Literature DB >> 26520383

High-throughput sample processing and sample management; the functional evolution of classical cytogenetic assay towards automation.

Adarsh Ramakumar1, Uma Subramanian2, Pataje G S Prasanna2.   

Abstract

High-throughput individual diagnostic dose assessment is essential for medical management of radiation-exposed subjects after a mass casualty. Cytogenetic assays such as the Dicentric Chromosome Assay (DCA) are recognized as the gold standard by international regulatory authorities. DCA is a multi-step and multi-day bioassay. DCA, as described in the IAEA manual, can be used to assess dose up to 4-6 weeks post-exposure quite accurately but throughput is still a major issue and automation is very essential. The throughput is limited, both in terms of sample preparation as well as analysis of chromosome aberrations. Thus, there is a need to design and develop novel solutions that could utilize extensive laboratory automation for sample preparation, and bioinformatics approaches for chromosome-aberration analysis to overcome throughput issues. We have transitioned the bench-based cytogenetic DCA to a coherent process performing high-throughput automated biodosimetry for individual dose assessment ensuring quality control (QC) and quality assurance (QA) aspects in accordance with international harmonized protocols. A Laboratory Information Management System (LIMS) is designed, implemented and adapted to manage increased sample processing capacity, develop and maintain standard operating procedures (SOP) for robotic instruments, avoid data transcription errors during processing, and automate analysis of chromosome-aberrations using an image analysis platform. Our efforts described in this paper intend to bridge the current technological gaps and enhance the potential application of DCA for a dose-based stratification of subjects following a mass casualty. This paper describes one such potential integrated automated laboratory system and functional evolution of the classical DCA towards increasing critically needed throughput. Published by Elsevier B.V.

Entities:  

Keywords:  Automation; Biodosimetry; Cytogenetic laboratory; Dicentric assay; Laboratory information system; Radiation exposure assessment; Radiation mass casualty triage

Mesh:

Year:  2015        PMID: 26520383     DOI: 10.1016/j.mrgentox.2015.07.011

Source DB:  PubMed          Journal:  Mutat Res Genet Toxicol Environ Mutagen        ISSN: 1383-5718            Impact factor:   2.873


  1 in total

1.  Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation.

Authors:  Ben Shirley; Yanxin Li; Joan H M Knoll; Peter K Rogan
Journal:  J Vis Exp       Date:  2017-09-04       Impact factor: 1.355

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.