Comparative characterization of a novel cad-cam polymer-infiltrated-ceramic-network.

Alberto Albero1, Agustín Pascual2, Isabel Camps3, María Grau-Benitez1.   

Abstract

BACKGROUND: The field of dental ceramics for CAD-CAM is enriched with a new innovative material composition having a porous three-dimensional structure of feldspathic ceramic infiltrated with acrylic resins.The aim of this study is to determine the mechanical properties of Polymer-Infiltrated-Ceramic-Network (PICN) and compare its performance with other ceramics and a nano-ceramic resin available for CAD-CAM systems.
MATERIAL AND METHODS: In this study a total of five different materials for CAD-CAM were investigated. A polymer-infiltrated ceramic (Vita Enamic), a nano-ceramic resin (Lava Ultimate), a feldspathic ceramic (Mark II), a lithium disilicate ceramic (IPS-e max CAD) and finally a Leucite based ceramic (Empress - CAD). From CAD-CAM blocks, 120 bars (30 for each material cited above) were cut to measure the flexural strength with a three-point-bending test. Strain at failure, fracture stress and Weibull modulus was calculated. Vickers hardness of each material was also measured.
RESULTS: IPS-EMAX presents mechanical properties significantly better from the other materials studied. Its strain at failure, flexural strength and hardness exhibited significantly higher values in comparison with the others. VITA ENAMIC and LAVA ULTIMATE stand out as the next most resistant materials.
CONCLUSIONS: The flexural strength, elastic modulus similar to a tooth as well as having less hardness than ceramics make PICN materials an option to consider as a restorative material. KEY WORDS: Ceramic infiltrated with resin, CAD-CAM, Weibull modulus, flexural strength, micro hardness.

Entities:  

Year:  2015        PMID: 26535096      PMCID: PMC4628804          DOI: 10.4317/jced.52521

Source DB:  PubMed          Journal:  J Clin Exp Dent        ISSN: 1989-5488


Introduction

One of the main objectives of restorative dentistry is to replace lost tooth structure with a material whose structure and physical properties are similar to a natural tooth (1). For this purpose, CAD-CAM technology is rapidly becoming popular, as it reduces the number of clinical sessions and manufacturing time of indirect restorations. Furthermore, the CAD-CAM system allows the use of new materials with improved properties compared with other materials used in direct restorative procedures (2). Ceramics, because of their chemical stability, have good mechanical and optical properties, as well as excellent biocompatibility. However, once placed in the mouth, repairs are often problematic if they are necessary. In contrast, the composites are easier to operate and repair but its wear, biocompatibility and mechanical properties are inferior to ceramic (3). Therefore, some authors suggest associating the elastic modulus of composites, which is similar to dentin, with feldspathic ceramic, similar to enamel, that would add long-term aesthetics, looking to make the ideal restorative material (4). With the intention of achieving this goal easily, a new material has recently been developed that attempts to emulate the properties of a natural tooth that is called polymers-infiltrated-ceramic-network (PICN) (1,3-9). PICN consist of two interlocking phases, a porous sinterized feldspathic ceramic and an infiltrating polymer (for dental use commonly methacrylates) (1). The aim of this study is to determine the mechanical properties of polymers-infiltrated-ceramic-network (PICN) and compare its behaviour with other materials available for CAD-CAM systems. For this purpose, flexural strength, fracture load, Vickers hardness and Weibull modulus were studied.

Material and Methods

In this study a total of five ceramic materials for CAD-CAM were investigated. Among them a polymer-infiltrated-ceramic-network (Enamic Vita, Vita Zahnfabrik, Bad Säckingen, Germany), a nano filled composite resin (Lava Ultimate, 3M ESPE, Neuss, Minn), a feldspathic ceramic (Mark II, Vita Zahnfabrik, Bad Säckingen, Germany), a lithium disilicate ceramic (IPS-e max CAD, Ivoclar Vivadent, Schaan, Liechtenstein) and finally, a Leucite based ceramic (Empress - CAD, Ivoclar Vivadent, Liechtenstein Schaab). 2.1 Flexural strength, fracture load and Weibull modulus From commercialized CAD-CAM blocks, 120 bending bars (n = 30) of each material (14 mm x 4 mm x 3 mm) (ISO 6872 (ISO 2009 [10])) were cut using a cutting machine (Struers Minitom, Willich, Germany ) at a rate of 250 rpm under water irrigation, to measure flexural strength in a three point bending test. IPS- e max CAD bars were crystallized in a ceramic furnace (Programat P300, Ivoclar Vivadent, Schaan Liechtenstein) following the manufacturer’s instructions and recommendations. Subsequently, the samples were polished with abrasive discs SiC paper 500, 1200 and 2400 # (LaboPol-1, Struers, Willich, Germany). All the bending bars were chamfered in order to minimize stress concentration due to machining flaws (ISO 6872 (ISO 2009 [10])). The bars were then subjected to an increasing load until fracture in a universal testing machine (Instron 4411, Massachusetts) in a three-point flexure with a crosshead speed of 0.5 mm / min. The fracture stress was calculated using the formula (1.6): (Fig. 1).
Figure 1

