Literature DB >> 26509991

Influence of a Laser-Lok Surface on Immediate Functional Loading of Implants in Single-Tooth Replacement: Three-Year Results of a Prospective Randomized Clinical Study on Soft Tissue Response and Esthetics.

Renzo Guarnieri, Maurizio Grande, Stefano Ippoliti, Vincenzo Iorio-Siciliano, Francesco Riccitiello, Davide Farronato.   

Abstract

The purpose of the present prospective randomized study was to evaluate the influence of Laser-Lok microtextured surface on soft tissue peri-implant parameters and esthetics around immediate, functionally loaded implants for single-tooth replacement in the esthetic zone. This study included 77 patients divided into two groups based on different implants used: the control group had BioHorizons tapered internal non-Laser-Lok-type implants (NLL; n = 39) and the test group had BioHorizons tapered internal Laser-Lok-type implants (LL; n = 39). Outcome measures were survival, radiographic marginal bone-level changes, soft tissue parameters, and esthetics. One implant was lost in the test group and one in the control group, for a total survival rate of 96.1% after 3 years. Radiographically, mean crestal bone loss ± standard deviation was 0.59 ± 0.27 mm in the LL group compared with 1.17 ± 0.31 mm in the NLL group. A mean gain in papilla level of 0.41 ± 0.34 mm and 0.17 ± 0.36 mm was observed in the LL and the NLL groups, respectively, while the level of the midfacial peri-implant mucosa remained stable in both groups with no statistically significant differences (0.08 ± 0.42 mm for the LL group vs 0.06 ± 0.36 mm for the NLL group). The mean probing depth values in the LL and NLL groups were 0.58 ± 0.2 mm and 1.89 ± 0.3 mm, respectively. Within the limitations of this study, it was demonstrated that the clinical and esthetic outcome of immediate functional loading was more favorable for LL implants than for NLL implants.

Entities:  

Mesh:

Year:  2015        PMID: 26509991     DOI: 10.11607/prd.2273

Source DB:  PubMed          Journal:  Int J Periodontics Restorative Dent        ISSN: 0198-7569            Impact factor:   1.840


  10 in total

1.  Effectivity of homecare and professional biofilm removal procedures on initial supragingival biofilm on laser-microtextured implant surfaces in an ex vivo model.

Authors:  Gordon John; Frank Schwarz; Alexandra Kravchenko; Michelle Alicia Ommerborn; Jürgen Becker
Journal:  Int J Implant Dent       Date:  2021-05-21

2.  Immediate functional loading of single implants: a multicenter study with 4 years of follow-up.

Authors:  Filiep Raes; Tammaro Eccellente; Carolina Lenzi; Michele Ortolani; Giuseppe Luongo; Carlo Mangano; Francesco Mangano
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2018-03-14

Review 3.  Modifications of Dental Implant Surfaces at the Micro- and Nano-Level for Enhanced Osseointegration.

Authors:  In-Sung Luke Yeo
Journal:  Materials (Basel)       Date:  2019-12-23       Impact factor: 3.623

4.  Influence of Immediate Implant Placement and Provisionalization with or without Soft Tissue Augmentation on Hard and Soft Tissues in the Esthetic Zone: A One-Year Retrospective Study.

Authors:  Paolo De Angelis; Paolo Francesco Manicone; Giulio Gasparini; Silvio De Angelis; Margherita Giorgia Liguori; Ilaria De Filippis; Antonio D'Addona
Journal:  Biomed Res Int       Date:  2021-01-05       Impact factor: 3.411

5.  Changes in Maxillary Sinus Mucosal Thickening following the Extraction of Teeth with Advanced Periodontal Disease: A Retrospective Study Using Cone-Beam Computed Tomography.

Authors:  Zheng Cao; Jie Yuan
Journal:  Biomed Res Int       Date:  2021-03-23       Impact factor: 3.411

Review 6.  Effect of laser-microtexturing on bone and soft tissue attachments to dental implants: A systematic review and meta-analysis.

Authors:  Roodabeh Koodaryan; Ali Hafezeqoran
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2021-12-05

Review 7.  Implant-bone-interface: Reviewing the impact of titanium surface modifications on osteogenic processes in vitro and in vivo.

Authors:  Theresia Stich; Francisca Alagboso; Tomáš Křenek; Tomáš Kovářík; Volker Alt; Denitsa Docheva
Journal:  Bioeng Transl Med       Date:  2021-07-12

8.  Correlation between Buccal Bone Thickness at Implant Placement in Healed Sites and Buccal Soft Tissue Maturation Pattern: A Prospective Three-Year Study.

Authors:  Davide Farronato; Pietro Mario Pasini; Andrea Alain Orsina; Mattia Manfredini; Lorenzo Azzi; Marco Farronato
Journal:  Materials (Basel)       Date:  2020-01-21       Impact factor: 3.623

Review 9.  Biological and Chemo-Physical Features of Denture Resins.

Authors:  Gabriele Cervino; Marco Cicciù; Alan Scott Herford; Antonino Germanà; Luca Fiorillo
Journal:  Materials (Basel)       Date:  2020-07-28       Impact factor: 3.623

Review 10.  Human Papilloma Virus: Current Knowledge and Focus on Oral Health.

Authors:  Luca Fiorillo; Gabriele Cervino; Giovanni Surace; Rosa De Stefano; Luigi Laino; Cesare D'Amico; Maria Teresa Fiorillo; Aida Meto; Alan Scott Herford; Alina Vladimirovna Arzukanyan; Gianrico Spagnuolo; Marco Cicciù
Journal:  Biomed Res Int       Date:  2021-02-01       Impact factor: 3.411

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.