(13) C Breath Tests Are Feasible in Patients With Extracorporeal Membrane Oxygenation Devices.

Jan Bednarsch1,2, Mario Menk3, Maciej Malinowski1, Steffen Weber-Carstens3, Johann Pratschke1, Martin Stockmann1.   

Abstract

Temporary extracorporeal membrane oxygenation (ECMO) has been established as an essential part of therapy in patients with pulmonary or cardiac failure. As physiological gaseous exchange is artificially altered in this patient group, it is debatable whether a (13) C-breath test can be carried out. In this proof of technical feasibility report, we assess the viability of the (13) C-breath test LiMAx (maximum liver function capacity) in patients on ECMO therapy. All breath probes for the test device were obtained directly via the membrane oxygenator. Data of four patients receiving liver function assessment with the (13) C-breath test LiMAx while having ECMO therapy were analyzed. All results were compared with validated scenarios of the testing procedures. The LiMAx test could successfully be carried out in every case without changing ECMO settings. Clinical course of the patients ranging from multiorgan failure to no sign of liver insufficiency was in accordance with the results of the LiMAx liver function test. The (13) C-breath test is technically feasible in the context of ECMO. Further evaluation of (13) C-breath test in general would be worthwhile. The LiMAx test as a (13) C-breath test accessing liver function might be of particular predictive interest if patients with ECMO therapy develop multiorgan failure.
Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Keywords:  Breath tests; Carbon isotopes; Extracorporeal assist; Extracorporeal membrane oxygenation; Liver function; Maximum liver function capacity; Methacetin

Mesh:

Substances:

Year:  2015        PMID: 26527580     DOI: 10.1111/aor.12634

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  3 in total

Review 1.  13C Methacetin Breath Test for Assessment of Microsomal Liver Function: Methodology and Clinical Application.

Authors:  Katarzyna Gorowska-Kowolik; Agata Chobot; Jaroslaw Kwiecien
Journal:  Gastroenterol Res Pract       Date:  2017-07-05       Impact factor: 2.260

2.  Enzymatic liver function measured by LiMAx - a reliable diagnostic and prognostic tool in chronic liver disease.

Authors:  Matthias Buechter; Sarah Kersting; Guido Gerken; Alisan Kahraman
Journal:  Sci Rep       Date:  2019-09-19       Impact factor: 4.379

3.  A proof of concept study on real-time LiMAx CYP1A2 liver function assessment of donor grafts during normothermic machine perfusion.

Authors:  Ivo J Schurink; Jubi E de Haan; Jorke Willemse; Matteo Mueller; Michael Doukas; Henk Roest; Femke H C de Goeij; Wojciech G Polak; Jan N M Ijzermans; Philipp Dutkowski; Luc J W van der Laan; Jeroen de Jonge
Journal:  Sci Rep       Date:  2021-12-06       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.