Biomechanical Effect of Thickness and Tension of Fascia Lata Graft on Glenohumeral Stability for Superior Capsule Reconstruction in Irreparable Supraspinatus Tears.

Teruhisa Mihata1, Michelle H McGarry2, Timothy Kahn2, Iliya Goldberg2, Masashi Neo3, Thay Q Lee3.   

Abstract

PURPOSE: To investigate the effects of graft length and thickness on shoulder biomechanics after superior capsule reconstruction.
METHODS: Subacromial peak contact pressure and glenohumeral superior translation were measured at 0°, 30°, and 60° of glenohumeral abduction in 8 fresh-frozen cadaveric shoulders under 5 conditions: (1) intact shoulder; (2) irreparable supraspinatus tendon tear, (3) superior capsule reconstruction with a fascia lata allograft 4-mm thick and 15 mm longer than the distance from the superior glenoid to the lateral edge of the greater tuberosity, as determined during placement at 30° of glenohumeral abduction; (4) superior capsule reconstruction with a fascia lata allograft 8-mm thick and with the same 15 mm relative length determined at 10° of glenohumeral abduction, and (5) superior capsule reconstruction with a fascia lata allograft 8-mm thick and with the 15-mm relative length determined at 30° of glenohumeral abduction. To investigate the effect of graft thickness, we compared the data from conditions 1, 2, 3, and 5. To assess the effect of graft length, we compared conditions 1, 2, 4, and 5.
RESULTS: With superior capsule reconstruction using a 4-mm graft, subacromial peak contact pressure (but not superior translation) was significantly lower than with irreparable supraspinatus tears (at 0° abduction: 259% decrease; P = .0002; at 30° abduction: 113% decrease; P = .01). The superior capsule reconstruction using an 8-mm graft significantly decreased both subacromial peak contact pressure (at 0° abduction: 246% decrease, P = .0002; at 30° abduction: 158% decrease; P = .0008; at 60° abduction: 57% decrease; P = .04) and superior translation (at 0° abduction: 135% decrease; P = .02; at 30° abduction; 130% decrease; P = .004). Graft length with placement at 10° glenohumeral abduction was 5 mm greater than that at 30° abduction. The 8-mm superior capsule reconstruction performed at 10° or 30° of glenohumeral abduction significantly decreased subacromial peak contact pressure (placement at 10° and 30°: 0° abduction, P = .0002 and .0002, respectively; 30° abduction, P = .0004 and .0005, respectively; 60° abduction, P = .04 and .04, respectively) and superior translation (placement at 10° and 30°; 0° abduction, P =.04 and .02, respectively; 30° abduction, P = .02 and .004, respectively) compared with irreparable supraspinatus tears.
CONCLUSIONS: Superior capsule reconstruction normalized the superior stability of the shoulder joint when the graft was attached at 10° or 30° of glenohumeral abduction. An 8-mm-thick graft of fascia lata had greater stability than did a 4-mm-thick graft. CLINICAL RELEVANCE: Grafts 8-mm thick and attached at 15° to 45° of shoulder abduction (equal to 10° to 30° of glenohumeral abduction) biomechanically restore shoulder stability during superior capsule reconstruction using fascia lata.
Copyright © 2016 Arthroscopy Association of North America. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 26524937     DOI: 10.1016/j.arthro.2015.08.024

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  44 in total

1.  The "Pull-Over" Technique for Arthroscopic Superior Capsular Reconstruction.

Authors:  A Ali Narvani; Paolo Consigliere; Ioannis Polyzois; Tanaya Sarkhel; Rohit Gupta; Ofer Levy
Journal:  Arthrosc Tech       Date:  2016-12-19

2.  Arthroscopic Superior Capsular Reconstruction for Massive Irreparable Rotator Cuff Repair.

Authors:  Stephen S Burkhart; Patrick J Denard; Christopher R Adams; Paul C Brady; Robert U Hartzler
Journal:  Arthrosc Tech       Date:  2016-12-12

Review 3.  How to Use a Graft in Irreparable Rotator Cuff Tears: A Literature Review Update of Interposition and Superior Capsule Reconstruction Techniques.

Authors:  Kevin C Wall; Alison P Toth; Grant E Garrigues
Journal:  Curr Rev Musculoskelet Med       Date:  2018-03

4.  Can inadequate acromiohumeral distance improvement and poor posterior remnant tissue be the predictive factors of re-tear? Preliminary outcomes of arthroscopic superior capsular reconstruction.

Authors:  Seung-Jun Lee; Young-Kyoung Min
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-03-28       Impact factor: 4.342

5.  Case study: failure of superior capsular reconstruction using dermal allograft.

Authors:  J Zerr; J D McDermott; N M Beckmann; R K Fullick; A Chhabra
Journal:  Skeletal Radiol       Date:  2017-07-26       Impact factor: 2.199

6.  Effect of human dermal allograft thickness on glenohumeral stability for superior capsular reconstruction in irreparable supraspinatus tears: A biomechanical analysis of the superior capsular reconstruction - A cadaveric study.

Authors:  Geoffrey Cs Smith; Heon Y Im; Patrick H Lam
Journal:  Shoulder Elbow       Date:  2020-05-25

7.  Biceps-incorporating rotator cuff repair with footprint medialization in large-to-massive rotator cuff tears.

Authors:  Jin Hwa Jeong; Eun Ji Yoon; Bo Seoung Kim; Jong-Hun Ji
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-01-06       Impact factor: 4.342

8.  An in-vitro biomechanical assessment of humeral head migration following irreparable rotator cuff tear and subacromial balloon reconstruction.

Authors:  Jacob M Reeves; Supriya Singh; G Daniel G Langohr; George S Athwal; James A Johnson
Journal:  Shoulder Elbow       Date:  2019-08-05

Review 9.  [Research progress of indication and treatment of graft in shoulder superior capsular reconstruction for rotator cuff tear].

Authors:  Huaisheng Li; Mingyu Yang; Yan Li; Binghua Zhou; Kanglai Tang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-02-15

10.  Proximal and mid-thigh fascia lata graft constructs used for arthroscopic superior capsule reconstruction show equivalent biomechanical properties: an in vitro human cadaver study.

Authors:  Clara Isabel de Campos Azevedo; Ana Catarina Leiria Pires Gago Ângelo; Carlos Quental; Sérgio Gonçalves; João Folgado; Nuno Ferreira; Nuno Sevivas
Journal:  JSES Int       Date:  2021-03-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.