Jonathan M Williams1, Christopher Dorey2, Suzannah Clark2, Carol Clark2. 1. Faculty of Health and Social Sciences, Bournemouth University, Royal London House, Christchurch Road, Bournemouth, Dorset, BH1 3LT, UK. Electronic address: jwilliams@bournemouth.ac.uk. 2. Faculty of Health and Social Sciences, Bournemouth University, Royal London House, Christchurch Road, Bournemouth, Dorset, BH1 3LT, UK.
Abstract
OBJECTIVES: To investigate the between-day and within-day reliability of a sacral mounted accelerometer to quantify balance performance and different balance metrics. DESIGN: Experimental, cross-sectional. SETTING: Laboratorial experiment. PARTICIPANTS: Thirty healthy volunteers. MAIN OUTCOME MEASURES: Balance tasks were double leg stance, tandem stance and single leg stance with eyes open and closed. Performance was measured by converting accelerations into path length (PL, length of the sway trace), jerk (jerkiness of sway trace) and root mean square (RMS) of the accelerations. RESULTS: Within-day ICC for PL were excellent (mean 0.78 95%CI 0.68-0.89), with Jerk and RMS demonstrating means of 0.60 and 0.47, respectively. The mean percentage minimal detectable change (MDC) within-day were small for PL (mean 6.7%, 95%CI 5.3-8.1). Between-day ICC were good for PL (mean 0.61, 95%CI 0.50-0.71), but more varied for Jerk and RMS. The mean percentage MDC was small for PL (mean 6.1%, 95%CI 5.0-7.2). No significant differences were determined for measurements between-days for any metric or task. PL had the highest discriminatory value between the 8 tasks. CONCLUSIONS: The sacral mounted accelerometer reliably measured balance performance within- and between-days. The PL is the recommended metric as it was the most reliable, most discriminatory and most sensitive to change.
OBJECTIVES: To investigate the between-day and within-day reliability of a sacral mounted accelerometer to quantify balance performance and different balance metrics. DESIGN: Experimental, cross-sectional. SETTING: Laboratorial experiment. PARTICIPANTS: Thirty healthy volunteers. MAIN OUTCOME MEASURES: Balance tasks were double leg stance, tandem stance and single leg stance with eyes open and closed. Performance was measured by converting accelerations into path length (PL, length of the sway trace), jerk (jerkiness of sway trace) and root mean square (RMS) of the accelerations. RESULTS: Within-day ICC for PL were excellent (mean 0.78 95%CI 0.68-0.89), with Jerk and RMS demonstrating means of 0.60 and 0.47, respectively. The mean percentage minimal detectable change (MDC) within-day were small for PL (mean 6.7%, 95%CI 5.3-8.1). Between-day ICC were good for PL (mean 0.61, 95%CI 0.50-0.71), but more varied for Jerk and RMS. The mean percentage MDC was small for PL (mean 6.1%, 95%CI 5.0-7.2). No significant differences were determined for measurements between-days for any metric or task. PL had the highest discriminatory value between the 8 tasks. CONCLUSIONS: The sacral mounted accelerometer reliably measured balance performance within- and between-days. The PL is the recommended metric as it was the most reliable, most discriminatory and most sensitive to change.
Authors: Usman Rashid; David Barbado; Sharon Olsen; Gemma Alder; Jose L L Elvira; Sue Lord; Imran Khan Niazi; Denise Taylor Journal: Sensors (Basel) Date: 2021-12-25 Impact factor: 3.576
Authors: Andrew P Lapointe; Jessica N Ritchie; Rachel V Vitali; Joel S Burma; Ateyeh Soroush; Ibukunoluwa Oni; Jeff F Dunn Journal: Sensors (Basel) Date: 2021-06-30 Impact factor: 3.576
Authors: Bader A Alqahtani; Patrick J Sparto; Susan L Whitney; Susan L Greenspan; Subashan Perera; Jennifer S Brach Journal: BMC Geriatr Date: 2020-02-28 Impact factor: 3.921