Fracture stress.

Fracture stress. Where F is the fracture load, L the roller span (12mm), w the width and h the height of the bar. The probability of fracture of different materials was studied using the Weibull cumulative distribution function. Values were analysed with the following formula: (Fig. 2).
Figure 2

Probability of fracture.

Probability of fracture. Where σ is the fracture stress, VE the effective volume, σ0 the characteristic strength (the strength occurring at a 63,2% probability of failure) and m the Weibull modulus. 2.2. Vickers hardness. For each material, twenty Vickers indentations were performed with loads of 50 N with a universal testing machine (HMV Shimadzu, Kyoto, Japan). The load was maintained for 20 seconds. The resultant diagonal of the indentation and the cracks derived from the diagonals were measured with a microscope. The hardness was calculated with the formula (1), (Fig. 3).
Figure 3

Hardness.

Hardness. Where F is the load and d is the indentation diagonal length. -Specifying statistical procedures used A general linear model (GLM) type ANOVA was estimated to compare homogeneity of average flexural strength in different materials (1,6). Levene’s test was used to test the homogeneity of variances, and if necessary, a Box-Cox transformation type is considered. Bonferroni multiple comparisons were employed to determine which pairs of materials exhibit similar average resistance with proper control of the statistical error of type I. The same GLM methodology was replicated to analyse strength and hardness. Models for the probability of fracture of the different ceramic materials using the Weibull cumulative distribution were estimated. The estimates are based on the Griffith formula for fragile materials and they consist of obtaining characteristic force values and Weibull modulus that best fit the experimental data. Graphical representations of the probability curve based on force were per-formed to allow comparison between ceramic types. Reference significance level is 5% (α = 0.05).

Results

3.1 Fracture load The fracture load is highest for IPS-EMAX, with an average of 0.44 ± 0.10 kN. VITA ENAMIC, LAVA ULTIMATE L, EMPRESS and MARKII have similar mean values to each other, and a lower level with a range from 0.22 to 0.26 kN. For example, for VITA-ENAMIC materials, 50% of the pieces were broken with a force between 0.22 and 0.26 kN approximately. Moreover, half of the pieces resisted less than 0.24 kN (median). There were two atypical cases with higher strengths than usual and one sample withstood extreme load, compared to their group ( Table 1).
Table 1

Fracture load, flexural strength and hardness of the different materials: Mean ± standard deviation. Groups with similar mean in one parameter according Bonferroni test share letter ( significance level 5%).

3.2 Flexural strength The maximum mean value of the resistance is recorded in the IPS-EMAX group (271.6 ± 64.7 Mpa), far ahead of VITA EN-AMIC, ULTIMATE LAVA, EMPRESS and MARKII, which are located at a second level, with a progressive decrease in resistance. VITA ENAMIC and LAVA ULTIMATE have similar resistance; but the latter is significantly less resistant than VITA ENAMIC (p = 0.008). At the same time, EMPRESS is comparable to MARKII; but the latter resists significantly less than LAVA ULTIMATE (p <0.001) ( Table 1, Fig. 4).
Figure 4

The mean and confidence intervals 95% are shown. As well as for loading, heterogeneity of variances (p < 0.001) was detected, so a Box- Cox Resistance - 1.27 transformation has been used for the analytical study.

