| Literature DB >> 26516864 |
Haiyun Huang1,2, Dejun Wang3, Yue Xu4.
Abstract
This paper presents a fully integrated linear Hall sensor by means of 0.8 μm high voltage complementary metal-oxide semiconductor (CMOS) technology. This monolithic Hall sensor chip features a highly sensitive horizontal sEntities:
Keywords: Hall offset; dynamic offset cancellation technique; monolithic Hall sensor; sensitivity and linearity
Year: 2015 PMID: 26516864 PMCID: PMC4634499 DOI: 10.3390/s151027359
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Figure 1Cross-like Hall plate. (a) Conventional short contact structure; (b) Long contact structure.
Figure 2Offset voltage comparison of long-contact and short-contact Hall plates.
Figure 3Magnetic sensitivity comparison of long-finger and optimized Hall plates. (a) S; (b) S.
Figure 4Block diagram of CMOS integrated linear Hall sensor microsystem.
Figure 5Circuit diagram of spinning current modulator of Hall sensor.
Figure 6Instrumentation amplifier.
Figure 7Demodulation circuit with sample/hold and adding functions.
Figure 8Transient output waveform of spinning current modulator of horizontal Hall sensor.
Figure 9Transient output waveform of low-pass filter of the linear Hall sensor microsystem.
Figure 10Micrograph of CMOS monolithic integrated Hall magnetic sensor.
Figure 11Tested magnetic sensitivity of cross-like Hall plate versus bias voltage or current. (a) S; (b) S.
Figure 12Tested offset voltage of cross-like Hall plate versus bias voltage.
Figure 13Hall output voltage of the integrated Hall sensor versus magnetic flux density.
Figure 14Transient output waveform of the integrated Hall sensor for a 1 kHz 170 mT sinusoidal magnetic flux density.
Performance summary and comparison of CMOS monolithic integrated Hall sensors.
| Parameters | Reference[ | Reference[ | This Work |
|---|---|---|---|
| Technology | 2 μm BiCMOS | 0.8 μm CMOS | 0.8 μm HV CMOS |
| Supply voltage | 5 V | 5 V | 5 V |
| Static power consumption | 35 mW | N/A | 20 mW |
| Quiescent working point | 2.5 V | N/A | 2.5 V |
| Measurement range | ±100 mT | ±50 mT | ±175 mT |
| Equivalent residual offset | 0.5 mT | N/A | 0.48 mT |
| linearity | 99.9% | >99% | >99% |