Literature DB >> 26522626

Efficacy and Safety of Transthoracic Echocardiography Alone in Transcatheter Closure of Secundum-Type Atrial Septal Defects in Adults.

Cheng Ding1, Jia-Kan Chang2, Chang-Chyi Lin3, Yong-Jian Wu1, Kai-Sheng Hsieh4.   

Abstract

BACKGROUND: On-site transthoracic echocardiography (TTE) to guide the transcutaneous closure of secundum-type atrial septal defects (ASDs) in the catheterization laboratory remains unclear, especially in adults.
METHODS: Between 2005 and 2012, a total of 82 adults underwent transcutaneous closure of ASDs. The initial 15 cases underwent the procedure with both on-site transesophageal echocardiography (TEE) and TTE monitoring. Since January 2008, a total of 67 patients underwent on-site TTE alone to guide the procedure.
RESULTS: Among the 82 adult patients who underwent a transcutaneous closure of the secundum-type ASD procedure, all had successful closure of the defects, and no periprocedural adverse complications occurred. No statistical significance was observed in the successful complete shunt closure rate between the TEE plus TTE and TTE groups during sequential follow-up (postprocedure 24 hour [87% vs. 92%],1 month [93% vs. 95%], 3 month [93% vs. 97%], and 12 month [93% vs. 97%], P > 0.05, respectively) nor was a significant difference observed between the two groups, including decreased right ventricular dimension (29.5 ± 3.3 vs. 32.0 ± 4.9 mm, 26.5 ± 3.0 vs. 28.7 ± 4.6 mm, 26.2 ± 3.1 vs. 28.2 ± 4.8 mm, and 25.6 ± 2.8 vs. 27.7 ± 4.7 mm, P > 0.05, respectively) or increased left ventricular end-diastolic dimension (41.1 ± 2.0 vs. 42.6 ± 3.0 mm, 44.3 ± 2.7 vs. 45.5 ± 3.1 mm, 44.2 ± 2.8 vs. 45.4 ± 3.1 mm, 44.9 ± 2.7 vs. 45.8 ± 2.6 mm, P > 0.05, respectively) before the procedure, and at the 3-, 6-, and 12-month follow-up evaluations.
CONCLUSION: This study showed that TTE guidance alone may be considered efficacious and safe as TEE during a transcutaneous ASD occlusion procedure in select adults.
© 2015, Wiley Periodicals, Inc.

Entities:  

Keywords:  interventional cardiac catheterization; percutaneous transcatheter closure; transthoracic echocardiography

Mesh:

Year:  2015        PMID: 26522626     DOI: 10.1111/echo.13106

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  4 in total

1.  Safety and efficacy of transthoracic versus transesophageal echocardiography in transcatheter closure of atrial septal defects. Reporting a single center experience from Saudi Arabia.

Authors:  Ahmad S Azhar
Journal:  Saudi Med J       Date:  2016-11       Impact factor: 1.484

2.  Comparative study of the transcatheter and transthoracic device closure treatments for atrial septal defect: A Chinese single-institution experience.

Authors:  Qiang Chen; Hua Cao; Zhao-Yang Chen; Gui-Can Zhang; Liang-Wan Chen; Fan Xu; Jia-Jun He
Journal:  Medicine (Baltimore)       Date:  2017-03       Impact factor: 1.889

3.  Transcatheter device closure of atrial septal defects guided completely by transthoracic echocardiography: A single cardiac center experience with 152 cases.

Authors:  Qiang Chen; Hua Cao; Gui Can Zhang; Liang Wan Chen; Heng Lu; Lin Li Yu
Journal:  Anatol J Cardiol       Date:  2018-12       Impact factor: 1.596

4.  Comparison of the efficacy and safety of sedation protocols with the use of dexmedetomidine-remifentanil and propofol-remifentanil during percutaneous closure of atrial septal defects: a randomized clinical trial.

Authors:  Xiao-Lan Chen; Wen-Hui Huang; Yi-Han Zheng; Gui-Can Zhang
Journal:  J Cardiothorac Surg       Date:  2022-05-03       Impact factor: 1.522

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.