaucoma surgeries were sonicated with a probe comprising six piezoelectric transducers. The six transducers were activated with a 6-s exposure time. Complete ophthalmic examinations were performed before the procedure and at 1 day, 1 week, 1, 2, 3, 6 and 12 months after the procedure. Primary outcomes were qualified surgical success (defined as IOP reduction from baseline ≥20% and IOP > 5 mmHg with possible re-intervention and without hypotensive medication adjunction) and complete surgical success (defined as IOP reduction from baseline ≥20%, IOP > 5 mmHg and IOP < 21 mmHg with possible re-intervention and without hypotensive medication adjunction) at the last follow-up visit and vision-threatening complications. Secondary outcomes were mean IOP at each follow-up visit compared with baseline, medication use, complications and re-interventions.
RESULTS: Intra-ocular pressure was significantly reduced (p < 0.05) from a mean pre-operative value of 28.2 ± 7.2 mmHg (n = 3.6 hypotensive medications) to 19.6 ± 7.9 mmHg at 12 months (n = 3.1 hypotensive medications and n = 1.1 procedures) (mean IOP reduction of 30%). Qualified success was achieved in 63% of eyes (19/30) (mean IOP reduction of 37% in these eyes) and complete success in 46.7% of eyes (14/30) (mean IOP reduction of 37% in these eyes) at the last follow-up. No major intra- or post-operative complications occurred.
CONCLUSIONS: The UC(3) procedure seems to be an effective and well-tolerated method to reduce IOP in patients with open-angle glaucoma without previous filtering surgery.
© 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  ciliary body; cyclocoagulation; glaucoma; ultrasound

Mesh:

Substances:

Year:  2015        PMID: 26547890     DOI: 10.1111/aos.12913

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  16 in total

1.  Efficacy and safety of high-dose ultrasound cyclo-plasty procedure in refractory glaucoma.

Authors:  He-Ting Liu; Qing Zhang; Zheng-Xuan Jiang; Yu-Xin Xu; Qian-Qian Wan; Li-Ming Tao
Journal:  Int J Ophthalmol       Date:  2020-09-18       Impact factor: 1.779

2.  Ultrasound Cyclo Plasty in Eyes with Glaucoma.

Authors:  Giuseppe Giannaccare; Stefano Sebastiani; Emilio C Campos
Journal:  J Vis Exp       Date:  2018-01-26       Impact factor: 1.355

3.  High-intensity focused ultrasound treatment in patients with refractory glaucoma.

Authors:  Giuseppe Giannaccare; A Vagge; C Gizzi; A Bagnis; S Sebastiani; C Del Noce; M Fresina; C E Traverso; E C Campos
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-12-03       Impact factor: 3.117

4.  The Effect of High Intensity Focused Ultrasound Keratoplasty on Rabbit Anterior Segment.

Authors:  Menglei Wang; Meixuan Li; Pisong Yan; Qiang Luo; Yu Zhang; Zhiyu Du
Journal:  J Ophthalmol       Date:  2017-02-09       Impact factor: 1.909

Review 5.  Cyclodestructive Procedures in Glaucoma: A Review of Current and Emerging Options.

Authors:  Anna I Dastiridou; Andreas Katsanos; Philippe Denis; Brian A Francis; Dimitrios G Mikropoulos; Miguel A Teus; Anastasios-Georgios Konstas
Journal:  Adv Ther       Date:  2018-11-17       Impact factor: 3.845

6.  Short-Term Observation of Ultrasonic Cyclocoagulation in Chinese Patients with End-Stage Refractory Glaucoma: A Retrospective Study.

Authors:  Dongpeng Hu; Shu Tu; Chengguo Zuo; Jian Ge
Journal:  J Ophthalmol       Date:  2018-09-06       Impact factor: 1.909

7.  Pupil Ovalization and Accommodation Loss after High-intensity Focused Ultrasound Treatment for Glaucoma: A Case Report.

Authors:  Amado Rivero-Santana; David Pérez-Silguero; Miguel A Pérez-Silguero; Pablo Encinas-Pisa
Journal:  J Curr Glaucoma Pract       Date:  2019 May-Aug

Review 8.  High-Intensity Focused Ultrasound Circular Cyclocoagulation in Glaucoma: A Step Forward for Cyclodestruction?

Authors:  Rodolfo Mastropasqua; Vincenzo Fasanella; Alessandra Mastropasqua; Marco Ciancaglini; Luca Agnifili
Journal:  J Ophthalmol       Date:  2017-04-22       Impact factor: 1.909

9.  Application of high intensity focused ultrasound for treatment of open-angle glaucoma in Indian patients.

Authors:  Nilanjana Deb-Joardar; Kasu Prasad Reddy
Journal:  Indian J Ophthalmol       Date:  2018-04       Impact factor: 1.848

10.  High intensity focused ultrasound cyclocoagulation in dogs with primary glaucoma: a preliminary study.

Authors:  Pierre-François Isard; Marielle Mentek; David Clément; Aurélie Béglé; Fabrice Romano; Florent Aptel; Iona Mathieson; Thomas Dulaurent
Journal:  Open Vet J       Date:  2018-08-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.