The mean and confidence intervals 95% are shown. As well as for loading, heterogeneity of variances (p < 0.001) was detected, so a Box- Cox Resistance - 1.27 transformation has been used for the analytical study. The general linear model analysis of variance concluded that there are statistically significant differences (p <0.001) in mean values of the flexural strength of the different types of materials. Bonferroni tests allow the possibility to identify between which groups the differences are manifested ( Table 2).
Table 2

Bonferroni’s test allow to identify between wich groups the significant differences are given.

3.3 Hardness The average hardness is highest in the IPS-EMAX group (5.83 ± 0.07) followed by EMPRESS (4.60 ± 0.12) and MarkII (3.46 ± 0.15). At a substantially lower level are the values for VITA ENAMIC and LAVA ULTIMATE ( Table 1). It is evident that each material represents a very specific and heterogeneous hardness level, compared to any other (Fig. 5).
Figure 5

In this case, the equality of variances can be accepted from Levene test ( p> 0.05 ) and no exponential transformation is necessary.

In this case, the equality of variances can be accepted from Levene test ( p> 0.05 ) and no exponential transformation is necessary. The general linear model analysis of variance concluded that there are statistically significant differences (p <0.001) in mean hardness of the different types of materials. Bonferroni tests support the conclusion that each material has a significantly different hardness from the others ( Table 3).
Table 3

Bonferroni’s test for hardness. Can be seen that any material have significantly different hardness to any other.

3.4 Prediction of fracture probability (Weibull modulus) The probability function of fracture is estimated for each material. To do this, the Weibull modulus and characteristic stress of the materials studied were calculated ( Table 4). The greater the characteristic force, the more resistant the material is; and the higher the Weibull modulus, the greater the impact of force on fracture probability, which is the same when the force is increased a little, the stress rises considerably and fracture probability is triggered.
Table 4

Characteristic stress and Weibull modulus of studied materials.

The probability curve of IPS-EMAX is very different from the rest (Fig. 6). It is shifted to the right, that is a greater force is required to have the same probability of fracture than the other materials (noted in the table above that the characteristic force is higher). Moreover, a fixed stress increase moderately increases the likelihood of rupture, because the slope of the curve is moderately soft. It needs a force of between 150 MPa to 400 MPa to move over the entire range of possible values of probability (0-1).
Figure 6

Estimation of fracture probability.

Estimation of fracture probability. Of the other four materials, it is possible to distinguish two specific subgroups. Firstly, VITA and LAVA with more positive results in terms of resistance. Force characteristic (197 and 177 MPa) and weibull modulus (4.99 and 5.98) were estimated respectively. Secondly, EMPRESS and MARKII with lower characteristic force and very high modulus. That is, with little force the probability of failure is high and, moreover, it grows exponentially with small increases of force.

