Hannah Jary1, Jamie Rylance2,3, Latifa Patel4, Stephen B Gordon5,6, Kevin Mortimer7,8.
Abstract
BACKGROUND: Air pollution is associated with a high burden or morbidity and mortality, but exposure cannot be quantified rapidly or cheaply. The particulate burden of macrophages from induced sputum may provide a biomarker. We compare the feasibility of two methods for digital quantification of airway macrophage particulate load.Entities:
Mesh:
Substances:
Year: 2015 PMID: 26542371 PMCID: PMC4635991 DOI: 10.1186/s12890-015-0135-7
Source DB: PubMed Journal: BMC Pulm Med ISSN: 1471-2466 Impact factor: 3.317
The exclusion criteria used for safety reasons prior to performing sputum induction
| Safety checklist – exclusion criteria for sputum induction |
|---|
| • FEV1 < 60 %/< 1.0 L (post – Salbutamol 200 micrograms) |
| • SaO2 < 90 % on room air |
| • Unable to take salbutamol |
| • Extreme shortness of breath |
| • Acute Respiratory Distress Syndrome |
| • Known haemoptysis |
| • Known arrhythmias/angina |
| • Known thoracic, abdominal or cerebral aneurysms |
| • Recent pneumothorax |
| • Pulmonary emboli |
| • Fractured ribs/recent chest trauma |
| • Recent eye surgery |
| • Known pleural effusions |
| • Pulmonary oedema |
Thrombocytopenia (Platelets < 25)
Fig. 1Systematic digital image acquisition. The pathway used to acquire digital images of cytospin ‘spots’ is shown
Fig. 2Image SXM and ImageJ methodology. Image SXM (a, b & c); digital images of the cytospins (a) were manually edited to remove all non-macrophage cells and debris (b). Image SXM then calculated the area of cytoplasm [27] and particulate matter (red), mapped out in the output image (c). ImageJ (d, e & f): for each macropghage, the threshold level was adjusted manually until the black areas of particulate matter seen in the original image (a) turned red (b). The particulate matter within the cytoplasm was then selected by freehand (c)
Fig. 3Participants and samples. The flow chart shows the number of consented and recruited patients, and how many samples were obtained and included in the final analysis
Characteristics of 13 participants
| Participant characteristic | ||
|---|---|---|
| Gender | Male, n (%) | 9 (69) |
| Female, n (%) | 4 (31) | |
| Age | Years, median (IQR) | 57 (39–67) |
| Respiratory diagnosis | Asthma, n (%) | 8 (62) |
| Bronchiectasis, n (%) | 2 (15) | |
| Both, n (%) | 3 (23) | |
| Smoking status | Never smoked (%) | 8 (62) |
| Ex-smoker (%) | 5 (38) | |
| Spirometry | FEV1, median (IQR), litres | 1.80 (1.47-2.26) |
| FEV1 % Predicted, median (IQR) | 73.5 (60.1 - 77.6) | |
| FVC, median (IQR), litres | 2.8 (2.47 – 3.82) | |
| FVC % predicted, median (IQR) | 91.2 (87.6 – 109.0) | |
IQR Interquartile Range
Differential cell counts
| Cell type | Cell count % (Median (IQR) of 13 participants) |
|---|---|
| Neutrophil | 72.5 (51.1-90.1) |
| Macrophage | 10.0 (4.1-25.8) |
| Eosinophil | 1.6 (1.0-8.5) |
| Lymphocyte | 2.3 (1.2-3.5) |
| Metachromatic | 0.0 (0.0-0.0) |
| Bronchial epithelial | 2.8 (1.1-12.6) |
| Squamous epithelial | 2.3 (0.8-6.5) |
Comparison of resource requirements for methods
| Resource | Image SXM | ImageJ |
|---|---|---|
| Equipment required for sputum induction and sample processing | Identical specialist equipment and facilities required regardless of analysis method | |
| Image acquisition equipment | Microscope with x40 objective and digital image capturing capabilities | Microscope with x100a objective and digital image capturing capabilities |
| Analysis software availability | In the public domain – available free of charge | In the public domain – available free of charge |
| Additional image editing software | Purchase required | Not required |
| Operating system for analysis software | Compatible with Mac operating systems | Compatible with Mac and Windows operating systems |
| File type availability | TIFF | JPEG, TIFF, GIF, BMP, DICOM, FITS and ‘raw’ |
| Time required for sputum induction and processing | Approximately 90–120 min per participant | |
| Time required for image acquisition (median) | 15 min | 27 min |
| Time required for image analysis (including image editing if required) (median) | 54 min | 26 min |
aAlthough a x100 objective is recommended for ImageJ methodology, a x60 objective was used in this study due to resource limitations
Fig. 4An example of inaccurte Image SXM analysis. Comparing the original image (a) to the output image (b), the total cellular area [27] of the airway macrophage on the left has been overestimated, and the partcilate matter (red) of the airway macrophage on the right has been overestimated
Fig. 5Airway macrophage heterogeneity. The morphology of the airway macrophages (shown with red arrows) was varied within the same sample (a) and between different participant samples (a & b). The particulate load also varied between macrophages in the same sample (a)