Literature DB >> 26545864

Risk factors associated with early implant failure: A 5-year retrospective clinical study.

Maris Victoria Olmedo-Gaya1, Francisco J Manzano-Moreno2, Esther Cañaveral-Cavero3, Juan de Dios Luna-del Castillo4, Manuel Vallecillo-Capilla5.   

Abstract

STATEMENT OF PROBLEM: The replacement of lost teeth with dental implants is a widespread treatment whose associated problems are also frequently encountered. Nevertheless, the factors associated with early implant failure have not been well documented. Further analyses of the factors influencing osseointegration establishment are required to maximize the predictability of the procedure and minimize implant failures.
PURPOSE: The purpose of this retrospective clinical study was to explore the association between possible risk factors and early implant failure.
MATERIAL AND METHODS: This retrospective clinical study evaluated 142 participants who received 276 external connection BTI implants between 2007 and 2011. Participant variables (age, sex, systemic disease, tobacco use, alcohol consumption, bruxism, and degree of periodontal disease), implant variables (type of edentulism, localization, area, diameter, length, and bone quality), intervention variables (expansion mechanisms, sinus augmentation techniques, bone regeneration, and implant insertion), and postoperative variables (presence of pain/inflammation at 1 week postsurgery) were studied. A multilevel logistic regression model (mixed effects-type model) was used to determine the influence of variables on early implant failure.
RESULTS: Early implant failure was significantly associated with the male sex (P=.001), severe periodontal disease (P=.005), short implants (P=.001), expansion technique (P=.002), and postoperative pain/inflammation at 1 week postsurgery (P<.001).
CONCLUSIONS: Early dental implant failure is more frequent in men and in individuals with severe periodontal disease, short implants, pain/inflammation at 1 week postsurgery, or bone expansion treatment.
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26545864     DOI: 10.1016/j.prosdent.2015.07.020

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  16 in total

1.  Influence of 2D vs 3D imaging and professional experience on dental implant treatment planning.

Authors:  João Henrique Fortes; Christiano de Oliveira-Santos; Wilson Matsumoto; Raphael Jurca Gonçalves da Motta; Camila Tirapelli
Journal:  Clin Oral Investig       Date:  2018-06-16       Impact factor: 3.573

Review 2.  Do proton pump inhibitors affect the biomechanical efficiency of implant?- a systematic review.

Authors:  Varsha Verma
Journal:  J Oral Biol Craniofac Res       Date:  2022-08-17

3.  Cellular and Molecular Dynamics during Early Oral Osseointegration: A Comprehensive Characterization in the Lewis Rat.

Authors:  Sutton E Wheelis; Claudia C Biguetti; Shruti Natarajan; Alexandra Arteaga; Jihad El Allami; Bhuvana Lakkasettar Chandrashekar; Gustavo P Garlet; Danieli C Rodrigues
Journal:  ACS Biomater Sci Eng       Date:  2021-02-24

4.  Vitamin D deficiency in early implant failure: two case reports.

Authors:  Tobias Fretwurst; Sebastian Grunert; Johan P Woelber; Katja Nelson; Wiebke Semper-Hogg
Journal:  Int J Implant Dent       Date:  2016-11-25

5.  Biomimetic Implant Surface Functionalization with Liquid L-PRF Products: In Vitro Study.

Authors:  Marco Lollobrigida; Manuela Maritato; Giuseppina Bozzuto; Giuseppe Formisano; Agnese Molinari; Alberto De Biase
Journal:  Biomed Res Int       Date:  2018-05-08       Impact factor: 3.411

Review 6.  The impact of the alveolar bone sites on early implant failure: a systematic review with meta-analysis.

Authors:  Atef Abdel Hameed Fouda
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2020-06-30

7.  Satisfaction analysis of patients with single implant treatments based on a questionnaire survey.

Authors:  Heng Dong; Na Zhou; Hui Liu; Haohao Huang; Guangwen Yang; Li Chen; Meng Ding; Yongbin Mou
Journal:  Patient Prefer Adherence       Date:  2019-05-07       Impact factor: 2.711

8.  Proton pump inhibitor intake negatively affects the osseointegration of dental implants: a retrospective study.

Authors:  Mehmet Ali Altay; Alper Sindel; Öznur Özalp; Nelli Yıldırımyan; Burak Kocabalkan
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2019-06-28

Review 9.  Repeated failure of implants at the same site: a retrospective clinical study.

Authors:  Dong-Woo Kang; So-Hyun Kim; Yong-Hoon Choi; Young-Kyun Kim
Journal:  Maxillofac Plast Reconstr Surg       Date:  2019-07-10

10.  The Risk Factors in Early Failure of Dental Implants: a Retrospective Study.

Authors:  Hassan Mohajerani; Roozbeh Roozbayani; Shahram Taherian; Reza Tabrizi
Journal:  J Dent (Shiraz)       Date:  2017-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.