Discussion

The main objective of this work is to study the mechanical properties of the PICN and compare them to those of other commercialized materials for CAD-CAM. The materials were chosen to cover multiple restorative possibilities. Currently numerous articles speak of PICN (1,3-9) and mostly non-commercialized prototypes formed by different densities of feldspathic ceramic infiltrated with resin are used to study their mechanical properties and compare them with commercialized materials (1,3,6-9). Alvaro Della Bona (4) and MA Bottino (5) use a commercially available PICN (Vita Enamic, Vita Zahnfabrik). In the present study, a PICN is evaluated: Vita Enamic (Vita Zahnfabrik) in which, according to the manufacturer, 75% of its volume is feldspathic ceramic and 25% polymer; and a nano-ceramic resin Lava Ultimate (3M ESPE, Neuss) with 80% of ceramic nanoparticles, according to the manufacturer’s specifications. He and Swain (7,9) described the mechanical properties of these materials and found that they were very similar to natural dentin and enamel. This has been the aim throughout the years for restorative materials. The hardness and elastic modulus similar to those of the dental tissues values makes this material a good choice for restoring posterior areas with inlays (5). Furthermore, Ausiello P. (11) indicates that the elastic modulus of adhesive cements is very similar to the PICN value, allowing a more uniform distribution of stress during mastication in restored teeth. In PICN the density is closely related to the mechanical properties (7). Coldea Andrea (1) found that a minor fraction of the ceramic of PICN implies a lower elastic modulus and hardness, accompanied by an increase in flexural strength and failure load. In this same study (1), an increase in flexural strength of 9.2 to 28.8 MPa with increasing density is described. In turn, this also increases the elastic modulus from 3.30 to 54.5 GPa. PICN have a lower hardness than the rest of materials studied. ( Table 1). VITA ENAMIC hardness (1.70 ± 0.12 GPa) has a value substantially lower than the rest of the ceramics, corresponding to the IPS-EMAX (5.83 ± 0.7 GPa ) the maximum hardness value. This hardness value is closer to LAVA ULTIMATE (1.15 ± 0.13 GPa). The dentin hardness ranges from 0.6 to 0.92 GPa and enamel between 3-5.3 GPa (1) The lower hardness value presented by this material is considered as an advantage when it comes to protecting the opposing tooth from massive wear (1.7). Damage tolerance of the CIP is high when compared to other ceramics for CAD-CAM that usually breaks in mastication (6). He and Swain (7) found that the rate of fragility of the CIP had a value suitable for use in CAD-CAM. The extensions of the cracks coming out of the diagonals of the indentation were much longer in ceramics than in the CIP. The increased flexural strength of two phase materials compared to single phase, involves a reinforcement mechanism comparable to Travitzk et al., Prielipp et al., and Wegner et al. (12-14). In the last two studies, the porous ceramic was infiltrated by metal and their properties were analysed. The most common method used to characterize a ceramic resistance and structural reliability is the Weibull statistical theory (15), which describes the resistance of a brittle material based on the probability of survival with a given stress value, which is a function of volume under stress, the strength characteristics (a normalized parameter that corresponds with a stress level where 63% of the specimens fail) and the Weibull modulus, which indicates the nature, severity and spread of the defects. High Weibull modulus values correspond to materials with a very uniform distribution of a lot of homogeneous defects with a smaller strength distribution. Low Weibull modulus values correspond to materials with non-uniform distribution of defects with a highly variable crack length and a wide distribution of strength (16). For dental ceramics, the Weibull modulus values in the literature range from 5-15 (16). In the present study the figures ranged from 4.99 for VITA ENAMIC to 8.63 for EMPRESS (see Table 4). These values are similar to those presented by Carla Castiglia et al. (16) ranging from 5.2- to 11.7 for VM7 (Vita Zahnfabrik, Bad Säckingen, Germany) and D.Sign (Ivoclar Vivadent, Schaan, Liechtenstein) respectively. Although Empress and Mark II have lower resistance values, they have a greater Weibull modulus, which means that with less stress the probability of failure is high. This finding is important because in some situations, especially in areas of low stress, you can opt for a material with lower resistance but a higher Weibull modulus (16).

Conclusions

- IPS-EMAX exhibits significantly higher values in fracture load, flexural strength and hardness. The Weibull modulus emphasizes the previous conclusion. - VITA ENAMIC and LAVA ULTIMATE stand out as being the second most resistant materials, after IPS- EMAX. The hardness of these materials is significantly lower than ceramics. - The flexural strength, the elastic modulus similar to the tooth and lower hardness of these materials make PICN an option to be considered as filling material.
  12 in total

1.  Slow crack growth and reliability of dental ceramics.

Authors:  Carla Castiglia Gonzaga; Paulo Francisco Cesar; Walter Gomes Miranda; Humberto Naoyuki Yoshimura
Journal:  Dent Mater       Date:  2010-12-24       Impact factor: 5.304

2.  A novel polymer infiltrated ceramic for dental simulation.

Authors:  Li-Hong He; David Purton; Michael Swain
Journal:  J Mater Sci Mater Med       Date:  2011-05-26       Impact factor: 3.896

3.  Inlays made from a hybrid material: adaptation and bond strengths.

Authors:  M A Bottino; F Campos; N C Ramos; M P Rippe; L F Valandro; R M Melo
Journal:  Oper Dent       Date:  2014-11-18       Impact factor: 2.440

4.  Fabrication and characterization of biomimetic ceramic/polymer composite materials for dental restoration.

Authors:  Morena Petrini; Maurizio Ferrante; Bo Su
Journal:  Dent Mater       Date:  2013-01-08       Impact factor: 5.304

5.  Mechanical properties of polymer-infiltrated-ceramic-network materials.

Authors:  Andrea Coldea; Michael V Swain; Norbert Thiel
Journal:  Dent Mater       Date:  2013-02-12       Impact factor: 5.304

