Literature DB >> 2653086

Clinical comparison of inhaled budesonide delivered either via pressurized metered dose inhaler or Turbuhaler.

T Engel1, J H Heinig, H J Malling, B Scharling, K Nikander, F Madsen.   

Abstract

The aim of this open, randomized cross-over study was to compare the efficacy and safety of inhaled budesonide administered either via a pressurized metered dose inhaler with a 750 ml spacer attached, or via a new dry powder inhaler, Turbuhaler, in 28 patients with stable bronchial asthma. During the 2-week run-in period, the patients received their ordinary inhaled steroid treatment. This was followed by two 4-week periods of active treatment with inhaled budesonide given via Turbuhaler or pressurized MDI. The patients were divided into two groups according to their previous, inhaled steroid doses. Group A received 400 micrograms of budesonide b.i.d, and Group B 800 micrograms of budesonide b.i.d. Diary cards were used by the patients at home to report asthma symptoms, beta 2-agonist consumption, and PEF twice daily, as well as the number of coughs experienced in a 5-min period after steroid inhalation. Budesonide Turbuhaler produced a significantly better effect on morning peak flow than budesonide MDI. The number of coughs in the 5 min after steroid inhalation was significantly lower with the Turbuhaler than with the MDI. In all other parameters recorded (e.g. FEV1, evening PEF, histamine PC20 and other diary measurements) there were no statistically significant differences between the two devices. Turbuhaler was significantly more appreciated than MDI in all questions of preference. The study showed that budesonide via Turbuhaler was at least as effective and safe as budesonide via a pressurized MDI at daily doses of 800 and 1,600 micrograms.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2653086     DOI: 10.1111/j.1398-9995.1989.tb02266.x

Source DB:  PubMed          Journal:  Allergy        ISSN: 0105-4538            Impact factor:   13.146


  18 in total

1.  Systematic review of clinical effectiveness of pressurised metered dose inhalers versus other hand held inhaler devices for delivering corticosteroids in asthma.

Authors:  D Brocklebank; J Wright; C Cates
Journal:  BMJ       Date:  2001-10-20

Review 2.  Inhaler devices for the treatment of asthma and chronic obstructive airways disease (COPD).

Authors:  J Wright; D Brocklebank; F Ram
Journal:  Qual Saf Health Care       Date:  2002-12

3.  General practitioners and asthma.

Authors:  P W Barritt
Journal:  Thorax       Date:  1992-09       Impact factor: 9.139

Review 4.  Deposition and effects of inhaled corticosteroids.

Authors:  Stephen P Newman
Journal:  Clin Pharmacokinet       Date:  2003       Impact factor: 6.447

5.  Effects, side effects and plasma concentrations of terbutaline in adult asthmatics after inhaling from a dry powder inhaler device at different inhalation flows and volumes.

Authors:  T Engel; B Scharling; B Skovsted; J H Heinig
Journal:  Br J Clin Pharmacol       Date:  1992-04       Impact factor: 4.335

6.  The influence of orally deposited budesonide on the systemic availability of budesonide after inhalation from a Turbuhaler.

Authors:  S Pedersen; G Steffensen; S V Ohlsson
Journal:  Br J Clin Pharmacol       Date:  1993-09       Impact factor: 4.335

Review 7.  Cough as an adverse effect on inhalation pharmaceutical products.

Authors:  Rachel Yoon Kyung Chang; Philip Chi Lip Kwok; Sussan Ghassabian; John D Brannan; Heikki O Koskela; Hak-Kim Chan
Journal:  Br J Pharmacol       Date:  2020-08-07       Impact factor: 8.739

Review 8.  Antiasthma drug delivery. What is on the horizon?

Authors:  J C Virchow; C Kroegel; H Matthys
Journal:  Clin Pharmacokinet       Date:  1994-08       Impact factor: 6.447

9.  Large volume spacer devices and the influence of high dose beclomethasone dipropionate on hypothalamo-pituitary-adrenal axis function.

Authors:  P H Brown; A P Greening; G K Crompton
Journal:  Thorax       Date:  1993-03       Impact factor: 9.139

10.  Importance of the inhalation device on the effect of budesonide.

Authors:  L Agertoft; S Pedersen
Journal:  Arch Dis Child       Date:  1993-07       Impact factor: 3.791

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.