Literature DB >> 26540683

A Prototype PZT Matrix Transducer With Low-Power Integrated Receive ASIC for 3-D Transesophageal Echocardiography.

Chao Chen, Shreyas B Raghunathan, Zili Yu, Maysam Shabanimotlagh, Zhao Chen, Zu-yao Chang, Sandra Blaak, Christian Prins, Jacco Ponte, Emile Noothout, Hendrik J Vos, Johan G Bosch, Martin D Verweij, Nico de Jong, Michiel A P Pertijs.   

Abstract

This paper presents the design, fabrication, and experimental evaluation of a prototype lead zirconium titanate (PZT) matrix transducer with an integrated receive ASIC, as a proof of concept for a miniature three-dimensional (3-D) transesophageal echocardiography (TEE) probe. It consists of an array of 9 ×12 piezoelectric elements mounted on the ASIC via an integration scheme that involves direct electrical connections between a bond-pad array on the ASIC and the transducer elements. The ASIC addresses the critical challenge of reducing cable count, and includes front-end amplifiers with adjustable gains and micro-beamformer circuits that locally process and combine echo signals received by the elements of each 3 ×3 subarray. Thus, an order-of-magnitude reduction in the number of receive channels is achieved. Dedicated circuit techniques are employed to meet the strict space and power constraints of TEE probes. The ASIC has been fabricated in a standard 0.18-μm CMOS process and consumes only 0.44 mW/channel. The prototype has been acoustically characterized in a water tank. The ASIC allows the array to be presteered across ±37° while achieving an overall dynamic range of 77 dB. Both the measured characteristics of the individual transducer elements and the performance of the ASIC are in good agreement with expectations, demonstrating the effectiveness of the proposed techniques.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26540683     DOI: 10.1109/TUFFC.2015.2496580

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  5 in total

Review 1.  Current Ultrasound Technologies and Instrumentation in the Assessment and Monitoring of COVID-19 Positive Patients.

Authors:  Xuejun Qian; Robert Wodnicki; Haochen Kang; Junhang Zhang; Hisham Tchelepi; Qifa Zhou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-08-28       Impact factor: 2.725

2.  On the Temperature Dependence of the Piezoelectric Response of Prepoled Poly(vinylidene fluoride) Films.

Authors:  Jeffrey D Sherman; Jeffrey Elloian; Jakub Jadwiszczak; Kenneth L Shepard
Journal:  ACS Appl Polym Mater       Date:  2020-08-27

3.  A reconfigurable all-optical ultrasound transducer array for 3D endoscopic imaging.

Authors:  Erwin J Alles; Nora Fook Sheung; Sacha Noimark; Edward Z Zhang; Paul C Beard; Adrien E Desjardins
Journal:  Sci Rep       Date:  2017-04-26       Impact factor: 4.379

4.  Sensitivity Enhanced Photoacoustic Imaging Using a High-Frequency PZT Transducer with an Integrated Front-End Amplifier.

Authors:  Chen Yang; Xiaohua Jian; Xinle Zhu; Jiabing Lv; Yang Jiao; Zhile Han; Antonios Stylogiannis; Vasilis Ntziachristos; George Sergiadis; Yaoyao Cui
Journal:  Sensors (Basel)       Date:  2020-01-30       Impact factor: 3.576

5.  Design of an Ultrasound Transceiver ASIC with a Switching-Artifact Reduction Technique for 3D Carotid Artery Imaging.

Authors:  Taehoon Kim; Fabian Fool; Djalma Simoes Dos Santos; Zu-Yao Chang; Emile Noothout; Hendrik J Vos; Johan G Bosch; Martin D Verweij; Nico de Jong; Michiel A P Pertijs
Journal:  Sensors (Basel)       Date:  2020-12-29       Impact factor: 3.576

  5 in total