Literature DB >> 26511397

Focal impulse and rotor modulation using the novel 64-electrode basket catheter: electrogram characteristics of human rotors.

Tina Lin1, Andreas Rillig2, Tudor Bucur2, Andreas Metzner2, Shibu Mathew2, Erik Wissner2, Peter Wohlmuth3, Karl-Heinz Kuck2, Feifan Ouyang2, Roland Richard Tilz2.   

Abstract

AIMS: Ablation of fractionated electrograms (EGMs) has been performed to eliminate areas of slow conduction in atrial fibrillation (AF). The rotor hypothesis suggests that rapidly activating spiral waves perpetuate and maintain AF. This study describes the EGM characteristics of AF rotors, using the novel 64-electrode basket catheter. METHODS AND
RESULTS: Twenty-five patients (male n = 16) with AF (paroxysmal n = 10) underwent focal impulse and rotor modulation. A 3.5 mm irrigated-tip ablation catheter was placed at the identified rotor core and EGMs were analysed for amplitude, characteristics (single-EGM, fractionated-EGM, and continuous-EGM), and cycle length over 10 s. A total of 72 rotors were identified [right atrium (RA) = 13, left atrium (LA) = 59]. Seven rotors were excluded from EGM analysis due to location in the pulmonary veins. Single-EGMs were more frequent in the RA compared with the LA (8 (61.5) vs. 12 (23.1); P < 0.01) and EGM amplitudes were smaller in LA rotors when compared with RA rotors (0.14 (0.08-0.17) mV vs. 0.19 (0.15-0.29) mV; P = 0.029). In patients with persistent AF, single-EGMs were observed more often in the right-sided rotors compared with left-sided rotors (4 (57.1) vs. 5 (14.3); P = 0.012), and EGM amplitudes were smaller in patients with persistent AF compared with paroxysmal atrial fibrillation (PAF) patients (0.15 (0.09-0.19) mV vs. 0.22 (0.17-0.47) mV; P = 0.03). Furthermore, the prevalence of fractionated- EGMs was higher in patients with persistent AF compared with PAF patients (31/42 (73.8) vs. 9/23 (39.1); P = 0.03).
CONCLUSION: There are no characteristic rotor-EGM potentials. Rotor-EGM characteristics are different between the RA and LA. Although rotors are not associated with abnormal EGMs, rotor-EGMs in persistent AF were more fractionated with lower amplitudes compared with that in PAF. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2015. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  Atrial fibrillation; EGM characteristics; FIRM mapping; Novel technologies; Rotors

Mesh:

Year:  2015        PMID: 26511397     DOI: 10.1093/europace/euv282

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  7 in total

1.  Safety and efficacy of persistent atrial fibrillation ablation using the second-generation cryoballoon.

Authors:  Kivanc Yalin; Amr Abdin; Evgeny Lyan; Noureddin Sawan; Spyridon Liosis; Christian Elsner; Alexander Jobs; Ben Brüggemann; Jelena Koester; Ingo Eitel; Charlotte Eitel; Roland Richard Tilz
Journal:  Clin Res Cardiol       Date:  2018-02-28       Impact factor: 5.460

2.  Integrating mapping methods for atrial fibrillation.

Authors:  Albert J Rogers; Mallika Tamboli; Sanjiv M Narayan
Journal:  Pacing Clin Electrophysiol       Date:  2018-09-09       Impact factor: 1.976

3.  Identification of active atrial fibrillation sources and their discrimination from passive rotors using electrographical flow mapping.

Authors:  Barbara Bellmann; Tina Lin; Peter Ruppersberg; Marit Zettwitz; Selma Guttmann; Verena Tscholl; Patrick Nagel; Mattias Roser; Ulf Landmesser; Andreas Rillig
Journal:  Clin Res Cardiol       Date:  2018-05-09       Impact factor: 5.460

4.  Arrhythmogenic propensity of the fibrotic substrate after atrial fibrillation ablation: a longitudinal study using magnetic resonance imaging-based atrial models.

Authors:  Rheeda L Ali; Joe B Hakim; Patrick M Boyle; Sohail Zahid; Bhradeev Sivasambu; Joseph E Marine; Hugh Calkins; Natalia A Trayanova; David D Spragg
Journal:  Cardiovasc Res       Date:  2019-10-01       Impact factor: 10.787

5.  Evaluation of the characteristics of rotational activation at high-dominant frequency and complex fractionated atrial electrogram sites during atrial fibrillation.

Authors:  Koji Kumagai; Kentaro Minami; Daisuke Kutsuzawa; Shigeru Oshima
Journal:  J Arrhythm       Date:  2016-07-13

6.  Initial experience with AcQMap catheter for treatment of persistent atrial fibrillation and atypical atrial flutter.

Authors:  M Liebregts; M C E F Wijffels; M N Klaver; V F van Dijk; J C Balt; L V A Boersma
Journal:  Neth Heart J       Date:  2021-10-26       Impact factor: 2.854

Review 7.  Regional Diversities in Fibrogenesis Weighed as a Key Determinant for Atrial Arrhythmogenesis.

Authors:  Cheng-Chih Chung; Chye-Gen Chin; Yung-Kuo Lin; Yao-Chang Chen; Wan-Li Cheng; Yung-Hsin Yeh; Yu-Hsun Kao; Yi-Jen Chen
Journal:  Biomedicines       Date:  2021-12-14
  7 in total