Literature DB >> 26541110

Rotational stability and patient satisfaction after implantation of a new toric IOL.

Balazs Gyöngyössy1, Paul Jirak2, Ulrich Schönherr1.   

Abstract

PURPOSE: To evaluate rotational stability, astigmatism correction, visual outcomes, and patient satisfaction after implantation of the toric intraocular lens (IOL) Torica-aA following cataract extraction over a 6-month follow-up period.
METHODS: This prospective observational study enrolled 40 eyes of 26 patients presenting with preexisting corneal astigmatism of 1.00 to 2.60 D. The rotational stability of the IOL was evaluated using retroillumination photographs taken within 24 hours after surgery and 1 week and 6 months postoperatively. Other main study outcomes were assessed 6 months postoperatively and included uncorrected and distance-corrected visual acuities, astigmatism correction, and patient satisfaction.
RESULTS: Six months postoperatively, mean absolute IOL rotation was 1.99 ± 1.88° (range 0.10-7.40°) and secondary repositioning was not required. The IOL rotation was <3° in 85% of eyes, ≤5° in 94% of eyes, and <8° in 100% of eyes. Mean residual refractive cylinder was -0.57 ± 0.34 D. The magnitude of the J0 vector was significantly decreased postoperatively (p<0.0001). The mean J45 vector was close to zero preoperatively and postoperatively (p = 0.27). Mean monocular uncorrected distance visual acuity (UDVA) was 0.09 ± 0.12 logMAR and 97% of eyes achieved UDVA of 20/40 or better including 66% of eyes having 20/25 or better. The good UDVA resulted in high levels of spectacle independence and patient satisfaction.
CONCLUSIONS: Implantation of the Torica-aA IOL was safe and effective in reducing low to moderate preexisting corneal astigmatism and provided good rotational stability and refractive outcomes, which led to a high degree of patient satisfaction.

Entities:  

Mesh:

Year:  2015        PMID: 26541110     DOI: 10.5301/ejo.5000696

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  2 in total

1.  Long-term rotational stability and visual outcomes of a single-piece hydrophilic acrylic toric IOL: a 1.5-year follow-up.

Authors:  Balázs Gyöngyössy; Paul Jirak; Ulrich Schönherr
Journal:  Int J Ophthalmol       Date:  2017-04-18       Impact factor: 1.779

2.  Patient-reported outcomes of multifocal and accommodating intraocular lenses: analysis of 117 patients 2-10 years after surgery.

Authors:  John A Hovanesian
Journal:  Clin Ophthalmol       Date:  2018-11-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.