6.  In-vitro strength degradation of dental ceramics and novel PICN material by sharp indentation.

Authors:  Andrea Coldea; Michael V Swain; Norbert Thiel
Journal:  J Mech Behav Biomed Mater       Date:  2013-05-15

7.  A novel polymer infiltrated ceramic dental material.

Authors:  Li-Hong He; Michael Swain
Journal:  Dent Mater       Date:  2011-03-02       Impact factor: 5.304

8.  Characterization of a polymer-infiltrated ceramic-network material.

Authors:  Alvaro Della Bona; Pedro H Corazza; Yu Zhang
Journal:  Dent Mater       Date:  2014-03-20       Impact factor: 5.304

Review 9.  A practical and systematic review of Weibull statistics for reporting strengths of dental materials.

Authors:  Janet B Quinn; George D Quinn
Journal:  Dent Mater       Date:  2009-11-28       Impact factor: 5.304

10.  High-temperature-pressure polymerized resin-infiltrated ceramic networks.

Authors:  J F Nguyen; D Ruse; A C Phan; M J Sadoun
Journal:  J Dent Res       Date:  2013-11-01       Impact factor: 6.116

View more
  15 in total

1.  Publication trends in journal of clinical and experimental dentistry.

Authors:  Vidhi-Kiran Bhalla; Sherin-Jose Chockattu
Journal:  J Clin Exp Dent       Date:  2020-09-01

2.  The residual monomer content and mechanical properties of CAD\CAM resins used in the fabrication of complete dentures as compared to heat cured resins.

Authors:  Al-Dharrab Ayman
Journal:  Electron Physician       Date:  2017-07-25

3.  In Vitro Comparative Analysis of Fracture Resistance in Inlay Restoration Prepared with CAD-CAM and Different Systems in the Primary Teeth.

Authors:  Huseyin Simsek; Sera Derelioglu
Journal:  Biomed Res Int       Date:  2016-10-17       Impact factor: 3.411

4.  Evaluation of five CAD/CAM materials by microstructural characterization and mechanical tests: a comparative in vitro study.

Authors:  Nesrin Sonmez; Pinar Gultekin; Volkan Turp; Gokhan Akgungor; Deniz Sen; Eitan Mijiritsky
Journal:  BMC Oral Health       Date:  2018-01-08       Impact factor: 2.757

5.  Effect of professional dental prophylaxis on the surface gloss and roughness of CAD/CAM restorative materials.

Authors:  Toshiko Sugiyama; Atsushi Kameyama; Tomoka Enokuchi; Akiko Haruyama; Aoi Chiba; Setsuko Sugiyama; Makoto Hosaka; Toshiyuki Takahashi
Journal:  J Clin Exp Dent       Date:  2017-06-01

6.  Biomechanical properties of polymer-infiltrated ceramic crowns on one-piece zirconia implants after long-term chewing simulation.

Authors:  Pia Baumgart; Holger Kirsten; Rainer Haak; Constanze Olms
Journal:  Int J Implant Dent       Date:  2018-05-23

7.  Mechanical properties and DIC analyses of CAD/CAM materials.

Authors:  Thiago Porto; Renato Roperto; Anna Akkus; Ozan Akkus; Sizenando Porto-Neto; Sorin Teich; Lisa Lang; Edson Campos
Journal:  J Clin Exp Dent       Date:  2016-12-01

8.  Effect of Endocrown Restorations with Different CAD/CAM Materials: 3D Finite Element and Weibull Analyses.

Authors:  Laden Gulec; Nuran Ulusoy
Journal:  Biomed Res Int       Date:  2017-09-28       Impact factor: 3.411

9.  A Comparative Study on the Mechanical Properties of a Polymer-Infiltrated Ceramic-Network Material Used for the Fabrication of Hybrid Abutment.

Authors:  Salim Ongun; Sevcan Kurtulmus-Yilmaz; Gökçe Meriç; Mutahhar Ulusoy
Journal:  Materials (Basel)       Date:  2018-09-11       Impact factor: 3.623

10.  Effect of surface treatments on the bond strength of indirect resin composite to resin matrix ceramics.

Authors:  Ersan Çelik; Sezgi Cinel Şahin; Doğu Ömür Dede
Journal:  J Adv Prosthodont       Date:  2019-08-27       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.